Post Job Free

Resume

Sign in

Electrical testing and commissioning engineer

Location:
Coimbatore, Tamil Nadu, India
Salary:
40k-60k
Posted:
June 05, 2020

Contact this candidate

Resume:

BOOPATHY.E

Mobile: +973-******** (Bahrain), +919********* (India) Email: addmcb@r.postjobfree.com

EXPERIENCE ERECTION, TESTING AND COMMISSIONING ENGINEER PGP Contracting, Bahrain 27/01/2018 - 13/02/2020 Erection, Testing, commissioning and maintenance Power Transformers of Up to 500MVA/295MVA substation Distribution

Tan Delta, Insulation Resistance, Magnetic current test, short circuit test, Turn and Voltage Ratio test, Magnetic balance Test, Vector group test, SFRA, Recovery Voltage Measurement, Floating Neutral, & BDV to be carried out during project.

Installation of Power Transformers and Reactors.

Overhauling of Power Transformers and Repaired/replaced equipment to ensure proper functioning.

Transformer Oil Filtration, Vacuum Process, Oil Sampling,Dew point Test & Passivation should be done if the BDV Value of the oil comes down from the certain limit.

Checking the operation condition of Buchholz Relay, OLTC, PRV,GDR, Winding & Oil Temperature Indicator Calibration, WTI Secondary Injection Calibration, Cooling Fans and Pumps by operating manually for both Alarm and Tripping circuits.

Project Schedule and Before Planning Material And Man Power Arrangement of Project.

To Prepare and Summit the Testing and Erection Report to client. 15/01/2014 - 05/01/2018 TESTING AND COMMISSIONING ENGINEER VOLTECH ENGINEERS PVT LTD, Chennai, India

Testing, Commissioning and maintenance of 800kV HVDC Indoor/Outdoor substation and substation equipment’s.

Testing, Commissioning and maintenance of 415V to 400kV HVAC Indoor/ Outdoor substation and substation equipment’s.

Testing & Commissioning of Static and Numerical Protection Relays of various types of leading makes.

Trouble shooting of electrical circuits, control and protection circuits at different type of process plants and power plants.

Commissioning of Generators up to 1500KVA.

Testing of Generators, CT, PT, CVT, Breakers, LA, Capacitor Bank, Resistor Bank, Isolators, UG cables, Power Transformer, Generator transformer, Motors.

Knowledge of all Differential Protection such as Generators, Power Transformer, Generator Transformer, motor, Cable, Bus bar, Line and REF Protection .Teed diff protection.

Inspection of control and relay panel, preparation of Test Report, cable schedule & termination schedules for sub-station, power plant, and process plant.

Testing and commissioning of control & relay panel for Transformer, Bus Coupler, Bus-Transfer, and Line feeder.

Testing of Protective Relays for various needs. Experience with over current and earth fault relays.

Develop and review equipment specifications for voltage regulators, capacitors, batteries and chargers.

Co-ordination with client in As Built Scheme drawing submission, test report And Erection Report submission.

Project Schedule and Before Planning Material And Man Power Arrangement of Project. EDUCATION

Tagore Engineering College, Chennai, ANNA UNIVERSITY Bachelor Of Electrical and Electronics Engineering

Adhiparasakthi Polytechnic College, Melmaruvathur, Tamil Nadu Diploma in Electrical and Electronics Engineering SKILLS

Experience in reviewing designs to assure compliance with engineering design, applicable codes, constructability, and industry standards

Ability to work in and foster a strong team environment with minimal supervision

Good working knowledge of the procurement process

Knowledgeable of the design, construction, or operation of an electric generating plant

Knowledgeable of the design, construction, or operation of natural gas compressor station equipment

Good performance management skills

Knowledge of industry codes and standards as they relate to design and construction Provirus

Strong communication skills (verbal/written/listening/presentation)

Problem solving skills with ability to analyze and recommend solutions on problem

I have done Electrical AutoCAD Course.

WORK PROFICIENCY:

Erection, Testing & Commissioning of Electrical equipments like CT, PT, CVT, Circuit breaker, LT & HT Motors.

Testing and Commissioning of Control & Relay panel for Generator, Transformer, Bus Coupler.

Testing and Commissioning of NGR, NGT for Transformers & Generators.

Trouble shooting & Maintenance of Battery Charger.

Supervision of Cable laying as per cable schedule.

Commissioning of Protections like Generator Protection, Transformer Protection, Differential Protection, REF Protection, Bus bar Protection, Motor Protection and Synchronizing Scheme.

Trouble shooting of all Electrical Equipments, Power, Control & Protection Circuits. Maintenance of Construction Power & Plant Startup Power.

Maintenance of Diesel Generators.

Scheme modifications as per the field Requirement and As Built Scheme drawing Submission.

Preparing Control, DCS Cable Schedules and make as built if any.

Handling the duties with safety.

CURRENT PROJECT: Bahrain

400 KV, 150 MVAR, HVAC Rectors, Ras legrain -HYUNDAI ELECTRIC LTD. PROJECTS EXECUTED :

PGP CONTRACTING Bahrain

Erection, Testing & Commissioning and Overall scheme checking of 220KV HVAC / 130 MVA Transformer (4 no’s) And 220 KV /30MVA Transformer with 21KV/30 MVA Reactor for EWA at BMP Refinery through HYUNDAI ELECTRIC LTD.

Erection, Testing & Commissioning and Overall scheme checking of 220KV HVAC / 150 MVA Transformer (3 no’s) And 66KV /20MVA Transformer with 21KV/30 MVA Reactor for EWA at East Sitra through HYUNDAI ELECTRIC LTD.

Rectifier Repairing Work, Testing & Commissioning and Overall scheme checking of 232 KV HVAC / 40 MVA Transformer

(4 no’s) for ALBA through FUJI ELECTRIC LTD

Erection, Testing & Commissioning and Overall scheme checking of 232 KV HVAC / 100 MVA Generation Transformer

(4 no’s) for EWA at Riffa through HYUNDAI ELECTRIC LTD.

Rectifier Replacement, Testing & Commissioning and Overall scheme checking of 11.5 KV/1.2 KV HVAC / 40 MVA Rectiformer (2 no’s) for ALBA through ABB LTD.

Erection, Testing & Commissioning and Overall scheme checking of 220KV HVAC / 150 MVA Transformer (4 no’s) And 66 KV/20MVA Transformer with 21KV/30 MVA Reactor for EWA at Safra through HYUNDAI ELECTRIC LTD.

Erection, Testing & Commissioning and Overall scheme checking of 220KV/132KV HVAC / 315 MVA Transformers (2 no’s) and 220KV/ 33KV HVAC /120MVA Transformers (1no’s), 220KV/11KV HVAC/60M Transformers (2 no’s) with 220KV/450 MVAR Reactors for ALBA through SIEMENS W.L.L. VOLTECH ENGINEER’S PVT LTD India

Testing & Commissioning and Overall scheme checking of +800HVDC / 400 KV, GIS Switchgear with 125 MVA Reactor for Power grid at Kurukchetra in Haryana through GE T&D LTD.

Testing & Commissioning and Overall scheme checking of +800HVDC / 400 KV, Switchyard with 240 MVA Reactor – 2 no’s for Power grid at Alipurduar in West Bengal through ABB.

Testing & Commissioning and Overall scheme checking of +800HVDC / 400 KV, Switchyard with 240 MVA Reactor – 2 no’s for Power grid at Biswanathchriali in Assam through ABB. PERSONAL PROFILE:

Father’s name : Mr.Ettiyappan .B

Date of birth : 27/05/1989

Marital Status : Single

Languages Known : Tamil, English, and Hindi(speaking only) DECLARATION

I hereby declare that all the details furnished above are true to the best of my knowledge. Yours Sincerely

Date:

Place: CHENNAI Boopathy.E



Contact this candidate