David Kitchen
**** ***** ******,********** ********,23324
Phone:757-***-****
Email to:*************@*****.***
First Class Marine and Industrial Electrician/
Communications Installation Technician
SUMMARY OF QUALIFICATIONS:
Experienced and knowledgeable Electrical/Communications installation technology professional seeking to contribute training and acquired skills within a Tier One Technical Support and customer support role. Works well independently,or in a group setting providing all facets of Electrical and communications support such as troubleshooting, installations, and maintenance. In-depth knowledge and understanding of numerous industry Electric Plant Installation standards and systems. Skilled in providing Customer and End-User Help and Support. Easily identify and resolve technical issues and concerns. Excellent communication and presentation capabilities. EDUCATION:
U.S. ARMY Signal Center,Ft. Gordon, Augusta,Georgia. 3/1985 31E Field Radio Repairer- Electronics Communications Technician Credits Earned: 80 Semester hours
Major: Information Technology/Communications-Electronics Components Repair PROFESSIONAL EXPERIENCE:
Shipyard Staffing, 415 W York Street Suite 102 Norfolk, VA 23510 (2/2023 – Present-on call)
Information Technology Technician
Performed diagnostics and troubleshooting of system issues;Documented customer service requisition tickets/resolutions,and documented Provided installation testing and quality control testing of equipment inventory.
Tidewater staffing, Chesapeake, 1000 Poindexter Street, Chesapeake, VA 23324,
(1-/2023-2/2023)
First Class Marine Technician
Provided onsite field support and technical training on hardware to end users. Documented deficiencies with associated electrical and electronic hardware. Provided resolutions to difficult troubleshooting, and provided overall assistance in daily administration. Performed set-up, break-down, and transport of agency equipment on an as-needed basis.
Allied Research Technology 500 Freeman Avenue Chesapeake VA 23324 (on call) 1-757-***-****
OSHA certified fire watch and trades assistant for various A/R Research customers. My professional history in the electrical,communications and installation field spans more than 27 years. I have worked for such leaders in the industry such as MILCOM Systems-(1990-2000). Tradesmen International as a Trades Professional to various customers such as TECNICO-Various time-frames,General Dynamics/NASSCO San Diego,BAE Systems,Standard Calibrations-Chesapeake,Virginia as a 1st class marine Electrician.LYONS Shipyard as a 1st class Marine electrician. LANGUAGES:
• English
PROFESSIONAL PUBLICATIONS:
• Extreme Technology
• Linux Magazine
•IEEE Standards.org
ADDITIONAL INFORMATION:
• Astute ability to think critically and to initiate appropriate emergency procedures.
• Skilled to understand and describe electrical plant engineering technology, programming, and customer support procedures.
• Skilled in using Word, Excel, LibreOffice and other products. Relevant Skills: Installation,troubleshooting main power switchboards,Frequency Converters,power panels,degaussing controllers and connection panels,Transformers- Air/convection,liquid filled,composite waterproof types. Various lighting systems to include High pressure Sodium,LED lighting,Fluorescent lighting. Installation of commercial restaurant equipment and installation of the necessary power interconnecting sub systems. Installation and troubleshooting of fire control and suppression sensors. Motor controllers;low and high voltage(AC and DC ) including Hybrid multi stepping types. Motor operated valves. Tank level indicators(aka.TLI’s)- Float and Radar types. Refrigeration Controllers,GPS-WRN6,7/US NAVY,TOMAHAWK wiring and connector building and repair(Multi-Pin),Commercial Data rack installation- A&J/LINIER,Remote surveillance cameras and US Navy's Ship Self Defense System(SSDS). Fiber optics installation/testing and repair of US Navy’s IT 21Network,Switches,triple backbones. Wireless antennae matching for the military’s DC(Damage Control) WIFCOM(Wire Free Communications Systems) to PVPCS(Protected Voice Personal Communications System) I use a variety of test equipment, to include Multimeters,light meters,Meggers/resistance testers,spectrum analyzers,frequency generators,Oscilloscopes,moisture Meters.
This resume’ is a brief of the large container of knowledge I have used and accumulated over 27+ years of working in the commercial/industrial field. If I encounter something new, I have the background experience to draw upon to comprehend and create implementation measures. I am familiar with Differing types of installation drawings to include Technical,structural,detail,finishing drawings. I enjoy my work and the challenges it brings. To know that my contributions will make a difference and what I contribute may stand as a testament to time. To work as a team player with others in the field in achieving a goal through all challenges and to teach those with less experience in order to strengthen my company’s competitive edge.