Post Job Free

Resume

Sign in

Electrical Engineering

Location:
Jamui, Bihar, India
Posted:
February 24, 2020

Contact this candidate

Resume:

CURRICULUM VITAE

MOHAMMAD MODASSAR MALLICK

(: +917*********

Email: adbysd@r.postjobfree.com

Skype Id: mohammad.modassar78

Position Applied: ELECTRICAL & INSTRUMENT QA/QC INSPECTOR CUM SUPERVISOR

Current Location: INDIA

OBJECTIVES:

To apply. Share my knowledge and skills that I had learned from my past experience and express my ability and performance of maintaining good standard quality. Workmanship with my peers of different nationalities

ACADEMIC QUALIFICATION

SSC Passed from J.H.S. Jamui (Bihar) in 1995 with first division

TECHNICAL QUALIFICATION

Diploma in Instrumentation Engineering in 1998

SAFETY CERTIFICATION & TRAINING:

BOSIET -Basic offshore safety Training, Quality safety training, HSE Training,H2S,Confined Space entry, work at height, Excavation, Heat Stress,Level2 - O2 Practice.

COMPUTER SKILLS: -

Microsoft Word, Microsoft Excel, Internet, Emailing, Surfing and browsing, ETC.

CAREER OBJECTIVE:

As Electrical & instrumentation Inspector and supervisor, having very good experience in project engineering construction, Shutdown and maintenance work in oil and gas, refinery, petrochemical and steel industry in various role of the process control system.

Ensure the implementation of quality management system and compliance to ISO 9001:2000, applicable codes, standard and specification

Attended pre-inspection meeting, installation, inspection, maintenance, test repair and selection of the materials equipment and facilities, using the standards which can comply with latest addition.

Understand various engineering procedure engineering standards material system specification forms and data sheet, test procedure industrial codes and standards related to instrumentation and electrical projects like, NEC (NFPA-70), IEC, ISA, ISO, IEEE, NEMA, API, ANSI, SAES

Intrinsically safe (IS) & Foundation field bus system,

Inspection for the installation of CCTV Camera & speaker in the electrical substation & control building, also witness the electrical HV & MV Cable splicing as per the approved specification.

Experience in reading P&ID, instrument loop diagram (ILD), functional logic diagrams (FLD), instrument hook–up diagrams schematics and electrical Drawing.

Consult and coordinate with client personnel to ensure work execution in safe and accordance with their requirement using best standards.

Handling of manpower and equipment in proper and execute on the spot solution by using common sense when trouble shooting and decision making.

TOTAL EXPERIENCE: 16 YEARS

EMPLOYMENT HISTORY /DUTIES RESPONSIBILITIES:

Company : DOME DZ INTERNATIONAL GENERAL CONT

Position : E & I QA/QC inspector

Project : AL- TAWEELAH ALUMINA Refinery Project (Abu Dhabi)

Period : 17 Sept - 2017 to 12 Sept 2019

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like all Control panel, DCS Panel, consoles, FGS Panel and Junction Box Performed the Installation inspection of primary & secondary instrument cables, Fiber Optic Cable, cable dressing, Glanding & Termination at instrument, JB & Control Cabinet side, Performed the installation inspection of field Conduit, tray, Distribution board, Motor, Lighting Fixture, Electrical & instrument Panel, Control & Power cable laying, Glanding & termination, UPS battery installation, UPS Battery terminal and Bus bar Torquing, main bus bar IR & Continuity test in MCC, Main bus bar contact resistance measurement, Installation of transformer, Motor, switchgear module & distribution board, winding insulation resistance test, Cable joint kit, Inspection for the Installation of Field mounted Transmitter, Pressure gauge, ON/OFF Valve, SOV & Control Valve, Junction Boxes, Tray and Local Panels, Pneumatic Leak Test of Air Line Tubing /Impulse line tubing & tubing accessories, IR and Continuity Check for Instrument Cables.

Company : DOME DZ INTERNATIONAL GENERAL CONT

Position : E & I QA/QC inspector

Project : Flare modification ASAB FFD Project (Abu Dhabi)

Period : 16 Oct – 2016 to 13 Sept - 2017

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like all material receiving, cable drum, Conduit, tray, JB, Panel box, DB box, Transmitter, Pressure gauge, tubing & tubing accessories, Cable joint join kit, motor, switchgear, Inspection for the Installation of Field mounted Instruments, Junction Boxes, and Local Panels, Pneumatic Leak Test of Air Line Tubing /Impulse line tubing, Insulation Resistance test and Continuity Check for Electrical & Instrument Cables.

Company : KENTECH QATAR

Position : Instrument QA/QC Inspector

Project : QATAR SHEEL GTL MTA2 (SHUTDOWN)

Period : 15 Dec 2015 to 30 April 2016

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like positioner isolated from JB OR MDF & confirmed disconnecting signal wires from instrument diagram matched with instrument loop diagram, trifoliate label are installed, instrument stanchion installed, as per drawing, cable terminated as cable wiring connection drawing, unused cable entries are plugged, JB body earthing connection & stopper lug are inplac, positioner power is isolated by disconnection, instrument loop diagram and having wire markers as per found connection wire marked with correct polarity to as found condition stroke test no air leak, stroke check satisfactory wire gland properly preserved, after disconnected, new positioner installed, shall be put the calibration sticker in place, tubing accessories properly reinstalled to as found hookup and and are not damage, tubing connection confirm no leak used for snoop, valve stroke test raising & falling, control valve with solenoid trip tested,solenoid valve tested & not leaking, clean valve externally and megring & continuity testing for electrical cable, HV, MV, LV, testing of switch gear and connection of motor, switch gear, MOV, testing of electrical lighting, Tray, cad weld earthting and DB,ETC.

Company : BUREAU VERITAS (ABUDHABI)

Position : E & I QA/QC Inspector

Project : GIP PLATFORM, ADMA (OFFSHORE)

Period : 5 May 2015 to 3 Nov 2015

DUTIES AND RESPONSIBILITTIES:

Duties involve inspection like quality assured with a team of loop checkers through monitoring at the control room HONEYWELL System, prepares Turn-over–Package documents for mechanical completion that consist of all engineering and construction disciplines like As-Built Drawing, test report, Punch List, Vendor drawing and other P.O.R related documents etc, supervised the job installation of Junction boxes, frames and Cable trays work, also witness the Electrical LV & MV cable and Fiber Optic cable splicing as per the approved drawing and Specification, functional testing of all instrument and loops including Fire & Gas and telecom (PA/GA), electronics analog and digital signals & emergency shutdown (ESD) system. Check telecom cable continuity test, cable tray installation & cable laying. Alarm and fire suppression system, FOC cable, OTDR test shall be carried outer splicing of FOC cable, installation of CCTV camera, Telephone.

Company : KENTECH QATAR

Position : Instrument QA/QC Inspector

Project : QATAR SHEEL GTL MTA,1 (Shutdown)

Period : 21 Jan 2015 to 9 April 2015

DUTIES AND RESPONSIBILITTIES:

Duties involved inspection like transmitter, RTD/TC, Positioner, SOV, power is isolated and disconnecting wire from JB or MDF, Confirm connection with instrument loop drawing, main air supply to valve is isolated from manifold or isolation valve, positioner removal, position and orientation valve feedback on positioner,wire,tubing accessories positioner shall be re installed, valve calibrated & stroke test by raising &falling command to confirm, instrument air vessel shall be inspected and tested valve workshop as found leak test shall be executed overhauled detailed, ETC.

Company : SAIPEM AGIP KCO (KAZAKHSTAN)

Position : E & I Supervisor

Project : ISLAND HOOK UP PROJECT (OFFSHORE)

Period : 8 April 2013 to 19 Oct 2013

DUTIES AND RESPONSIBILITIES:

Duties involve in electrical & instrumentation construction activity, high voltage and low voltage cable connection, DB installation, MOV installation, electrical tray installation, electrical cable laying, panel installation, motor installation, Supervised, inspected and instrument cable duct bank, cable pulling, from plant control room to field JB and RGS conduit stanchion of instrument devices, marshalling panel, junction boxes installation, Mounting of instrument devices such as (Pressure level, flow and temperature) transmitters RTD and thermocouple switches and control valves, calibration of transmitter control valves, switches of all parameters like pressure, level temperature and flow.

Company : DOME DZ INTERNATIONAL GENERAL CO (PETROFAC )

Position : Instrument QA/QC inspector

Project : Asab phase FFD Project (Abu Dhabi)

Period : 5 Feb -2012 to 24 Nov 2012

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like for the Installation of CCTV camera & Speakers in the Electrical Substation Sighs and Main Control Building, also witness the Electrical HV & MV cable and Fiber Optic cable Splicing as per the approved drawing and Specification, routine area Surveillance of Instrumentation erection activities, Inspection & Witnessing according to Project Specification and QCP & ITP, Established field inspection & Testing Procedures for E & I works with the assistance of Site Project Engineers, Inspection for the Installation of Field mounted Instruments, Junction Boxes, and Local Panels, Pneumatic Leak Test of Air Line Tubing /Impulse line tubing, Insulation Resistance test and Continuity Check for Electrical &Instrument Cables. Inspection for the Installation of DCS Panel, ESD Panel, Fire & Gas System Panel, Consoles & Computers with Printer, Communication system panel and Weather Monitoring System in the Main Control Building, Prepares Turn-over –Package documents for mechanical completion that consist of engineering and construction disciplines like As-Built Drawing, test Reports, Punch List, Vendor drawing and other P.O.R related documents etc. also witness the Electrical HV & MV cable and Fiber Optic cable Splicing as per the approved drawing and Specification.

Company : Dayemyung Eng & Const. Co. LTD

Position : Instrument QA/QC inspector

Project : Ras Girtas Power Co Rapo (Qatar)

Period : 8 April -2010 to 13 Sept-2011

DUTIES AND RESPONSIBILITIES;

Duties involve inspection like of Lighting circuit, Check the Junction box name plate, switch inside the lighting fixture, tightness of all wiring & earthing connections, light fixtures, LV Distribution board, LV Switchgear, tightness of all bus bar joints, bus bar support insulators, transformer Winding testing, earth continuity (Neutral to earth & Body to earth, primary & secondary insulation resistance, power cable termination primary & secondary side tighten, panel cooling fan,filter condition, Heater Insulation resistance, all instrument and loops including Fire & Gas and telecom (PA/GA), electronics analog and digital signals & emergency shutdown (ESD) system, Duties involve inspection like Co-coordinating with Consultant and Clients for the final acceptance of the plant hand over, assists in the Preparation, Review and Updating of Company’s Quality Control manual and operating procedures in accordance with the ISO 9000 Quality Control System.

Company : C.C.C (Saudi)

Position : Instrument QA/QC Inspector

Project : KHURSANIYAH GAS PLANT PROJECT

Period : 2 July - 2007 to 12 June – 2009

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like familiar with International standards NACE, ASTM, BSI, IEC, ANSI, API, also familiar with latest Calibration Certificates, all test measuring instruments are in operational calibrated condition which will be utilized, also responsible for Checking, verifying Reviewing the Construction drawings Covering Specification AFC, IFC, P&ID, ILD and other attachments prior to installation, also familiar with latest Calibration Certificates, all test and measuring instruments are in operational calibrated condition which will be utilized, also responsible for Checking, verifying & Reviewing Construction drawings Covering Specification AFC, IFC, P&ID, ILD and other attachments prior to installation, check telecom cable continuity test, cable tray installation & cable laying. Alarm and fire suppression system, FOC cable, OTDR test shall be carried outer splicing of FOC cable, installation of CCTV Camera, Telephone.

Company : CCC Abudhabi

Position : Instrument QA/QC Inspector

Project : GASCO PROJECT ABUDHABI

Period : 02 Nov- 2005 to15 Feb-2007

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like coordinate various trades and their respective scopes of work, Supervised the Job of coordination with QA/QC related to all documentation work, each and every loop package finalize review through myself, I was handling one, who is keeping all the record and the entire report sheet, inspection like Instrument installation and witness for field & lab instrument Calibration, Like control valve, on off valve, flow, pressure, level, temperature, RTD Thermocouple, level troll & Interface level troll, and Switches. Knowledge in MCT (Multicore Cable Transmission), Check the electronic and pneumatic instrument as transmitters P.SH, P.S.L, I/P converters, Positioner, control valves, controllers solenoid valves, on/off valve also responsibility for all type of Instrument activities.

Company : Galfar Engineering & Const

Position : Instrument QA/QC Inspector

Project : SOHAR REFINERY Muscat (Oman)

Period : 10 Dec 2003 TO 06 May 2005

DUTIES AND RESPONSIBILITIES:

Duties involve inspection like Inspection for the Instrument Cable Trenches prior to cable Pulling and after Cable Pulling to release for the next activities. also inspection of Cable ladders tray and Cable trays in the Field, Panel installation in control room, material to be check against as per material schedule to ensure correct specification, SIH and in the Main Control Buildings, functional testing of all instrument and loops including Fire & Gas and telecom (PA/GA), electronics analog and digital signals & emergency shutdown (ESD) system. Check telecom cable continuity test, cable tray installation & cable laying, alarm and fire suppression system, FOC cable, OTDR test shall be carried outer splicing of FOC cable.

Company : S.A KENT (K.S.A)

Project : Rastanura Refinery (Saudi Arabia)

Position : Instrument Supervisor

Period : 4 Oct-2001 to3 Nov-2003

DUTIES AND RESPONSIBILITIES:

Construction activities via installation and calibration monitoring the worked performed by the construction group confirms to the approved construction drawing as per project specification and standards, Familiar with latest calibration certificate, all test & measuring instrument are in operational & calibration, condition which will be utilized in functional checks, Calibration loop checking, pre-commissioning & commissioning works, also training of personnel & guiding subcontractors, Responsible for checking verifying, reviewing the construction drawing covering specification data-sheet, IFC,ILD,IFC, P&ID and others attachment prior to installation and during inspection, execution of installation inspection and test plan for each phase of instrumentation activities, arranging inspection with client for final acceptance, effectively coordination with other related discipline performed installation inspection, testing and commissioning job for the following field instrument installation cable meggering & continuity check, instrument component installation inspection and final commissioning of inst. DCS system, loop check, from field instrument to main console monitoring system.

Company : Nagarjuna

Position : Instrument Technician

Project : Fertilizer Ltd. (Kanpur)

Period : 14 Sep-1998 to28 July-2001

DUTIES AND RESPONSIBILITIES:

Working as group leader for loop testing, functional test, cable laying, glanding, loop checking, and commissioning and pre commissioning,Calibration of FT,LT,TT, PT,F&G detector system, control valve, ESDV, MOV, SOV,ON-OFF VALVE, switches (PS,TS,FS,

& LS),Installation of instrument, tray work, impulse line, SS tubing, tubing, fabrication and erection of JB.

CONVERSANT WITH:

Instrumentation layout drawings.

Process & instrumentation (P&ID) drawing.

Instrument index

Instrument installation standard details

Loop index of instrument

Instrument loop diagrams.

Electrical & instrument interconnecting drawing etc.

Instrument hook-up drawing

DETAILS:PERSONAL :

Name : MOHAMMAD MODASSAR MALLICK

Father’s Name : MOHAMMAD RAZAUL HODA

Date of Birth : 10-10-1981

Place of Birth : Jamui

Marital Status : married

Languages Known : English, Hindi, & Urdu

Religion : Islam

Nationality : Indian

Permanent Address : Mohd Modassar Mallick

C/O – Mohd Razaul hoda

Post - Lohra -Dist - Jamui

Pin no – 811307

Bihar (India)

PASSPORT DETAILS:

Passport No : M8780319 (ECNR)

Date of Issue : 23.04.2015

Date of Expiry : 22.04.2025

Place of Issue : Patna (India)

PERSONAL PROFILE:

Giant experienced in the field of construction, QA/ QC Inspector and Supervisor department, Pre-commissioning / Commissioning / Testing in various field of industries. Able to read Analog and Digital Logic Diagram, Schematic Diagram, Loop Diagram, P&ID, instrument Location and General Arrangement Diagram, Plane use for start up, testing, commissioning and troubleshooting with the help of some equipment. Acquired the ability to operate DCS console prior to loop checking,

Gained skills in troubleshooting panel view for DCS pertaining to Harmony Network, Block AI, DI and relay Module, Performs calibration of all types of instrument prior to loop checking.

Having Construction Experience as a Supervisor for Tray work, Conduit work, Fabrication, Installation of stands frame & supports, Cable glanding & termination of Power and Control cables.

Supervised the job installation of Junction Boxes, Frames and Cable Trays work,

Preparation of MRIR (Material Request inspection report) little bit information in In tools.

QA/QC INSPECTOR all the quality assurance & quality control visual inspection of instrument quality

All the material gone be a QC Tested QC passed & certify by our quality control department as well, Etc.

Preparation of all ITP’S QCP’S & MSD. Surveillance and NCR through client to sub contractor Construction.

Quality Assured & All RFI’S raised with AFC site Instructions copy by the completion of construction work.

Visual Internal Inspection with Contractor QA/QC Inspector make subroutine and as-built drawing for IFC And then final Inspection by main client ADCO QA/QC Inspector authorize to Reject or approve with comment. and for rectification & modification to Construction.



Contact this candidate