Post Job Free

Resume

Sign in

Medical Physicist Cancer Center

Location:
Florin, CA, 95828
Posted:
April 20, 2024

Contact this candidate

Resume:

RAJESH SUBRAMANI

(Current city: Bakersfield, CA, United State of America. – 93311, Mob: +1-304-***-****, ad445y@r.postjobfree.com) SUMMARY

To contribute strong clinical and interpersonal skills, as well as experience, in a Senior Medical Physicist capacity. Able to work on own initiative and as part of a team. Dedicated to maintaining high quality standards. SKILLS

• All aspects of Treatment Planning and Quality

assurance for Radiation Oncology.

• Linac Experience - Varian True Beam,

Tomotherapy- HDA & Radixact X9, Cyber

Knife VSI, Siemens Artiste, Elekta Versa HD.

• QA Tools- IBA, PTW, Sun Nuclear & Standard

Imaging.

• Acceptance Testing & Commissioning of Medical

Linear accelerators, Tomotherapy & Cyber

Knife- VSI

• Treatment Planning systems- Precision (CK and

Tomotherapy) and Eclipse & Monaco

CLINICAL EXPERIENCE

Clinical Medical Physicist (Rio Brao Cancer Center, Bakersfield.CA and PMD : Aug 2021-Till

• Worked with Cyber Knife VSI and Elekta Infinity treatment machines. R&V is MOSAIQ.

• Responsible for Cyber Knife treatment planning using Precision treatment planning system.

• Performed Cyber Knife Daily, Monthly & Annual QA (St, Mary’s Medical Center, Huntington, WV)

• Currently working with Elekta Versa HD and Monaco TPS V6.0.0 (RIO BRAVO CANCER CENTER- Bakersfield, CA.)

• Perform the Contouring of Organ at Risk and normal tissue and Also Performs IMRT, VMAT, SRS, SBRT & 3DCRT using Monaco TPS. Remote support for PMD other Sites Eclipse planning

& Aria. Support in Cyber Knife Plans and Plan review using Precision TPS.

• Responsible for Linac Monthly QA, Patient Specific QA using Arc CHECK. Experience in MIM software for Contouring.

• Responsibilities include weekly Chart check, Independent MU Calculation using mobius software. Chief Medical Physicist Cum RSO: HCG ICS Cancer Centre Mumbai, MH, India May 2018-Jul 202.

• Worked with Radixact X9-Tomotherapy and Cyber Knife VSI Treatment machines.

• Responsible for Tomotherapy and Cyber Knife plan using Precision Treatment planning system.

• Experienced in Special Treatment TBI, CSI using tomotherapy, Cyber Knife SRS & SBRT

(6DSkull, Fiducial, Synchrony, Xsight Lung).

• Perform the Cyber knife and Tomotherapy QA using PTW, Standard Imaging dosimetric equipment. Patients specific QA with PTW OCTAVIUS 1500 & PTW SRS1000 Detector for Cyber Knife Pts QA.

• Maintaining records of all radiation worker dose, QA test of the instrument which are need to be produced while inspection of Radiotherapy Department of Institution by AERB personnel. Medical Physicist:

Healthcare Global Enterprises Ltd Bengaluru, KA, India Sep 2011-Apr 2018

• In Healthcare Global Enterprise worked with Siemens Artiste CT on Rails & IN line K-view, Tomotherapy HDA, Varian True beam, Unique Power & Cyber knife G4 treatment machines.

• Handled R&V system Mosaiq v2.3 and Aria v13.5.

• Involved Treatment Planning -3D-CRT, IMRT, VMAT, SRS, SRT using Eclipse TPS V11.0& V13.

• Tomotherapy Planning using Volo V5.01 Treatment Planning station.

• Involved All Quality Assurance -Periodic QA (Daily, Monthly, and Annual) TPS QA, MLC QA for all machines with IBA and PTW Dosimetric equipment.

• Involved patient Specific QA (IMRT QA) with Sun nuclear MapCHECK 2 and PTW Array detector.

• Performs Weekly Treatment chart check.

• Involved for Beam data collections and TPS commissioning HCG other centers.

• Performed Treatment planning for HCG remote sites & overseas.

• Brachytherapy planning using Oncentra Master Plan TPS. Nucletron Microselectron Unit. EDUCATION

M.Sc.: Medical Physics

Bharathidasan University (Accredited with A+

Grade by NAAC) Tiruchirappalli, Tamil nadu,

INDIA June-2011

B.Sc.: Physics

Karur Govt Arts College Karur, Tamil nadu, INDIA May-2009 CERTIFICATION & LICENSURE

Certified Radiological Safety Officer (RSO-Level III) By RP&AD of BARC. Mumbai, India. ACCEPTANCE TESTING AND COMMISSIONING EXPERIENCE

• Acceptance Testing & Commissioning of Varian Unique, HCG -Cancer Centre,Gulbarga. India. Aug2015.

• Acceptance Testing & Commissioning of Varian True Beam at HCG-Cancer Center, Cuttack.Feb2016.

• Commissioning of ARTISTE In Line K- View HCG, Bangalore.April2016.

• Acceptance Testing & Commissioning of Radixact X9-HCG Cancer Center, Mumbai. June2018.

• Acceptance Testing and Commissioning of Cyber Knife VSI, HCG Cancer center, Mumbai.Sep2019. PRODUCT TRAINING

• Tomotherapy Radixact X9 Physics &Precision Treatment Planning for Tomotherapy System with iDMS – Hamburg, Germany. March 2018.

• Varian Advanced Technique Physics course IMRT/Rapid arc-Cham, Switzerland. Aug 2016.

CLINICAL ACADEMIC WORK

• Oral- 02 A DOSIMETRIC COMPARISION OF INTESNITY MODULATED RADIATION THERAPY

(IMRT) WITH FLATTENING FILTER BEAM vs FLATTENING FILTER FREE BEAM FOR CA- CERVIX- ORAL.AMPICON- TNPY, INDIA-2017.

• PP-73 ACCEPTANCE TESTING AND COMMISSIONING OF RADIXACTTM X9 TOMOTHERAPY UNIT-INITIAL EXPERIENCE-Poster.AMPICON-2018, CHENNAI.INDIA.

• P52-LEFT BREAST IRRADIATION WITH TOMOTHERAPY: TOMODIRECT OR TOMOHELICAL?

- A DOSIMETRIC ANALYSIS-POSTER.AMPICON-2017, JAIPUR, INDIA.

• DOSIMETRIC AND CLINICAL ADVANTAGES OF 3D CONFORMAL HELICAL TOMOTHERAPY OVER TOMOTHERAPY BOX FIELD TECHNIQUE FOR CERVICAL CANCER- Selected for best POSTER competition -PP-60673, AAPM-2022.

REFERENCE

Dr. Harold D'Souza, PhD, DABR

Senior Medical Physicist

MedStar Washington Hospital, USA.

Email: ad445y@r.postjobfree.com Mob: +1-908-***-****. SIGNATURE

I hereby declare that all the details furnished above are true to the best of my knowledge. RAJESH SUBRAMANI

Clinical Medical Physicist

Precess Medical Derivatives, NJ

Rio Bravo Cancer Center, Bakersfield, California.



Contact this candidate