CIRRICULUM VITAE
Post of applied for : QC / NDT CO-ORDINATOR / NDT MANAGER
Name : B. LOKANADHA RAO
Father’s Name : B. ATCHIYYA
Date of Birth : 26.03.1974
Nationality : Indian
Address for Communication : B. Lokanadha Rao,
Dr.# 20-1-83/11, NTR Colony,Demudu thota,
Near Chinaramasamy Temple, Gavarapalem,
Anakapalli, Visakhapatnam,AP,India-531002.
MOBILE -009***********
E-mail: ada13s@r.postjobfree.com
Passport Details;
Passport Number : Z 4355504
Date of Issue : 18-05-2018
Date of Expiry : 17-05-2028
Place of Issue : Visakhapatnam
Academic Qualification : SSC with First class
Technical Qualification : Diploma in Mechanical Engg.
ISO 9001-2008 LEAD AUDIOTOR
Professional Qualification : ASNT Level 3 in RT( Expired Nov 2018
) ASNT Level 2 in RT,UT,MPT,PT&RTFI
CSWIP B-GAS GRADE-3
Safety in industrial radiography certified by
Supreme council –doha –qatar.
Computer Skills : MS- Office, Word, Excel & Windows,Auto Cad
Language Known : Telugu, English and hindi
Experience ; 17 years in India and abroad
Conversant Codes : ASME SectionV,ASME Section VIII
Section IX ANSI B 31,3 B31.1,API 1104, API 650
Presently working in a Third party Inspection company ( Industrial Inspection services ) in local area.
.I HAVE MORE THAN ONE DECADE OF EXPERIENCE IN NDT,QC ACTIVITIES.MONITOR SUB CONTRACTOR NDT,QC ACTIVITIES,WITTNESS INSPECTIONS,REVIEW TE DOCUMENTS AS PER QAP.PREPARATION OF ITP'S AS PER ROJECT SPEC.RAISE AND CLOSE NCR'S.DIMENSIONAL INSPECTIONS, WQT,PQR,DESTRUCTIVE TESTING WITTNESS. NDT REQUEST PREPARATION. COVER % NDT AS PER PROJECT SPEC. UP DATE THE DATA OF INSPECTION .RT FILM INTERPRETATION AS PER APPLICABLE CODES AND STANDARDS.UT CROSS CHECK. CORROSION MONITORING.WELD VISUAL INSPECTION. PMI, PWHT, HARDNESS WITTNESS AND REVIEW THE REPORTS. THIRD PARTY NDT TECHNICIANS APPROVAL. PAINTING AND 3 LPE COATING INSPECTION ACTIVITIES. STAGE WISE INSPECTION SURFACE ROUGHNESS AND UP TO FINAL COAT DFT CROSS CHECK AS PER APPROVED ITP.DIMENTIONAL INSPECTION OF THE EQIPMENTS .MATERIAL RECEIVING INSPECTION
COMPANY NAME ; Tecnicas Reunidas
Duration ; OCT 2014 TO SEP 2015
DESIGNATION ; QC /NDT LEVEL 3 COORDINATOR
Monitor QC NDT activities of sub contractor. Follow up Local atomic energy regulation board, s for RT Implementation of safety procedure as per the Local radiation Safety regulations and . Follow up ITP. Attend minutes of meetings. Raise and close the NCR’spermissable parameter’s. RT film interpretation as per the applicable codes and standards. NDT team management of the third party NDT team. Review the procedures and method statements. Maintain the daily progress of overall NDT Third party company wise project the backlog and repair % project wise and welder wise.Monitor PWHT team review the charts.
COMPANY NAME ; SNAMPROGETTI SAUDI ARABIA CO.LTD
Badge No; ; SP 2597
DURATION ; DEC 2012 TO Apr 2014
DESIGNATION ; QC / NDT INSPECTOR
NDT Inspection activities for SAFCO-5 ( Saudi Arabia Fertilizer company ) Review the project specification and modify the NDT procedures as applicable spec. requirements. Preparation of ITP . review the RT films attend minutes of meetings .Demo tests for the NDT companies approval. Verify applicable standards for approval of NDT dark room and viewing facilities.Attend site inspections.
COMPANY NAME ; DAELIM SAUDI ARABIA LTD
DURATION ; SEP 2009 TO JUNE 2012
DESIGNATION ; QC / NDT L-2 INSPECTOR
Attending witness Inspection Various Pressure Vessels, Static Equipments, Process Pipings, Fabrication Valves, Line Pipes for NDT .Witnessed Hydrotest.
Raise and close NCR’s. Material receiving and data sheet review for coating
Review RT films as per applicable codes and standards.
Monitor and update all sub contractor’s NDT activities. Coverage the NDT % as per project spec. Monitor the welders repair %by NDT. Update the all NDT inspection activities in CIMS( Construction Integrated management System ).Submit the reports with Auto cad sketchs.
Co-ordinate with the PWHT team for the H2S Line.
Identifying the Incoming Materials by the PMI Test.
COMPANY ; JACOB INSPECTION,CHENNAI( OMAN SHUT DOWN )
DURATION ; JULY 2009-AUG 2009
DESIGNATION ; QC NDT INSPECTOR
Monitor all shut down NDT activities of Sohar urea and chemical industries
In oman(a fertilizer plant ) . Wittness and review .Equipment and exchagers inspection. Piping and
Pressure vessels.vibration analysis, gauging survey, mpt,dpt.UT
COMPANY NAME ;GERMANISCHER LLOYDS,DELHI.
DURATION ;DEC 2008 TO MAY 2009
DESIGNATION ;NDT INSPECTOR
WORKED AS 3RD PARTY INSPECTOR FOR IOCL PIPE LINE PROJECT IN PIPE MANUFACTURING DIVISION.TO MONITOR THE ALL INSPECTION ACTIVITIES DIMENTIONAL, DESTRUCTIVE,NDT,HYDRO, RT FILM RIVIEW. 3 LPE coating stage wise inspection for 18 “ Dia cross country pipe line project for SOC Iraq.
Company Name ;Eastern Bechtel Company ltd,Abudhabi.
Duration ;5th Apr 2008 to NOV 2008
Designation ; UT INSPECTOR
Carry out UT INSPECTIONS FOR CORROSION MONITORING SURVEY. RT film review. Preparation Monitoring sub contractor NDT activities. Wittness for hardness testing,PMI,PWHT chart review.
Company Name ;PEMCO INSPECTION COMPANY,DOHA-QATAR
Duration : Nov 2006 – Feb 2008
Designation : N.D.T. TECHNICIAN
To done N.D.T. for offshore wellhead jackets and pipe line Corrosion maping and weld scanning by U.T. in production stations for QATAR petroleum offshore. Prepare the report s with skectches
Company Name : National Petroleum Construction Co, (NPCC) Abudhabi, U.A.E
Duration : July – 2006 to Oct – 2006
Designation : N.D.T TECHNICIAN
TO CARRY OUT NDT for Offshore Jackets construction Projects .To done the all inspection activities as per the client QCP.
Company Name : Arab ship Building & Repair Yard Company
KINGDOM OF BAHRAIN
Duration : Oct 2005 to April 2006
Designation : N.D.T. TECHNICIAN
To carry out rt,ut gauging,mpt of on-boat as per the class requirements.
Company Name : Sievert International Inspection Company WLL
DOHA – QATAR & SULTANATE OF OMAN
Duration : october 2004 to Sep 2005
Designation : UT Technician / QC Inspector
Well head jackets maintenance,pipe line corrosion maping by ultrasonic testing.
Worked as UT Technician for Qatar Petroleum Offshore Halul Island and PS 2
Worked as QC Inspector for 20 “ dia cross country pipeline project in oman.
Company Name : Integral Services Company WLL
STATE OF KUWAIT.
Duration : December 2003 to July 2004
Designation : Multi Disciplined NDT Technician
Ultrasonic Flow Detention of Exchangers and vessels of Alkalation and FCC units shutdown in Kuwait National Petroleum Co. (KNPC)
Company Name : Quality Industrial X-Ray Pvt. Ltd. Mumbai.
Duration : May 2002 to December 2003
Designation : Multi disciplined NDT Technician
Ultrasonic Testing of Spiral Welding in pipe Manufacturing Division of PSL Ltd Gujarat in Gandhidam.
Company Name : X-Ray Engineering Co. Mumbai.
Duration : Feb 2001 to May 2002
Designation : Multi disciplined NDT Technician
Inspection of casted Refinery valves in M/s. Chemtrols Ind.Pvt.Goa.
Co- Ordinate the shutdown inspection in zuwari Agro Chemicals,( A birla group fertilizer plant in Goa )
Company Name ; Sievert India ltd.
Duration ; jan 1999-jan-2001
Designation ; Multi discipline NDT Technician
Inspection of welding by rt,ut,mpt and pt
Company Quality Evalution services.
Duration sep 1996 to oct 1998
On-job training for all NDT Inspection activities. Coromandal fertizers shutdown activities.
Saudi Arabia. ( B. LOKANADHA RAO)
Date:2nd SEP 2019.