Post Job Free

Resume

Sign in

Maintenance Plant

Location:
Salem, Tamil Nadu, India
Posted:
December 13, 2020

Contact this candidate

Resume:

M.Manikandan,

*/***, ********** **** ******,

Sanniyasigundu (PO), E-MAIL ID : adinjd@r.postjobfree.com

Salem – 636015 CELL NO : 995**-*****

OBJECTIVES :

To embrace a challenging task where I can apply all my innovative thoughts with enthusiasm in empowering the organisation

CURRENT WORKING :

• Company : Sakthi Auto Component Ltd,Pallagoundanpalayam-56

• Designation : Company Apprentice

• Job location : Foundry Electrical Maintenance

• Duration : 28th January 2016 To Till Now(3 years +)

CARRIER SUMMARY :

• Preparation and Implementation of Preventive maintenance works in DISA Foundry Machineries. Analysis on break down and implementation of corrective action plan for above.

• Monitoring and Controlling the critical parameters of Electrical equipment’s with in permissible limits to avoid break down.

• Monitoring and Implementation of Electrical Safety system based on safe operating procedure training and internal audits

ACADEMIC QUALIFICATION :

Qualification

University/Board

Institution

Year of passing

Aggregate

B.E(EEE)

Anna

university,

Chennai

KSR Institute for Engineering and Technology

2015

6.64

HSC

State board

Bharathi Vidyalaya Higher Secondary School

2011

75.75%

SSLC

State board

National High School

2009

89.8%

WORKING RESPONSBILITIES :

• Controlling and Maintaining of PLC based SFC for Medium Frequency Induction Furnace plant [3000KW, 250HZ, 5 Ton Capacity, ABB make].

• Controlling and Maintaining of Cupola Furnace [16 Ton Capacity].

• Operation and Maintenance of PLC Based Machineries [Allen Bradley PLC, SIEMENS PLC, & DELTA PLC].

• Automatic Metal Pouring ABB and FOMET Press Pour [7 Ton capacity].

• Operation and Maintenance of DISAMATIC High Pressure Moulding Machine & DISA Sand Plant.

• Operation and Maintenance of Dust and Fumes Collector & Compressors [540 CFM & 220CFM].

• Operation and Maintenance of Distribution Transformers up to 2 MVA and Furnace Transformers up to 3.6 MVA.

• Operation and Maintenance of pneumatic and vacuum system using solenoid valves, cylinders (linear, rotary), actuator (SMC /FESTO), vacuum pumps etc.

• Parallel operation of 11kv Diesel Generator & power transformer.

• Operation and Maintenance of 110/11kv, 12.5MVA Power Transformer.

TROUBLE SHOOTING :

• Trouble shooting of AC DRIVES and electrical control circuits with DOL, STAR DELTA, Magnetic Contactors, relays, timers etc.

• Trouble shooting of EOT cranes like that MUKUND, DEMAG, GRIP, FEFFECO Makes.

• Trouble shooting overhauling and preventive maintenance of single/three phase induction motors, and AC/DC servo motors.

• During the Maintenance time checking the Motors and Pump house working condition like as Vacuum, Peristaltic, Velton, and centrifugal Pump.

• Checking the equipment condition in N2 and O2 plant side like as Heaters, valves and Freezing unit.

• Experience in various types of Pressure and Limit switches, various types of Sensors like Inductive Proximities, Magnetic, Temperature, Level Sensors and various types of Transducers and Factory supply Maintenance.

PREVENTIVE MAINTENANCE

• Weakly once checking the equipment condition like that Motors terminals, smooth operation, and cable condition etc.,

• Frequently checking the safety limit and Speed Monitoring sensor.

• Continuously checking the Belt conveyor and chain conveyor Pull Guard rope, sway switch condition, Rotation Guard Sensor condition and inter locking condition etc.,

• During the plant maintenance time checking the Solenoid Coil,LVDT,Proximity Sensors, Encoders and Servo Motor etc.,

• In inductor side frequently checking the Coil Temperature and cooling water Pressure.

• Monthly once checking the Fuse condition in Isolator, FDB and SSB side up to 800A fuse rating.

INSTALLATION & DOCUMENTATION

• Cable laying from panel side to equipment side with all type of cables like that Flexible, Armour, Screened cable also.

• Can work in control room falls ceiling wiring and plant lighting also.

• Evaluated PO and PR documents and documented all technical specifications for equipment and processes.

• To calculate daily power consumption every hours taken readings [Power Factor, Voltage, Current, and KWH].

• Making reports of Plant Machinery also looking for TS/ISO/IATF Audit documents.

• To prepare daily to daily work report under to save the setting and manpower adjustment and circuit diagrams.

PERSONAL QUALITIES

• Think always positive

• Make joyful around me

• Coordinate with others easily

ACADEMIC PROJECT

GSM based pre-fault determination of a transformer in power system

PAPER PRESENTATION:

Presented a paper on “Wind Energy” in Intra Departmental paper presentation organized by KSR Institute for Engineering and Technology,Tiruchengode.

Presented a paper on “Human as an Electric Generators” organized by VSA School of Engineering,Salem.

INPLANT TRAINING:

Attended the training at “BSNL”,Salem for 5 days.

Attended the training at “MTPS”,Mettur for 5 days.

TECHICAL SKILLS:

Matlab PCB Design and Fabrication

NI Multism

PLC

PERSONAL PROFILE

Name : M.Manikandan

Fathers Name : P.K.Mani

Mothers Name : M.Vijiya

Date of Birth : 24-03-1994

Languages Known : Tamil, English [Read, Write & Speak],Telugu (Speak)

Hobbies : Playing Cricket,Carrom

DECLARATION

I hereby declare that the above mentioned details are true to the best of my knowledge.

Place: Sincerely,

Date: [M.MANIKANDAN]



Contact this candidate