Ranjith S.
Contact:+91-989*******, +91-959******* E-Mail:***************@*****.***
Site Construction& Engineering/ Project Management / Operations &Maintenance Industry Preference: Oil & Gas, Power Sector
ACADEMIC CREDENTIALS
Bachelor of Engineering Degree(B.E.,) in Electrical and Electronics Engineering from Periyar Maniammai University, Tamil Nadu, India with CGPA-9 & First class with Distinction. Additional Qualification:
Well versed with AUTOCAD, Electrical CAD & MS OFFICE Experience Summary
6+ Years of overall experience and 5 years of experience in Engineering& Construction (EPC in Oil Refinery, brown & Green field), 1 year of experience in Thermal Power Station. Maintenance and Testing (Thermal Power Station) in Major Electrical Substations, Power system, lighting system, Earthing system, Cathodic Protection System, EICS/ Telecom (Enterprise Integrated Communication System), EHT (Electrical Heat Tracing) and SECT systems.
Skills & Strength
Planning, Scheduling, Coordination and Execution.
KNPC Authorized gas tester, Work permit Issuer & Executor for CFP Project.
Well versed with KNPC Procedures and specifications.
Configuration and troubleshooting of pelco Outdoor Ex-type CCTV camera’s.
Fault identification and Testing of Cables, Transformers, Switchgears, AC/DC UPS, Fire alarm, CT and PT etc.
Installation of Electrical equipments such as package substation, transformer and diesel Generator.
Trouble shooting, preservation and maintenance of Transformer, Switch gear, Motor etc.
Installation and Commissioning of Cathodic Protection system such as
Sacrificial Anode Cathodic Protection for U/G piping, fire hydrant, Road Crossing U/G piping
Impressed Current Cathodic Protection for Tank external, U/G piping (Deepwell Anode Installation and
Surface Bed Anode Installation)
Installation of EICS system equipments such as
PCS (Plant Communication system, Industronics & gaitronics)& PEAS (Plant Emergency Alert System, Bosch) which includes, Speaker, Amplifiers, Handset, Beacon, Hotline, CCTV& IP Telephone.
Installation of fire alarm system, Lighting, Grounding systems.
Installation of Heat tubes, Field JB, Distribution box for Electrical Heat Tracing system (EHT)
Excellent communication skills and firm believer in teamwork.
A dynamic professional with over a year of experience in Electrical Maintenance of Motors, Meter Relay Testing, Turbine Generator Maintenance & Switchyard.
An effective communicator with excellent relationship building & interpersonal skills with strong analytical, problem solving & organizational abilities. Possesses a flexible & detail oriented attitude. Detailed Work Experience
Jan 2020–Aug 2020
JGC (JCON), CFP Project, KNPC Kuwait
JV Telecom & Electrical Engineer
Project Profile: “Clean Fuels Project” KNPC, MAA Refinery, Kuwait Job Responsibilities:
Commissioning of Cathodic Protection system which involves Sacrificial Anode installation type for U/G piping, fire hydrant and Impressed Current Cathodic protection for Tank External& Internal, Concrete rebar, U/G piping
(Surface bed anode installation) in New Areas.
Commissioning & Troubleshooting of Remote Monitoring System in Cathodic Protection System.
Configuration & trouble shooting of PELCO Camera’s & PEAS bosch systems in existing KNPC MAA refinery.
Troubleshooting CCTV F&G interface, Encoder, NSM and CCTV field related issues.
Conducting CCTV, PEAS, PCS & PMRS SAT along with company and coordinating for punch closing activities.
EICS system installation such as PEAS (Plant Emergency Alert System), PCS (Plant Communication system) including CCTV, Beacons, Handset (Gaitronics & Industronics) and IP Telephone.
Modification of Existing Gaitronics & Industronics PCS cabinet (Addition of new field devices) and extension of existing handstation.
Configuration of BDA’s in Band selective & Channel selective radio system in Tetra. Oct 2015– Oct 2019
GS E&C, CFP Project, KNPC Kuwait
Electrical Supervisor
Project Profile: “Clean Fuels Project” KNPC, MAA Refinery, Kuwait Job Responsibilities:
Installation, Testing and Commissioning of new motors (HV & LV), diesel generators, Distribution panels and MCC’s (New & Tie-in) in Revamping Areas.
Installation and Commissioning of Cathodic Protection system which involves Sacrificial Anode installation type for U/G piping, fire hydrant and Road Crossing U/G pipe (Casing & carrier protection) and Impressed Current Cathodic protection for Tank External, U/G piping (Deep well Anode Installation which depth 48m and Surface bed anode installation) in Revamp Areas.
Cable laying (11KV, LV, Control cable and FO cable), Glanding & Termination of Electrical & FO cables for related panels like MV, LV, Control & Auxiliary panels, Marshalling Cabinet.
Splicing of power cables (1C 630sqmm, 1C 300sqmm), Control cables (7C 2.5sqmm) and FO cables (6C SMFO, 24C SMFO& 72C SMFO).
Installation Cable trays such as ladder type trays, perforated type trays in new and revamp areas for lighting & power systems.
Lightning & Earthing system installation for newly installed equipments and relocation of existing facilities.
Preparation and review of WMS, RA and MAR for all Electrical Activities.
Planning and Scheduling of overall electrical activities in brown revamp areas.
Installation of Lighting fixtures/ lighting poles and power sockets.
EICS system installation such as PEAS (Plant Emergency Alert System), PCS (Plant Communication system) including CCTV, Beacons, Handset (Gaitronics & Industronics) and IP Telephone.
Modification of Existing Gaitronics & Industronics PCS cabinet (Addition of new field devices) and extension of existing handstation.
EHT Installation for Sulphur line along with Field JB’s, Power Kit, Power Distribution box and tubes.
SECT Cable pulling, Transformer installation & field JB installation, Self regulating cable installation of Bitumen line.
Nov 2013 – Nov 2014
Tamil Nadu Electricity Board (North Chennai Thermal Power Station) Graduate Engineer Apprentice Trainee
Highlights
Switch yard
o Maintenance of 230KV Indoor Switchyard Equipments Such as: o Power Transformers, Wall through Bushings, Current Transformers, SF6 Circuit Breakers, Capacitance Voltage Transformers.
Meter Relay Testing
o Tested and maintained of Power plant Equipments such as: o Power Transformers:15.75 /230 KV, 15.75/6.6 KV&6.6 KV/ 440 V (Capacity: 250MVA, 50MVA&16MVA, 2MVA).
o 230 KV - SF6 Circuit Breakers, CT’s, and CVT’s.
o Battery: 220v, 110v & 30v Lead Acid, Ni CD Battery and Battery chargers. o Electro Magnetic and Static Relays of Over & Under Voltage. o Motor Protection Relays.
Turbine Generator Maintenance
o Electrical Maintenance of Generator &
o Stator Water Cooling
o Rotor H2 Cooling
o Seal oil Maintenance
o Separation and Compression of H2 gas from Water. Roles and Responsibilities
• Preparation of site activity plans in the detailed project schedule.
• To review the planned activities and confirm the actual resources including the human, equipment, plant, documentation, work method and sub-contractor as applicable during the site planning stages.
• Daily and long term planning at site, coordination, control and efficient utilization of the required resources for all site activities.
• Coordination with QA/QC Engineer in receiving and inspection materials at site and generation of material receiving records.
• Coordination with QA/QC Engineer in reporting and disposition of NCR’s at site.
• Coordination with Safety Engineer for the safety arrangements at site prior to start any activity at site.
• Reconciliation of all markup drawings needed for As-built drawing generation.
• Arrange proper handling and storage of materials/equipment at project site.
• Regular review/progress meeting with the project team, sub-contractor personnel on the actual current site execution status and plan for the required resources to meet the project target schedules/plans.
• Overall coordination with the sub-contractor at project site.
• Coordination with client representative on inspection/test witness and any other contractual obligation.
• Monitoring & control of the relevant company procedures to ensure that they are followed correctly. Rectify and implement any deficiencies reported by the client or QA/QC Engineer. Overall coordination with QA/QC Engineer, all other engineers working at project site.
• Coordination of all requests for inspection at site and arrangement for inspection and testing at various stages.
Monitoring, progress certifications, formal reporting and documentation including quality control of the execution of the work in accordance with the procedures and requirements. Academic Summary
Degree Year Institute
Board/
University
Percentage/
CGPA
B.E (Electrical and
Electronics
Engineering)
2009 ~ 2013
Periyar
Maniammai
University
Periyar
Maniammai
University
9.00
HSC 2009
Sri Ramakrishna
Mission vidyalaya
boys hr. Sec.
School
State board 71.75%
SSLC 2007
Sri Ramakrishna
Mission vidyalaya
boys hr. Sec.
school
State board 75.4%
Achievements:
Presented a Paper on ‘BIO FUEL FROM ALGAE’ at 15th ISTE Conference in Sanjay Ghodawat Institute, kohlapur, Maharashtra.
Won 3rd Price in Poster Presentation (BIO FUEL FROM CHICKEN FEATHER MEAL) at Anna University, Trichy.
Won 2nd Price in Poster Presentation (BIO FUEL FROM ALGAE) at GCT, Coimbatore.
Exhibitedprojects in OPEN HOUSE 2011 & 2012 in Periyar Maniammai University, Thanjavur. (Water level Indicator, Solar Power Utilization, Solar Irrigation system, IR Home Automation, LED Technology)
I have completed my PLC training in Arista Technical Solution, Chengalpattu.
Completed Autocad & Electrical CAD in CADD centre chengalpattu. Other Information
PERSONAL DETAILS:
Date of Birth: 29August1992.
Linguistic Skills: Tamil, English & Hindi.
Marital Status: Married.
Nationality: Indian.
Passport No.: T2733327 (Expiry Date: 12/03/2029).
Permanent Address: 450/1 Bethel Nagar, Alapakkam, Vallam post, Chengalpattu – 603002, Tamil Nadu. Declaration:
I hereby declare that the particulars given herein are true and complete to the best of my knowledge and belief. Place: Chengalpattu
Date: 22 Feb. 21
Kind regards,
(RANJITH.S)