Post Job Free

Resume

Sign in

Engineer Power Plant

Location:
Dubai, United Arab Emirates
Salary:
1lakh rupees per month
Posted:
December 11, 2020

Contact this candidate

Resume:

S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

CURRICULUM VITAE

Name: VIGNESH SUBRAMANIAM LOGANATHAN

Position: Testing & Commissioning Engineer-Power system (Approved by Dubai & Sharjah Electricity Authority)

Experience: 7+ Years (3+ Years in UAE)

Nationality: Indian

License: Valid UAE Driving License.

CARRIER SUMMARY:

• Testing & Commissioning of Power System Unit up to 400Kv. (Generators, Motors, CT, VT, Protection Relays, Breakers, Busbars, Cables, Transformers etc.)

• Can satisfy the customer requirements as per the site condition.

• Can work independently & be a very good self-starter with good team orientation.

• Coordinating with the other sub-contractors and end clients for the smooth work progress.

• Manage and oversee the day to day progress of the project.

• Supervise team members to give everyone a task and remain in loop to ensure the progressing of the project as planned.

S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

VIGNESH SUBRAMANIAM LOGANATHAN

Contact No: +971-**-******* (UAE)

+91-950******* (INDIA)

E-Mail: adiksk@r.postjobfree.com

Objective:

• I am a 7+ Years experienced Bachelor of Electrical & Electronics Engineer looking for an opportunity, to be a part of a highly motivated team and achieve challenging position in Electrical Field.

• To utilize my knowledge and experience in the field of Installation, Testing, commissioning where I can contribute to the organization’s success with my sincere efforts and at the same time, would like to expand my knowledge base and people skills in a highly professional team environment. Professional Experience: : 7+ years (3+ Years in Dubai)

From FEB 2017 – TILL DATE: M/S ACUME ELECTRICALS (DUBAI) Designation: Power System Engineer.

From NOV 2013 – OCT 2016: RESONANCE POWER SYSTEMS PRIVATE LIMITED. Designation: Power System Engineer

Educational Qualification:

: Bachelor in Electrical and Electronics Engineering (B.E - EEE)

: Cape Institute of Technology, Levengipuram.

Under Anna University Chennai

: With 6.62 CGPA & First Class (Year of completion: 2013).

: Diploma in Electronics and Communication Engineering (DECE)

: Surya Polytechnic College, Kanyakumari dist.

Under DOTE. Tamil Nadu

: 88% & First Class. (Year of completion: 2010).

COMPUTER SKILL SET:

Packages: AUTO CAD, PRIMAVERA

S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

OVERSEAS PROJECT EXECUTED ACTIVITIES (for all sites mentioned Below) 1. Auxiliary relay Test,

2. CT, VT Test,

3. Get certification of Relays commissioning checks for test charging as per test formats. 4. Protection scheme checks, Back up relay testing, 5. DC outgoing cable checks,

6. Main Relays testing coordination with manufacturer. 7. Differential relay, Loss of excitation, Reverse power protection, unbalance voltage relays testing. 8. Primary injection & Secondary injection of CT’s in 11Kv,132Kv,220Kv & 400Kv 9. Trip circuit supervision checks

10. VT secondary injection test,

11. Busbar stability and sensitivity test coordination. 12. Coordination with customer regarding scheme modification for relay retrofitting. 13. Protection activities such as primary injection of CT circuits, sensitivity and stability of Bus Bar protection, transformer stability, trip logic tests. 14. BCU retrofitting modification and stimulation of interlocks and signals As FAT Co-ordination Engineer in M/s. ALSTOM

EXECUTED ACTIVITIES:

1. Panel Physical checks and Quality checks

2. Scheme checks as per the approved scheme and preparing the red markups If required.

3. IR and HV test.

4. AC / DC voltage checks as per the scheme

5. Auxiliary relay tests and Backup Numerical relay checks 6. FACTORY ACCEPTANCE TEST (FAT) offering to the clients. PROJECT PROFILE:

Overseas Experience:

1. Client: Petrofac. Project inside Drydocks.

Project: 66KV GIS component Testing.

2. Client: DUBAI AIRPORTS. Project inside Dubai Airports. Project: Differential relay and its relevant circuit modifications & Relay testing 3. Client: SHUAA ENERGY. Project near Solar innovation center. Project: 132/33kv MBR SOLAR PHASE 3 Substation (Phase-A) S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

4. Client: SHUAA ENERGY. Project near Solar innovation center. Project: 132/33kv MBR SOLAR PHASE 3 Substation (Phase-B) 5. Client: M/s. ELEMEC (FAT Verification). Project office at Dubai Investment Park. Project: HAYATT CENTRIC Private Site.

6. Client: M/s. GE. Project office Sharjah.

Project: 132/11KV HAMRIYA POWER AND DESALINATION PLANT,

(Adding of new 220kv GIS in existing Substation) For Sharjah Electricity & Water Authority (SEWA) 7 Client: M/s. GANTHOOT. Project office at Dubai.

Project: 132/11KV QUASIS Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376*******

8. Client: M/s. MITSUBISHI ELECTRIC CORPORATION. Project office at Dubai. Project: 132/11KV WHEIDA Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376********

9. Client: M/s. L&T, Project office at Dubai.

Project: 132/11KV GARHOUD Substation, For Dubai Electricity & Water Authority (DEWA) 10. Client: M/s. MITSUBISHI ELECTRIC CORPORATION, Project office at Dubai. Project: 132/11KV EMRDVLAS Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376*******

11. Client: M/s. ABB, Project office at Dubai.

Project: 132/11KV MAADEN Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376*******

12. Client: M/s. ABB, Project office at Dubai.

Project: 132/11KV MAJAN Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376*******

13. Client: M/s. ABB, Project office at Dubai.

Project: 132/11 KV VLGNDHMR Substation, For Dubai Electricity & Water Authority (DEWA) Contract No: PO 376*******

14. Client: M/s. BEC, Project office at Dubai.

Project: 132/11 KV BHAR JUMEIRA Substation, For Dubai Electricity & Water Authority (DEWA) S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

15. Client: M/s. ALSTOM, (Panel Readiness for FAT Verification), Project office at Sharjah. Project: 400/220/132/11KV QATAR PHASE 12 – Lusail, West 1, West 2, WBTS, DSS For QATAR GENERAL ELECTRICITY AND WATER CORPORATION (KAHRAMAA) PROJECTS COMPLETED ALL OVER INDIA:

EXECUTED ACTIVITIES:

1. 400KV SWITCHYARD at PGCIL Gujarat. Client: BHEL

Testing and Commissioning of all Switchyard equipment, Control Relay Panel, Interlock Logic Check, Primary injection of Bus & Bay, Busbar Differential, Differential Stability of 125 MVAR, Banaskantha District, Gujarat.

2. ONGC at Surat, Gujarat. Client: L&T EBG

Testing and Commissioning of all LT equipment such as CT, PT, ACB, Scheme Checking, Interlock Logic Checking,

3. SAIL at Bhilai, Chattisgarh. Client: L&T EBG

Scheme modification of 6.6 KV Panel as per the customer requirement, Testing of Vaccum Circuit Breaker of ABB make, Commissioning of 6.6 KV panel after Scheme & Interlock logic checking.

4. Jindal Steel & Power Limited, Odisha. Client: L&T EBG

Testing & Commissioning of 33 KV, 11KV & 6.6 KV Switchgear equipment and Panel, Hipot test on cable, Scheme checking of Panel,

5. Maharaja Shree Umaid Mills Limited at Pali, Rajasthan. Client: ABB

Testing & Commissioning of 132KV Switchyard, 11 KV Switchgear and Panel, Control Relay Panel, Scheme Checking, Interlock logic Checking.

6. Jaiprakash Power Ventures Limited. Allahabad, Uttar Pradesh. Client: L&T EBG

Testing & Commissioning of 415V LT panel, LT & HT Motors, Hipot Test on HV cable. 7. Adani Port. Mundra, Gujarat. Client: L&T EBG

Commissioning of CHP (Coal Handling Plant), HT & LT Substation, Testing of Auxiliary Relays and Numerical Relays such as Feeder Protection Relays

8. SAIL at Durgapur Power Evacuation System for 2X20 MW Power Plant. Client: L&T EBG

Testing & Commissioning of 33 KV, 11KV & 415V Switchgear equipment and Panel, Hipot test on cable, Scheme checking of Panel, Testing.

Relays tested:

Numerical Relays

ABB REF 615, REV 615, REL 670, REF620, REL60 - Feeder protection S.L.VIGNESH CURRICULAM VITAE adiksk@r.postjobfree.com

+971-********* (UAE)

MICOM P14N, MICOM P14D – Feeder protection

SEL751A,SEL351, - Feeder protection

SIEMENS 7SJ602, SIEMENS 7ss52 - Feeder protection

SEG Make-Differnetial,EF,O/C protection

Auxiliary Relays

MVAJ105, MVAJ051, MVAJ053, MVAX12, MVAX31

Test Kit Used:

OMICRON CMC 356,256,156, OMICRON CT ANALYZER.

FREJA 300

SVERKER 760

PRIMARY INJECTION KIT (ODEN)

CRM, TIMER

DC POWER BANK

HV KIT, DLRO

CPC 100

Personal Details:

Father Name: S.Loganathan

Date of Birth: 30th March 1991

Nationality: Indian

Languages know: English, Hindi & Tamil

Marital Status : Single

Permanent Address: 15/19-A, Thanumalayan Nagar, Suchindrum, Pin-629704, Tamilnadu, INDIA. Passport Details

Passport Number: K8971932

Date of Expiry: 18/12/2022

DECLARATION

I hereby confirm that the information given in this form is true to the best of my knowledge and belief

VIGNESH SUBRAMANIAM LOGANATHAN.



Contact this candidate