PREM KUMAR SINGH
Vill- Amorha, Post- Uruwa Bazar, Dist- Gorakhpur, Pin- 273407,
Email: adiukm@r.postjobfree.com, adiukm@r.postjobfree.com Skype id: adiukm@r.postjobfree.com
Mob: 0091-909-***-****/945-***-****
QC CHEMIST
Multi-certified technology professional with experience managing enterprise implementations of laboratory information and Spectroscopy systems. Expert in gathering, analyzing and defining business and functional requirements, workflows and technology solutions for laboratory systems. Proven ability to lead seamless implementations and deliver next-generation technical solutions improving revenues, margins and workplace productivity. Good working experiences in modern equipments, machines and facilities used for processing of various experiments for Petrochemical, Water and Essential Oil in a modern laboratory.
Educational Qualification
NAME OF EXAM
NAME OF BOARD / UNIVERSITY
YEAR OF PASSING
SUBJECT
H.Sc.
UP Board, Allahabad
1990
Science (Phy, Chem, Math)
B.Sc.
Pt. D.D.U.Gorakhpur University
1998
Chemistry
M.Sc.
VBSP University Jaunpur.
2001
Chemistry (Organic)
Total Experience 14 Years (Petroleum & Oil Refinery)
Professional Experience
1.GSPC LNG – Mundra, Gujarat. Oct. 2020 to Present.
Lab Chemist:- LNG Sampling System (Make IMTEC),Analysis of Natural Gas in Gas Chromatograph (Make- Perking Elmer Clarus- 580)
2.Cairn India Ltd. – Ahmedabad, Gujarat. July 2014 to June 2020.
Lab Chemist:- Work as TPC employee of Cairn Energy Ltd.in Midstream.(Oil Exploration)
3.HPCL – MITTAL ENERGY LTD (HMEL) – BATHINDA, PUNJAB March 2012 to July 2014 .
Lab Chemist
Work as contractor employee of Aarvie Encon Pvt. Ltd. in Guru Gobind Singh Refinery.
4.GAIL (India) Ltd. Gandhar Bharuch Gujarat. Aug. 2005 to March 2012.
Lab Chemist
Routine analysis of gas sample viz. LPG, Rich gas, Semi Rich gas & Lean gas in Gas chromatograph (make-Agilent 6890 Series.)
Analytical Experience
Petroleum Analysis
Raw material: - Crude Oil
Refinery Finished Product: - LPG, Naphtha, Motor Gasoline, SKO (Superior Kerosene Oil), HSD (High Speed Diesel), ATF (Aviation Turbine Fuel) & Pet Coke etc.
Refinery Process Samples: Process samples to analyze from CDU, VDU, FCCU, DHDT, VGO-HDT, DCU, NHT, CCR etc.
Parameters:-Find out the following chemical and physical parameters for Dispatch, Export oil and frequently checking the quality of Refinery Finished Products. These are Distillation, Kinetics’ Viscosity, Flash Point (Able, PMCC), Moisture, Color, Vapor pressure, Gum Content, Carbon Residue, Oxidation Stability, Acidity, Density, Smoke Point, Sulphur, Hydrogen Sulphide, Cloud Point, Pour Point, Freezing Point, BS & W, Mercaptans, Bromine No., Bromine Index, Total Acid No.(TAN), Copper Corrosion, Silver Corrosion, Florescent Indicator Absorption (FIA), Sulphur Test, Aniline Point, Doctor Test,HGI,GCV(bomb Calorimeter), Volatile Matters etc.
All samples are Analyzed As per ASTM, IP, UOP, ISO and BIS methods.
Water Analysis: -
Utility Samples:- Utilities Samples to analyze from Boilers, Furnace boilers, DM Plant, Effluent Treatment Plant, Sewerage Treatment Plant, Cooling Towers, Distillation and RO Plants in Processing Units, Fire Reservoir Pond Water, etc.
Process Samples: - Brine water, Boot water, Diesel Product Steam Generator and sour water.
Parameters: - pH, Conductivity, TDS, TSS, COD, BOD, Alkalinity, Chloride, Color, DO, Hardness, Hydrogen Sulphide, Iron, MLSS, MLVSS, Ammonia, Oil and Grease, Phenol, Phosphate, Silica, Sulphate, Sulphide, Turbidity, etc.
Preparing and standardizing Analytical Solution and reagents for testing.
LIMS (Laboratory Information Management System).
LIMS Version 5.6:- Based on oracle and Windows NT.
Total operation of LIMS: - Sample Logging, Results entry, validation the results, & Result data generation.
SAP based Laboratory Analysis result reporting.
Also involved in Calibration of Instruments, Standardization and generate product certificates.
I am ready for possess multi skill for the present operation and shall be ready to carry out multidisciplinary task, if requested.
Instrumental Experience
As a lab Chemist, I Know Operation of these instruments:-
UV-Vis spectrometer (Shimatzu UV – 1800 & Hach DR – 2800 & 2700),Potentiometric Titration (Mettler Toledo), Distillation (Herzoq OptiDist), ED-XRF (Merck), Oil Centrifuge (SETA), Viscometer (Anton Paar SVM 3000), Density Meter (Anton Paar DMA 4500M), Aniline Point Control Unit (Tanaka), Existent Gum Solid Block Bath (SETA), Reid Vapour Pressure Tester (SETA), Flash Point Pansky Martin Closed Cup (PMCC), Karl Fischer Tetrameter (Mettler Toledo), Weighing Tool (Mettler Toledo), Essential oil Distillation unit, etc.
Workshop and Seminar Attended
I have attended the training on SAP/ERP given by IBM and GAIL ERP Department.
I have attended the training on FIRST-AID in GAIL (India) Limited, Gandhar.
I have undergone Fire & Safety training in M/s GAIL (India) Limited, Gandhar. Also well conversant with different types of fire extinguishers
Passport Detail
PASSPORT NO. : V – 0331830
PLACE OF ISSUE : LUCKNOW
DATE OF ISSUE : 20.08.2020
DATE OF EXPIRY : 19.08.2030
References
1. Mr. P.K. Mall Manager, Laboratory
HPCL-Mittal Energy Limited - Bathinda, Punjab
Email: adiukm@r.postjobfree.com
I hereby declare that the above information and particulars are true and correct to the best of my knowledge and belief.
(Prem Kumar Singh)
Now you can upload your resume directly to Monster using Word 2007!
1.Install Monster’s Easy Submit add-in by clicking the “Install” icon on the menu ribbon.
2.Once installation is complete, restart Word.
3.Click on the “Upload” icon to upload your resume to Monster.
For any issues or questions, please visit the Easy Submit installation support page.
To close this reminder, click the border and then press DELETE.