Total * Yr. Experience of Boiler & Turbine DCS Operation & Commissioning.

Presently working in 2*350 MW PF Boiler as a Deputy Manager at India Power Corporation LTD, Nellore.

Worked as an Asst. Manager (Turbine Commissioning & Operation) in 2*660 MW supercritical Boiler at NTPC site Solapur for Alstom Power LTD

Worked as an Operation & Commissioning Engineer in 2*600 MW PF Boiler in Reliance Energy LTD at Raghunathpur site (W.B).

3.5 Year Experience of BTG Operation in 246 MW Boiler at ABhijeet energy PVT LTD, Nagpur. Leading BTG commissioning & Operation activity independently & proficiency in managing commissioning & operation activity from Control room & Local. B.E (Mech.) from G.H.R.C.E Nagpur (MS) Graduated as June-2010. Boiler & turbine DCS & Field operation

Handling emergency situation in plant

Leading operation and Commissioning

of 2*350MW boiler & Turbine

commissioning & operation of 660 MW

supercritical unit of Alstom turbine

Commissioning & operation of 2*

600MW & 2050tph subcritical boiler of

SEC make

Good decision making skills with

positive approach

Operation of 250tph boiler of WUXI

HUANG make

Familiar with Honeywell, Yokogawa,

Alspha & Schneider DCS systems

Process Improvement & optimization

Improvement in APC, HR & Specific

coal/oil consumption

Process analysis

Planning Plant activity

Reduction in DM water consumption.

Deputy manager in Power Plant

+919*********

ada4sk@r.postjobfree.com

NITIN GAWANDE

AGE

33

+917*********

WORK EXPERIENCE

9 Years

ABOUT ME

Highly skilled engineer with 9 years’ experience, working in complex and large power plant operations environment. Experience in operations & commissioning of thermal power plant.

Strong analytical and problem solving skills required to assess and respond to challenging situations in plant. Involved in monitoring and planning plant activities and creating MIS reports for management. Excellent written and oral communication skills. PROFESSIONAL OVERVIEW

SKILLS AND SPECIALIZATION

India Power Corporation LTD.

Designation: - Deputy Manager (1st Nov. 2017 to till date) Capacity: - 2*350 MW subcritical (1165 TPH, 16.7Mpa, 543Deg.c) Boiler: - Sub Critical, Single Drum, Controlled Circulation, Reheat, Pulverized Coal, front fired boiler Turbine make: - Harbin turbine Co. Ltd, 8th Extractions +condensing, DEH control system, HP/LP Bypass DCS: - Foxboro by Schneider Electric

JOB RESPONSIBILITIES:-

Handle the start-up / shut down, all types of emergency operations and troubleshooting e.g. a unit trip, Blackout operation, Turbine tripping, mill tripping, Fans tripping & BFP tripping. Prepared the unit for start-up including boiler lit up to pressure rising, vacuum-up to steam admission, rolling up to rated speed, unit synchronization and loading to full load. Performed changeover of standby equipment in order to ensure reliability of equipment, ensured safe operation, shut down and Isolation of system

Handle emergency situation of Desk operation confidently & continuously monitor parameter of Desk operation

Preparing SOP, daily generation Report and coal MIS. Inspects the unit's and its auxiliaries, electrical, mechanical, control and instrumentation equipment condition prior to start-up, during operations and after shutdown. Records all plant/auxiliaries operating data, including all alarms and protective devices being actuated and reports any deviation to the concerned maintenance Engineer for necessary action. Analysed the root cause for breakdowns by going thorough previous system parameters and Technical manuals and after thorough study of Tripping reports and DCS Trend graphs Co-ordinate with maintenance, personnel for ensuring violation, defect identification, work permit, trials clearance jobs prioritized by him.

Responsible to issue work permit through SAP (normal cold and hot work, confine space etc.) and cancel them on completion of the job.

Responsible for isolations and PTW LOTO System through on equipment and systems (turning off and locking of breakers during maintenance) to ensure safe and efficient operation. Operations documentations analysis for overall unit performance & Efficiency To ensure good housekeeping in the around the working area as an attempt to support safety health and environment.

Commissioning Responsibility:

Involved in Pre Commissioning & Commissioning activities of boiler and steam turbine (Boiler Hydro, Chemical & acid cleaning, steam blowing, Boiler light up). Generating execution plan for Testing and commissioning activities in sequence as defined. Identification of pending points before completion of trial operations. Taking trial runs of equipments with the co-ordination with other related departments as per given schedule Leading Turbine commissioning activities independently (turbine lube oil & Generator seal oil flushing, TG on barring gear, DEH oil system, BFP voith & pump, stator water flushing, Generator ATT & generator H2/N2/CO2 system commissioning as per procedure given by OEM. Commissioning of CCCW system, Condensate system, Critical piping, Gland steam system & Auxiliary steam system

Taking proactive steps & meticulous planning to meet the schedule on time. Supervise Interlocks & Protection checking of boiler and Turbine Preparing DCS check list, SOP of equipment, Technical diary & Punch list after testing. Planned key milestones and monitored activities, to achieve Commissioning targets. Reviewed daily progress and prepared action plan to remove backlogs. WORK EXPERIENCE (9 YRS)

ALSTOM POWER LTD. (CSAR Engineering & Consulting Services) Responsible for Turbine Commissioning and operation of 2*660 MW supercritical Thermal power station. From Mar 2017 to October 2017

Designation:-Assistant Manager (Turbine DCS Operation) Capacity: - 2*660 MW supercritical (2020 TPH, 24.7Mpa, 565Deg.c) Boiler: - BGR, HITACHI make, Super Critical Once through boiler, two stages Reheat, Pulverized Coal front wall fired boiler Turbine make: - 10th Extractions +condensing, DEH control system, HP/LP Bypass DCS: - Alspha

RELIANCE HR SERVICES (14th Feb, 2014 to 28th Feb, 2017) Responsible for BTG operation of 2x600 MW Damodar Valley Corporations, Ragthunathpur Thermal Power Station,WB Designation: DCS. Engineer

Capacity: 2*600MW, PF Boiler (2050 TPH, 17.47Mpa, 540Deg. C Boiler: -Sub Critical, Single Drum, Controlled Circulation, Reheat, Pulverized Coal Tangentially corner fired boiler Turbine make: - 8 Extractions +condensing, DEH control system, HP/LP Bypass DCS: - YOKOGAWA

ABHIJEET MADC ENERGY PVT. LTD (from 16th Aug, 2010 to 10 Jan, 2014) Worked as a BTG Desk Engineer of 246 MW IPP Thermal Power Plant, NAGPUR Boiler Make: - Wuxi, Type: CFBC, Capacity: 250 TPH, 98 kg/cm2, 540 deg c Turbine make: - Dongfang Turbine Company, Capacity: 61.5x4 MW, (China make) DCS: - Honeywell Experion C 300

Degree in Mechanical Engineering with 61% from Raisoni College, Nagpur in 2010 Diploma in Mechanical Engineering with 64.01% from NPN College, Nagpur-2007 HSSC Examination with 58.33% from V.M.V. College, Nagpur SSC Examination with 68.13% from Prashant high school, Nagpur ACHIEMENTS:

Appreciation letter for “MERITORIOUS CONTRIBUTION” Towards Successful & “Ahead of Schedule” commissioning of prestigious 4*61.5MW MIHAN POWER PLANT, NAGPUR Father’s Name : Mr. Marotrao Gawande Marital Status : Married Birthday : September 13, 1985 Nationality : Indian Gender : Male Linguistic Ability: English, Hindi, Marathi Notice Period : 1 month

DECLARATION:

I, Nitin Gawande, hereby declare that above mentioned information is true to the best of my knowledge and Belief.

Date: -

Place: - Nagpur Nitin M. Gawande

EDUCATION

PERSONAL DETAILS



Contact this candidate