Avadhesh Tiwari
: adfzr2@r.postjobfree.com
Extensive experience of 12+ year in Operation & Maintenance, Erection & Commissioning, Projects management, Overhauling Testing in Control and Instrumentation with organizations of high repute. CORE COMPETENCIES
Functional Skills
Operation & Maintenance
Projects management
Overhauling Testing
Commissioning
Site Management
Quality Assurance
Safety Management
Vendor Development
Team building & ownership
Various DCS proficient
Spares and manpower management
Problem-solving & Decision-
making
PROFILE S UMMARY
Proficient in managing Operation & Maintenance, Installation and commissioning, Overhauling testing, EPC up to 660 MW unit plant in the field of Instrumentation.
Technical discussion and development of logics and interlocks for power plant and their implementation in Honeywell DCS Experion C300 .
Interlock and protection checking of Boiler management system (FSSS), auto control loops and CCS, ETS.
Working experience in PLCs (AB,SIEMENS,MITSHUBISHI)
Experience in managing overall maintenance for enhancing operational effectiveness of equipment.
Expertise in proactively identifying & resolving C&I problems in minimum time to reduced downtime of running equipment.
Experience in FAT and SAT inspection. Finalization of OLCS and CLCS in SAMA logics later there implementations.
UPS & batteries commissioning and maintenance up to 80 KVA
Good knowledge of international standards and practices.
SAP knowledge
JOB KNOWLEDGE
DCS Commissioning & Maintenance
Honeywell DCS- TDC 3000 & EPKS C300 & SM SIL3
Yokogawa Centum CS3000
Emerson Ovation OCR 400
GE OC 4000
Foxboro Invensys CP40
PLC programming
ALLEN BRADLY
SIEMENS
TSI (Bentley & Rockwell instruments)
Installation and commissioning of vibration pickups, speed probe.
Installation and commissioning DE probes, RP, ECC and axial shift probes. Maintenance of actuators (Auma, Bernard,Abb,Back, Rotark,AI/MI)
Installation and commissioning.
Troubleshooting.
Special Instruments:- Analyzers (O2,H2&DO),CEMS-SOX,NOX,Opacity Mass flow meter, Ultrasonic TX, Ramsey and Siemens coal flow integrators, Fishers, Masolelian and SMC Pneumatic Controllers.TSI instruments calibration, PH& Conducting analyzers.
ORGANIZATIONAL EXPERIENCE
Since April 2011 with Vidarbha Industries Power Limited (Reliance Power Limited), Nagpur, M.S. As Sr. Manager Instrumentation
BTG Design & Supply with Shanghai Electric Power Corp. China.
Responsible for maintenance, availability and spare management of BTG including CW pump house, fuel oil and DM plant & being a part of the CPP maintenance Team.
Have done DCS Commissioning with Honeywell/SPERI Engineers.
Responsible for Maintenance and calibration and availability of Control Valves, Smart actuators, Electronic/Smart Transmitters, Gas Analyzers and other available instruments.
Field Fault diagnosis and online necessary logic modification
Responsible for Vendor development for BTG System.
Responsible for the implementation and documentation required for SAP.
Responsible for capable of developing checklist and commissioning documents.
Have done Erection & Commissioning of of Boiler Burner Management System,DEH,ETS and HP bypass System Since Dec 2009 to April 2011 with WPCL, Warora (KSK Energy Ventures Limited),Maharashtra As Assistant Manager
Commissioned of boiler FSSS i.e. gun, flame scanner, fans, and mill.
Commissioned boiler instruments which includes mainly flame tv camera, control valves, hydra step, drum level gauge glass, oxygen analyzers, SADC actuators,APH leakage detecting system.
Commissioned Feeder instruments which include mainly Siemens Coal flow integrator BW500 and VFD MM440.
Commission of Turbine supervisory instruments which includes 8 speed pick up, two expansions, two casing expansion, 3 axial pick up, 10 shaft vibration and 5 bearing vibration.
Commission of DEH system, which includes 6 governing valves and four stop valves 28 sov and 6 ehsv.
Commissioning of DCS GE OC4000 system.
Responsible for protection and interlock checking of Unit I & II.
Responsible for O&M services contract finalization of KPS for BTG area and Chennai radha for BOP area.
Responsible for day to day O&M activities and also modification, punch point Since June 2007 to Dec 2009 with Bharat Aluminium Company Ltd(BALCO) Korba,C.G. As Assistant Manager
Participated in 4 major annual over hauling of the plant
Commissioned PA fan of 250 kw capacity
Responsible for maintenance, availability and spare management of All Units including CW pump house, fuel oil and DM plant FGC being a part of the CPP maintenance Team.
Responsible for Maintenance and calibration and availability of Control Valves, Smart actuators, Electronic/Smart Transmitters, Gas Analyzers and other available instruments.
Field Fault diagnosis and online necessary logic modification.
Responsible for Honeywell system administration by maintaining System security and backup for smooth running of DCS system and AB plc.
Responsible for the implementation and documentation required for SAP.
Zone leader in 5S for DM plant area.
Associated with maintenance contractor for Preventive maintenance schedule and manpower planning.
Documentation for Certification Audits for the ISO standards
Supported the operation team in more than 25 startup individually which includes cold, hot and warm start-ups EDUCATION
Year
Institution Program Percentage 2003-2007 J.E.C. Jabalpur
Bachelor in Engineering
(Electronics & Communication)
71.4
2002 Govt. Model H. S. School, Jabalpur. H.S.S.C. (12th) 75.5 2000 Govt. Model H. S. School, Jabalpur. H.S.C. (10th) 79.6 TRAININGS
Received training at Foxboro Invensys, Chennai on system architecture and troubleshooting.
Received training at Balco Learning Center on AB PLC and industrial troubleshooting.
Received training at Balco Learning Center on “ Analysis of hydraulic circuits and troubleshooting”
Received training at Pune "Honeywell dcs in GUS/UCN"
Received training at Noida for Emerson Ovation dcs,15days certify course ACHIEVEMENTS
Management recognized performance by giving time-to-time performance incentives.
Awarded with cash reward for the modification of HAG,CW discharge valve.(CEO Kitty)
Selected as core team member for star improvement project “Mill reliability & availability”.
Flame system like flame scanner, flame TV improvement & reliability.
ETP system re-commissioning.
Recognized by upper management for made ready to DCS with in time while GE(China) Engg deny for same due to some issues.
Selected for core team member for FAT of Honeywell DCS in China. P ROJECTS UNDERTAKEN AND COMPLETION
EBR system installed for DCS U1,U2 & Common .It will automatically save the online complete backup of all network systems(Servers & client PCs).
Logic modification for furnace flame failure due to malfunctioning of flame scanner.
Two separate NAS(Network attached storage System) integrated each with DCS & PLC Network. It will automatically store all History and logic backup. So all the updated backups available in the network itself.
PLC program & hard wire circuit modification for avoiding barring gear tripping due to Soft starter failure.
HP & LP main valves' drifting issue with existing Chinese system was resolved by integrating HP LP bypass system with existing DEH.After integration the drifting issue eliminated. So, problem of opening of valves were eliminated.
DCS Server obsoleteness was one of the key challenge for every plant. Server replacement along with hardware cost is too high. Procured server from open market and replaced with the old machines
Mill reliability & availability.
Coal feeder improvement & reliability.
SWAS Up gradation.
PERSONAL DETAILS
Date of Birth: 08st AUGUST 1984
Permanent Address: H.NO. 1732 Nav nivesh colony Ganga Nagar,Garha,Jabalpur Madhyapradesh
Languages Known: English, Hindi
Passport No: P6180257, DOE: 02.07.2027
DECLRATION
I declare that all credentials shared above are true in all aspects, and if found misleading or fake, my candidature could be terminated.
Name: Avadhesh Tiwari Date: 23-July- 2020 Place: Nagpur