I & C Technician
ABENGOLA SOLAR ONE - Gila Bend, AZ
April 2018 to Present
ASO is a 300 MW solar fueled steam generation power plant. It consists of two Siemens steam turbines and all peripherals. I was part of the startup and commissioning team. After startup I have been the senior I&C tech responsible for the maintenance and predictive maintain for the plant. I&C Technician
PG&E capital project
January 2019 to December 2019
on their Gas Distribution system upgrade. I am responsible for QA/QC for the installation, implementation and commissioning of ABB XRC G4 Totalflow
RTUs and all instrumentation associated with the RTU. I program the RTU per PG&E standards and calibrate all instrumentation to the NIST. Upon commissioning, I also educate PG&E union employees on these field units and answer any question or concerns. I & C Technician
FPL Martin Fuels Terminal
October 2016 to April 2018
Contract Position)
Worked with EIU on the installation of a three compressor gas station power package. I was responsible for bench calibration of all associated instrumentation and control devices. I was in charge of providing to the client, NIST calibration records and building loop packages to be approved by FLP. After construction my responsibility shifted to loop check out and startup. I & C Technician
DOW Chemical - Texas City, TX
May 2015 to October 2016
Contract Position)
Duties included but were not limited to Daily PMS and maintenance work orders. Also responded to Operations emergency work where we acted as a fix it now team. Responsibilities were too responded to the entire Texas City facility.
I & C Technician
Wynnewood refinery - El Paso, TX
February 2012 to May 2015
October 2009 to February 2012
I was a member of the Process Control Team where I maintained three Boilers and their Steam turbines as well as BOP. Installed, maintained, and calibrated all field devices up to their control systems. I also maintained their Foxboro I/A DCS and Allen Bradley PLC systems. In my time there I was the lead-tech responsible for upgrading two of the units to Allen Bradley PLC control. I performed all Field Engineering, purchased all new transmitters, Valve positioners and made J-Box Drawings with engineering group assistance tuned the two boilers from the ground up. I also was responsible for outage coordination and removal and reinstallation of all turbine telemetry. I was also a shared resource at our sister plant in Newman TX. Newman has three steam boilers two times two GTS with their associated HRSG. I would be utilized on an as needed basis. I & C Technician
Wynnewood Refining
January 2012 to December 2012
2012 Turnaround (Contract Position)
Duties included but were not limited to turnaround activities, startup support, maintenance work orders where I completed a variety of instrumentation related tasks. I was responsible for instrumentation repairs, calibration and associated loop testing.
I & C Technician
I & C Technician Honeywell - Craig, CO
August 2005 to October 2009
TRISTATE is a three unit 1350 Mw base loaded coal plant. I was responsible for all process related devices. Which encompasses our Honeywell TDC-3000 down to all remote transducers and their control devices. Our DCS system has HPMs, LMS, ECNs, ECNs and a variety of digital modules that comprise our overall system.
I & C Technician
Coors Brewery - TRIGEN Colorado
June 2002 to August 2005
Tri gen is a Co-Gen operation where we produce 60 MW of power as well as 800lb, 400lb and 50lb steam for the Coors brew process. I am responsible for the maintenance and calibration of all standard instrumentation and our Fisher DCS. Tri gen has five boilers, three of which are coal/gas, three GE generators and their associated balance of plant systems. I also maintain the CEMS and all various analytical measuring devices including the ION exchange water treatment double bed. In addition, I have experience with Allen Bradley plc-5 plc-2 and plc-1774 using ICOM and RSLOGIX software. I & C Technician (Contractor/Field Service), VECO Rocky Mountain Engineering Worked as an in-town field tech where I serviced a variety of complexes such as Lockheed Martin, Goodyear Aerospace, Gates Rubber, Hebert Environmental, RPI Pharmaceutics, Tri gen, Sithe Power and HS Resources. Duties included calibration troubleshooting and repair to any and all process instrumentation.
I & C Technician
Seabrook Power Station - Seabrook, TX
December 2000 to June 2002
Duties included but were not limited to maintenance work orders where I completed a variety of instrumentation related tasks. I was responsible for instrumentation repairs, calibration and associated loop testing.
I & C Technician
Florida Power and Light - Power - Florida, US
October 2000 to November 2000
and Light
Duties included but were not limited to maintenance work orders where I completed a variety of instrumentation related tasks. I was responsible for instrumentation repairs, calibration and associated loop testing.
I & C Start-up Technician
General Electric International TVA
September 2000 to October 2000
Contract Position), General Electric International TVA Worked as start up technician on four, 80MW Frame 7 GE gas turbine units. I was responsible for I/O checkout to the Mark 5 PLC and troubleshooting all control loops associated with the particular electric generating units.
I&C Technician
Instrumentation and Controls Department FirstEnergy Corp. May 2000 to September 2000
Duties included but were not limited to maintenance work orders were I completed a variety of instrumentation related tasks. I was responsible for instrumentation repairs, calibration and associated loop testing.
I&C Technician
Maintenance Instrument Group - Sequoyah, OK
March 1999 to May 2000
Experience includes work on the primary and auxiliary systems where I carried out surveillance instructions and work orders. I primarily worked on auxiliary feedwater ATVs and control valves. Which I also was involved with Airforce testing of the feedwater ATVs. I performed troubleshooting, calibration and repair of all instrumentation when needed.
I&C Technician
Instrumentation and Controls Department, Phelps Dodge February 1997 to March 1999
Responsible for maintaining all instrumentation and process control equipment. This equipment included, but was not limited to the following: temperature, pressure, flow, level, pH, conductivity, H2 analyzers, gas chromatography, IR units, controllers and end devices. I also maintained all ISO 9001 instrumentation as well as their appropriate documentation. In addition I also maintained a yearly budget of $100,000.00, which I used for shop procurement.
I&C Technician
I&E Design Department
August 1995 to February 1997
Worked on the Olin Chemical Ketone Plant DCS conversion. I was accountable for in depth walkdown of all P&IDs, detailed instrument loop design, drafting using Auto Cad 13 and all other responsibilities necessary to produce project drawings in a timely manner. I&C Technician
Maintenance Instrument Group - Sequoyah, OK
March 1993 to August 1995
Worked on primary and auxiliary systems where I carried out surveillance instructions, preventative maintenance and maintenance work orders. Including calibrations, troubleshooting, testing and repair of plant instrumentation.
I&C Technician
COOP
October 1991 to March 1993
TAN Watts Bar
Worked on the time response team, where we checked the response times of plant process control devices. I also worked on the primary and auxiliary systems were I carried out outage surveillance instructions including calibration of: flow transmitters, level transmitters and pressure switches. COOP
I&C Technician
Process Controls Systems Tech
September 1990 to October 1991
Where I was responsible for installing, maintaining, troubleshooting and repairing process control equipment including all instrumentation, (pneumatic, analog and digital/microprocessor control equipment) valves, actuators and various control circuitries. I&C Technician
TU Electric Comanche
April 1988 to September 1990
This position was held at an apprentice level. Responsible for working with in house technicians, where we performed variety of scheduled outage tasks. These tasks ranged from electronic and pneumatic transmitter calibration, level, flow and temperature devices. I & C Technician
PG&E
September 1986 to April 1988
COOP
Education
Associate in applied science
Bishop State Community College - Mobile, AL
June 1997 to May 1999
Skills
• Chromatography
• E&I
• Distributed Control Systems
• Manufacturing
• Microsoft Office
• Quality control
• Electrical experience
• NEC
• Hand tools
• Power tools
• Calibration
Certifications and Licenses
OSHA 10