Post Job Free
Sign in

Technician Mechanical

Location:
Caledon, ON, L7E 3T4, Canada
Posted:
June 08, 2020

Contact this candidate

Resume:

Alan D. Bergey, B.Sc.

** ****** *** ****, ******, On. L7E 3T4

Cell: 647-***-**** E mail: addoto@r.postjobfree.com

electronics Technician Mechanical Technician

Methodical and project-oriented optical / electronics / Mechanical Technician who thrives under pressure in a fast-paced environment of ongoing change

Sets and maintains high standards; conscientious, industrious, energetic, confident

Articulate, breaks technology barrier down, establishes high level of trust, builds synergy between cross-functional personnel to achieve goals and objectives

Keeps on leading edge, well versed in utilizing state of the art technology to deliver quality work

Core expertise includes:

Optical Electronics

Lens & Imaging, Detectors, Lasers, LED, Displays, Automation System, LabView, Mil Specs

Electronics

Electronic Technician Diploma. Telecommunications Technicians Diploma. PLC Diploma

Mechanical

Machine Shop 1 – 6, Milling m/c experience, AutoCAD, Google Sketchup 3D

PROFESSIONAL EXPERIENCE

Quality Assurance Engineer / R & D LED lighting

Valuelight May 2013 – June 2015

Valuelight produces fluorescent and LED energy efficient lights for commercial and outdoor use.

This is a many hats position involving: Quality control. RMA’s

Development testing and safety qualification of new lighting LED units.. UL / CSA / Design Lights Consortium.

Design modification of "off shelf" units ( Mechanical using AutoCAD, Optical modification and electronic drivers.)

Customer liaison and problem solving. Use of Lighting software for determination lighting requirements

OPTO-MECHANICAL TEST TECHNICIAN

Xiris Automation Corp. 2009 – 2010

Optical set-up and testing for machine vision applications utilising high speed digital cameras. R & D for applications in label inspection, label positioning ( Bottles), defect detection ( Optical disks, Solar panels), Pre and post tube welding inspection (Laser line system). Designed and produced many mounts. Gained considerable experience on a milling machine.

OPTICAL TEST & DESIGN TECHNICIAN

Northrop Grumman, Toronto, ON 2001 – 2004

Produced a prototype LED backlight array with even Intensity and Chromaticity. Each colour LED having a different voltage and current drive versus Luminance

Renewed outdated LED display. Duplicated Chromaticity and Luminance output of old LED displays to meet Mil Specs

Actively involved in F18 display pre-production testing automation, wrote procedures, oversaw ‘first off’ testing, provided initial QA for processing specs prior to full production.

Tested new backlights and displays with AR and ITO coatings, with an emphasis on reflectivity verses viewing angle

Alan D. Bergey, B.Sc. PAGE 2

OPTO-MECHANICAL DESIGN TECHNICIAN

Efos Inc., Mississauga, ON 1991 – 2000

Designed optics for Ultracure and Novacure. Increased output through 5mm diameter light guide on previous 100SS system from 2 Wcm-2 to 11.5 Wcm-2

Reverse engineered 100W Hg lamp, improved focusing output through 5mm diameter light guide. Potted new mercury ARC lamps into used Osram reflectors, elevating the average lamp output and lengthening the life producing the following impressive results:

Average Output

Standard Deviation

Hours to 50% decrease in output

Previous Lamp

11.5 Wcm-2

1.0 Wcm-2

200 hours

New Lamp

13.3 Wcm-2

0.15 Wcm-2

600 hours

Conducted research into potential reflective coating with the following findings:

Reflectivity Specification

Notes

Previous Lamp

85% @ 365nm

Estimated to be > 30% @ 250nm

New Lamp

93% average 250 – 390 nm

Minimum 85% @ 250 nm

Designed feedback system for Novacure keeping intensity within –10% of required setting recognised as a competitive figure. Designed beam splitter and detector, which gave an accurate reading of light output controlled by a movable iris

Developed and tested phototherapy light sources including quartz halogen lamps, 1200 watts, 150 watts with delivery down large light guides for external body use. For the treatment of various internal cancers Xenon lamps were the light source with small diameter fibres

Conceived various radiometers, calibrated scanning radiometers to NIST standards

Led numerous minor projects from LED arrays to microwave excited light sources.

INSTRUMENTS

Utilized the following optical instruments:

Oscilloscopes

Multimeters

Wave Generators

Interferometers

Lock-in-Amplifiers

Spectrum Analyzers

Polar scopes

Lasers

Fiber Optics

Photo-detectors

Scanning Radiometers

Refract meters

EDUCATION

PLC Technicians Diploma. (George Brown College). 2015

Electronics Technician s Diploma. (ICS Canada) 2007

Electronics Telecommunications Technicians Diploma. (ICS Canada) 2008

Machine shop 1-6 ( Sheridan College. ) 1994

Open University

B.A. Majoring in Biochemistry & Photochemistry. 1990

Northumbria University, Newcastle, U.K. 1986

Post Graduate Diploma in Opto-Electronics

Nottingham Trent University, Nottingham, U.K. 1985

BACHELOR OF SCIENCE – Combined studies in sciences ( Physics & Chemistry)



Contact this candidate