RESUME
SHANMUGANATHAN R
Mobile No: +974********
E-mail: ************@*****.***
OBJECTIVE
To exhibit proactive involvement and good initiative in the work assigned, to impart my services in areas embanked on me, to serve the organization well and to show consistency in my performance and to work hard continuously to the fulfill satisfaction of my employer. ADDITIONAL CERTIFICATE COURSES
HEAT VENTILATION AIR CONDITIONING DESIGN AND DRAFTING.
PLUMBING, DRAINAGE AND FIREFIGHTING.
AUTO CAD.
WORK EXPERIENCES
NAME OF THE COMPANY: ULTIMATE TRADING AND CONTRACTING IN QATAR. DESIGNATION: MECHANICAL ENGINEER (HVAC, PLUMBING, DRAINAGE, FIREFIGHTING). DURATION: JAN 2018- FEB 2020.
NAME OF THE COMPANY: HVAC ENERSAVE SOLUTION AND CONSULTANT IN CHENNAI. DESIGNATION: HVAC ENGINEER AND DESIGN.
DURATION: JUNE 2015- JAN 2018.
PROJECT UNDERGONE IN ULTIMATE
PROJECT TITLE: DPS SCHOOL IN ALWUKAIR.
WORK HANDLING: HVAC (PACKAGED AIR CONDITIONING SYSTEM, DXSYSTEM), FIREFIGHTING SYSTEM CAPACITY OF PUMP IS 1500GPM, PLUMBING AND DRAINAGE.
PROJECT TITLE: ALMUFTAH WAREHOUSE IN BERKAT AL AWAMER.
WORK HANDLING: FIREFIGHTING SYSTEM WITH CAPACITY OF PUMP IS 2000GPM.
PROJECT TITLE: WOQOD PETROL STATION IN ALTHUMAMA AND MESSAIMEER.
WORK HANDLING: HVAC (VRF SYSTEM AND DX SYSTEM), FIREFIGHTING SYSTEM PUMP CAPACITY- 150GPM.
PROJECT TITLE: ALMEERA.
WORK HANDLING: HVAC (WATER COOLED CHILLER-480TR). DUTIES AND RESPONSIBILITIES:
PREPARATION OF DESIGN BASIS REPORT OF THE PROJECT.
COLLECT COORDINATION DRAWING AND CHECK DESIGN OF PLUMBING, DRAINAGE, HVAC, FIREFIGHTING LOAD CALCULATION, DUCTDESIGN, VENTILATION SYSTEM DESIGN, PUMP HEAD CALCULATION, PIPE SIZING, SELECTION OF MATERIALS AND STANDARDS WITH SPECIFICATIONS.
WORK WITH BY PLANNING SCHEDULES AND ASSIGNING THE SITE ACTIVITIES BY EVERY DAY.
AND ATTENT EVERY REVIEW AND CONSULTANT METTING.
PREPARATION AND MODIFICATION OF BOQ, SHOP DRAWINGS, ASBUILT DRAWINGS.
INCLUDE SUPERVISION OF SITE, EXECUTION, COORDINATION, PREPARATION OF SUBMITTAL FOR THE PROJECT.
RAISING FOR RFI (REQUEST FOR INSPECTION) FOR WITNESS/HOLD POINTS.
COORDINATE WITH OTHER SUBCONTRACTORS AND TAKING CLEARANCE REQUIRED FROM THEM TO MAINTAIN WORK FLOW.
COMPLETE THE INSTALLATION ACTIVITIES AND COMISSIONING THE SYSTEM.
AT SITE INSPECTION TIME, FOLLOWING SAFETY RULES AND REGULATION AT DIFFERENT HAZARD AREAS.
PROJECTS UNDERGONE IN HVAC ENERSAVE SOLUTION:
CANARA BANK IN CHENNAI-60 TR DX SYSTEM.
VISHRANTHI HOMES LAST LEAF (RESIDENTIAL) IN CHENNAI- 200HP VRF SYSTEM.
JOUVE FLATIRONS (IT PARK) IN CHENNAI- 60HP VRF SYSTEM & 140 TR DX SYSTEMS.
KAY RESORT (RESIDENTIAL) IN PONDICHERRY – 300HP VRF SYSTEM.
ANNAPOORNA HOTEL IN COIMBATORE – 160HP VRF SYSTEM.
AK AHMED TEXTILES IN MADURAI – 500TR AIR COOLED CHILLER SYSTEMS.
SYDNEY APPARELS (INDUSTRIES) IN JORDAN – 435TR AIR COLLED CHILLER SYSTEMS.
MEGHNA DENIMS (INDUSTRIES) IN BANGLADESH – 200HP VRF SYSTEM & 35TR AIR COOLED CHILLER SYSTEMS.
ITC HOTEL IN ANDAMAN -50TR DX SYSTEM
NANDU LUNGIES IN CHENNAI – EVAPORATIVE COOLING SYSTEM
KWUNG TONG APPARELS LTD IN BANGLADESH-500TR WATER COOLED CHILLER SYSTEMS.
MOHAN METHA (RESIDENTIAL) IN CHENNAI-216HP VRF SYSTEM.
MARTHOMA CHRUCH IN CHENNAI-60TR DX SYSTEMS.
BROADWAY COMMERCIAL (IMAX) IN COIMBATORE –750TR HYBRID COOLING SYSYTEMS
(500TR AIRCOOLED +250TR WATER COOLED CHILLER).
AGS CINEMAS ALAPAKKAM CHENNAI-220TR DX SYSTEM.
EDUCATION
Degree Institute Board /
University
Year of
passing
% marks /
CGPA
B.E.
MECHANICAL
ENGINEERING
Dhanalakshmi College
of Engineering,
Chennai
Anna University,
Chennai
2015 7.1(CGPA)
HSC Alagappa
Matriculation Higher
Secondary School
State Board 2011 82.16%
SSLC Alagappa
Matriculation Higher
Secondary School
Matriculation 2009 78.8%
PERSONAL DETAILS
Name : SHANMUGANATHAN R
Date of Birth : 15.05.1994
Gender : Male
Father’s Name : Ramalingam R
Linguistic proficiency : Tamil, English, Hindi.
Hobbies : Like to play cricket, and football.
Strengths : Team work and Self Confidence
DECLARTION
I hereby declare that the above given information is true to the best of my knowledge and belief.
Place: SIGNATURE
Date: (R. SHANMUGANATHAN)