Post Job Free

Resume

Sign in

Power Plant Thermal

Location:
Raipur, Chhattisgarh, India
Posted:
June 29, 2020

Contact this candidate

Resume:

RESUME

Guneshwar Singh E mail : add6t0@r.postjobfree.com L & T – Sargent & Lundy Limited Mob. No : 798-***-****, 989-***-****

Career Objective:

I want to be work with committed & dedicated people to continual improvement of the world, which will help me to explore myself fully and realize my potential willing to work as a key player in challenging & creative environment. I desire to work in stimulating team environments that promotes the interchange of ideas, knowledge and experience.

Professional Synopsis :

A dynamic professional BE Mechanical & Certified Energy Manager with fifteen years experience in plant performance monitoring & efficiency improvement, operation, maintenance planning,erection & commissioning of 600 MW coal based Thermal Power Plant.

Worked with M/s L & T– Sargent & Lundy Limited at 2 X600 MW MB Power (MP) Jaithari Anuppur (M.P). & 6X600 MW KSK Mahanadi Power Company Ltd. Nariyara, Akaltara Bilaspur (C.G.)

Worked earlier with M/s Lanco Infratech Ltd. (EPC Thermal Power) 2 X600 MW Moser Baer Power (MP) Ltd., Jaithari, Anuppur (M.P.) & 2 X660 MW Lanco Amarkantak Thermal Power Limited, Korba ( C.G.).

Worked earlier with M/s Jindal Power Limited, 4X600 MW Thermal Power Projects Tamnar, Raigarh (C.G.).

Worked earlier with M/S BHEL (PSWR) 2 X 250 MW NTPC – SAIL Expansion Project Bhilai (C.G.) as Project Engineer.

Worked earlier with M/s Chhattisgarh Electricity Company Ltd. Siltara, Raipur as Turbine desk Engineer.

Worked earlier with M/s Jyoti Structures Ltd. Urla Industrial area Raipur.

BE Mechanical from Govt. Engineering College, Raipur (Now NIT Raipur). Studied Power Plant Engineering (Conventional & Unconventional Energy System) as elective subject.

Certified Energy Manager Behalf of the Bureau of Energy Efficiency, Ministry of Power, Government of India.

Work Experience

From September 2017 to till date :

M/s L & T–Sargent & Lundy Limited at 2X600 MW MB Power (M.P.) Ltd. Jaithari, Anuppur (M.P.) & 6X600 MW KSK Mahanadi Power Company Ltd. Nariyara, Akaltara Bilaspur (C.G.)

Review plant performance parameters PLF,PAF, GCV,heat rate, Aux.Power consumption, specific Coal consumption, Specific steam consumption, specific oil consumption, specific DM water consumption, specific raw water consumption,Unburnt carbon % in fly ash & bottom ash, coal fineness in mill, review condition monitoring parameters, lube oil analysis, plant maintenance data, environment data, fire & safety etc.

Prepare monthly reports and exception report, specifically highlighting of major concern areas related to operational efficiency, safety and sustainability of the plant and providing suggestions wherever necessary.

Monitor regularly operation parameters through regular inspections and review of logs, analyze, identify and take appropriate actions to correct unsatisfactory system and plant conditions to improve plant performance.

Monitoring routine, preventive, breakdown, corrective maintenance, ensures availability of equipment’s to achieve maximum plant efficiency.

Monitoring the Annual Overhauling, ensure the completion of identified defect rectification as per planned schedule.

Review project schedule, Identify gap areas & major missing equipment’s which may impede the commissioning schedule. Ensure the proper implementation of progress work & availability of equipment’s to meet the commissioning schedule for 600 MW Thermal Power Plant.

Monitoring the completion of all the commissioning activity to achieve the milestone for Hydro test of IBR piping, Alkali flushing of TG piping, lube oil flushing, steam blowing for, TG on barring, synchronization for 600 MW Project.

Monitoring the Commissioning of CW system, Cooling Towers, CCCW system,OCCW system, CEP,MD BFP, EH oil system, lube & Jack oil system, Stator cooling water system, HP- LP Bypass system, Gland Sealing system, TG Extraction & drains,TD BFP & their Aux system etc.

Site Coordination for review of 2X660 MW Lanco Amarkantak project korba for cost to completion, review balance work, material condition, stock varification, store audit, schedule for completion of balance work.

From January 2016 to September 2017

M/s Lanco Infratech Ltd.,2X600 MW MB Power Project, Jaithari, Anuppur(M.P.) & 2 X660 MW Lanco Amarkantak Thermal Power Limited, Korba(C.G.).

Pre commissioning activity, preparation of pending points & follow up for completion of work for commissioning to achieve the commissioning schedule of AHP,CHP,HVAC & FDPS system for 2X660 MW Thermal Power Plant.

Commissioning of bottom ash handling & ash disposal system, clinker grinder, jet pumps, air oil converter, feed gate & over flow tank pumps, Ash slurry pumps, water pumps, seal water pumps, makeup water pump, and eco water pumps.

Commissioning of fly ash conveying system, fluidizing blowers for ESP hopper and fly ash silo.wet & dry ash system, conditioner water pump, seal water pump, dewatering system, hydrobin, settling and surge tank, sludge transfer pumps, sump pumps.

Commissioning of Coal handling system Puddle feeder, Apron feeder, belt conveyor drive systems, Flap gates, Travelling Tripper, Coal feeders, DE & DS system for 2X600 MW Coal handling system.

From May 2009 to January 2016

M/s Jindal Power Limited, 4 X600MW Thermal Power Project Tamnar, Raigarh (C.G.), (From May 2009 to June 2015), (July 2015 to Jan.2016 JSPL Angul).

To ensure the reliable operation of the unit by managing field operation & maintenance of BOP systems CWACW system, Misc. Pumps, service water, firewater, portable water, CT makeup, sump pumps etc.

To ensure the availability of major standby equipment with proper change over & periodic maintenance.

To monitor the systems & operational parameters of the equipment’s CWACW pumps, VAMs, chillers, AHU, Air Washers, cooling towers, pumps, fire water pumps, service water pumps, portable water pumps, CT make up pumps, cranes & hoists.

Responsible for PTW for maintenance of equipment’s through proper isolation as per SOPs and proper lock out/tag out for safety of equipment’s & people during shutdown work.

Planning & monitoring the shutdown work, ensure adequate availability of T&P and manpower to complete the work as per schedule mentioned in PTW.

To execute the Erection & Commissioning work according to the drawings, quality standards and with commissioning & safety procedures for 4X600 MW Thermal Power Plant.

Coordination with contract & purchase department for procurement of urgent material & deployment of contractor for Erection work, make NFA, take budget, and create PR (material & service). Follow up availability of materials & deployment of contractor.

Working knowledge in SAP (MM & PS module) make SES for Erection bill,Z-bill,PR,Material reservations, Gate Pass etc.Review Billing documents (Supply & Erection)as per PO.

From Oct. 2007 to April 2009

BHEL (PSWR) 2 X 250 MW NTPC –SAIL Power Company Limited Expansion Project, Bhilai (C. G.).

Pre- commissioning, Commissioning activity of TG. Aux. System BFP, CEP, DMCW pumps, CW System, ACW booster pump, vacuum pumps, Condenser, De-aerator. Aux. Steam system, gland steam system, lube oil cooler, AOP, JOP, and control valves, generator seal oil skid, HPLP bypass valves.

Oil flushing & Hydro test of lube oil & jack oil system. Hydro test, chemical cleaning & steam blowing for TG & Aux. piping. All start up test of TG Aux. equipment’s from TG rolling to full load operation of Turbine. Make punch point/ check list & rectify problems to achieve full load operation& COD of unit.

Co-Ordination with contractors & sub contractors for timely completion of erection work as per commissioning schedule. Ensure all the equipment’s are erected as per P& I D diagram.

Operation of CW ACW system, DMCW system, BFP, AOP, JOP, CEP. Steam charging main steam line, HRH, CRH, Aux Headers, Gland sealing, HPLP bypass, De-aerator pegging. Steam dumping.

Co-ordination with boiler inspector office govt. of Chhattisgarh for boiler registration & other IBR related work.

From May 2005 to July 2007

Chhattisgarh Electricity Company Limited Siltara, Raipur (C.G)

Overall responsible for shift operation of Turbine & TG Aux. System, trouble shooting of turbine, Turbine rolling from control room DCS & field maintenance of 2X30 MW Thermal Power Plant.

Responsible for log sheet preparation & maintain various performance data for all equipment. (Turbine, CW Pumps, Cooling Tower Fans, CEPS, BFPS, MOPS, Oil Coolers, and Condenser etc.)

Responsible to carry out the preventive maintenance, overhauling & commissioning, annual shut-down of TG & Aux. System. Ensure proper implementation of PTW during Operation of equipments.

Operation of AFBC Boiler 2X90 TPH. Co-ordination with interdepartmental to run the plant smooth operation.

Feb. 2005 to May 2005

Jyoti Structures Limited. Urla Industrial Area, Raipur (C.G)

Production Planning & Fabrication of structures (transmission line towers & communication towers Projects).

Co-ordination with various Dept. (Steel, fabrication, QC, maintenance, galvanizing, dispatch) for timely completion of parts of towers.

Optimum utilization of Manpower & Machine to enhance production as per job-card.

Ensure implementation of safety & 5S at work place.

Technical Qualification:

B.E.Mechanical from Govt.Engg.College, Raipur (Now NIT Raipur) with first div. (65.4% Agg.), Year 1997–2001.

Academic Qualification:

Higher Secondary Examination from M.P.Board, Bhopal with first div. (72.6%).

High School Examination from M.P.Board, Bhopal with first div. (75.6%).

Personal Skills :

Honest, sincere and a dedicated worker with a high level of Integrity.

Flexibility to work hard for long hours and positive attitude towards work until the goal I accomplish.

Personal Information:

Name : Guneshwar Singh

Father’s name : Sh.Meghnath Patel

Date of birth : 24 September 1977

Address : Village–Mohandi, Post–Nardha Dist - Durg (C.G.), 490024

Marital Status : Married

Language known : Hindi, English

Present CTC : 13.96 Lacks PA

Expected CTC : Negotiable

Declaration:

I hereby declared that all the information above given by me is true to the best of my knowledge.

(Guneshwar Singh) Place: Korba (C.G.)



Contact this candidate