Post Job Free
Sign in

Electrical Engineer O M

Location:
Doha, Qatar
Posted:
August 25, 2024

Contact this candidate

Resume:

PRANAV RAJU

Doha, Qatar ***********@*****.*** +974-******** www.linkedin.com/in/Pranav Raju

ELECTRICAL ENGINEER-(UPDA –REG NO-26654)

POWER PLANT DATA-CENTER FACILITY MANAGEMENT

Dedicated professional with 10+ YEARS of experience in electrical operation & maintenance and history of meeting company goals utilizing consistent and organized practices. Skilled in working under pressure and adapting to new situations and challenges to best enhance the organizational brand. Organized and successful at managing multiple priorities with a positive attitude. Willingness to take on added responsibilities to meet team goals.

WORK EXPERIENCE

SERVTECH INTERNATIONAL – DOHA, QATAR 07/2023 - PRESENT ELECTRICAL ENGINEER-(O&M)-FACILTY MANAGEMENT

Planning and Execution of preventive and corrective maintenance jobs for CUMMINS, PERKINS, CATERPILLAR, and SDMO, diesel generators,LV PANELS and ATS

Handling projects of clients like, KAHRAMAA (LTC-1989-2023), HIA, QATAR ENERGY & QAFCO.

Planning and Execution of Top Overhauling of Generators.

Completed training for PARTIAL DISCHARGE MONITORING SYSTEM-(QUALITROL)

Collaboration with site team to quickly resolve client complaints with appropriate action.

In charge of maintenance department for generators, BMU and Chute System Guiding/leading the maintenance team and implementing the best maintenance strategy

Reviewing tenders and manage the to submit the best technical and commercial offers

Attending QCDD inspection and submitting report as per requirement.

Pricing and estimation of PM activities and LPO. RELIANCE JIO INFOCOMM LTD – KERALA, INDIA 12/2021 – 06/2023 ELECTRICAL ENGINEER-(O&M) - DATA CENTER

Operation and Maintenance of CUMMINS & PERKINS GENERATORS, DELTA make SMPS SYSTEM-120 KW and COSLIGHT BATTERIES(Li-ion), 11 KV & 415 V SWITCH GEAR with ATS

Operation and Maintenance of PRECISION AIR CONDITIONING SYSTEM (STULZ & EMERSON )

Resolved problems, improved operations and provided exceptional service.

Created management reports outlining important facility statistics.

Preparing documents for audits like INFOSEC,DOT,HSE and other statutory requirements

Conducted regular reviews of supplier relationships for quality and cost analysis.

Managed building and system start-up to accomplish project goals, specifications and contract requirements.

Ensure 100% uptime of utility equipment and network facilities.

Track and close utility alarms within service level agreement. SERVTECH INTERNATIONAL – DOHA, QATAR 08/2018 – 12/2021 ELECTRICAL ENGINEER-(O&M)-EMERGENCY SYSTEM

Operation and Maintenance of CATERPILLAR GENERATORS IN HAMAD INTERNATIONAL AIRPORT-CENTRAL UTILITY PLANTS.

Operation and Maintenance of CUMMINS -QSK-60-2000 KVA PRIME GENERATORS IN BANANA ISLAND RESORT DOHA.

Performed maintenance procedures and repairs on existing electrical products and systems Guiding/leading the maintenance team and implementing the best maintenance strategy.

Evaluated electrical installations and systems to isolate faults and implement corrective actions.

HYUNDAI HEAVY INDUSTIRES –SAUDI ARABIA 12/2014 – 03/2018 ELECTRICAL ENGINEER-(TESTING & COMMISSIONING)-POWER PLANT

Testing and Commissioning of 13.8 KV, 6.9 KV, 4.16 KV & 480 V (MV & LV) SWGR panels.in Tihama Power Generation (SAUDI ARAMCO) & Shuqaiq Steam Power Plant

(SAUDI ELECTRIC COMPANY)

Handled testing kits like OMICRON CMC 256,356, OMICRON CT ANALAYZER, MEGGER, CBANALAZER PME-500 TR, PROGRAMMA KIT, VANGUARD INSTURMENTS, OCR TESTER.

Knowledge in Transformer protection, Differential Protection & REF, Bus Bar protection scheme.

Testing of interlocks and intertrip sequence between Power Plant and GIS.

Pre-Commissioning & commissioning of Switch gears and substations.

Configuration and Testing of GE make F60 relay.

KERALA STATE ELECTRICITY BOARD –KERALA, INDIA 04/2013 – 07/2014 ELECTRICAL ENGINEER-(O&M)-SUB STATION

Troubleshooting activities of HV (Outdoor) & LV (Indoor) Equipment's,

Overhauling of LT motors

Coordination with senior engineer to complete the scheme checking

Conducted system testing.

Monitored the performance of the system and made necessary adjustments to optimize

Operation and Maintenance of 220 KV Air Insulated Substation. EDUCATION

BE, ELECTRICAL AND ELECTRONICS- ANNA UNIVERSITY CHENNAI-(2009-2013) PROFESSIONAL SKILLS

FACILITY AND EQUIPMENT MAINTENANCE TECHNICAL SUPPORT PROJECT MANAGEMENT CIRCUIT DIAGNOSTICS TIME MANAGEMENT OPERATION AND MAINTENANCE PLANNING EXECUTION TEAM WORK COMMISSIONING SAFETY STANDARDS AND REGULATIONS PROBLEM-SOLVING AND ANALYTICAL SKILLS PROJECT MANAGEMENT COMMUNICATION SKILLS MAINTENANCE AND TROUBLESHOOTING PREDICTIVE MAINTENANCE TECHNIQUES ASSET MANAGEMENT TEAM LEADERSHIP AND TRAINING.

AWARDS AND HONORS

MMUP-UPDA –REG NO-26654

Valid with trainee grade.

BEST PERFOMACE AWARD – HYUNDAI HEAVY INDUSTRIES-SAUDI ARABIA

Recognized for outstanding service to in commissioning activities. LANGUAGE COMPETENCIES

English: fluent(speaking, reading, writing)

Hindi: fluent (speaking, reading,)

Malayalam : native

Tamil : fluent(speaking)

REFERENCES

Mr. SHIBIN REGHU CLIENT ELECTRICAL LEAD ENGINEER, TIHAMA POWERGENERATIONCOMPANY)-SAUDIARABIA ******.*****@***********.***

Mr. SANG CHUL SHIN MANAGER ELECTRICAL MANAGER, HYUNDAI HEAVY Industries. Ltd ********@***.**.**

MOHAMMAD OMAIS MANAGER DEPARTMENT MANAGER)-SERVTECH INTERNATIONALQATAR *.*****@********-**.***

DECLARATION

I hereby declare that the information and facts stated above are true and correct to the best of my knowledge and belief



Contact this candidate