Post Job Free

Resume

Sign in

Electrical Engineer Power Supply

Location:
Jeddah, Mecca, Saudi Arabia
Salary:
8000 SR
Posted:
March 04, 2024

Contact this candidate

Resume:

CURRICULUM VITAE

PERSONAL INFORMATION:

Engr. Moinuddin

Position: Electrical Engineer

Mob: +966-*********

Email id: ad3350@r.postjobfree.com

Address: Al Mutnazahat Kilo 10, Jeddah KSA

KSA Driving license: Yes

Saudi Council of Engineers id: 614266

Objective:

Desire to work at a challenging and strategic position in a professionally managed, progressive organization as an Electrical Engineer of King Saud bin Abdul Aziz University Health & Sciences Medical city Jeddah KSA, in Zahran Facilities management. summary of experience:

Over 12 Years experienced in the field of electrical engineering. Operation and maintenance of building power system emergency power supply. Maintenance of uninterruptible power supply

(UPS) up to 300 KVA. battery installation and its operation from maintenance bypass to online Worked in Aluminum refinery for Construction of 230 KV substation, 34.5 KV s/s Erection, pre- commissioning Testing of electrical equipment that includes substation power control center panels, switchgears, Earthing, lightning, motor solo run Test Preventive and break down maintenance of HT/LT Switchgear, HT/LT Transformer and panels. trouble shooting of HT/LT switchgear.MV & LV MCC and UPS & Battery bank system. Inter connection wiring diagram, inter lock circuit and inter trip testing between substation to substation. Electrical instrument loop testing of motor through DCS and UMC relay setting. TOTAL EXPERIENCE: OVER 12 YEAR

Experience: 1

CURRENT COMPANY: Zahran Facilities Management Jeddah KSA From,01 July 2020 TO till date.

CURRENT POSITION: Electrical Engineer

PROJECT: King Saud Bin Abdul Aziz University

Health and Sciences Medical City Jeddah ksa.

Current Job Profile:

Major maintenance on UPS (Uninterruptible power supply) system involves more comprehensive and extensive task compared to regular maintenance. Major maintenance is typically conducted at longer intervals and is aimed at ensuring the UPS’s continued performance and reliability over an extended period. Task performed during major maintenance on UPS system.

Visual inspection: conduct a thorough visual inspection of the UPS system, including its components wiring and connection. Look for sign of physical damage, loose connection, or overheating. Check Ground connection tightness, check all battery terminal tightness. check battery voltage. Check proper fixation of each branch breaker, check breakers labeling.

Battery Testing: Test the UPS batteries assess their health and capacity. This includes testing the voltage, internal resistance or performance load tests to determine how long the battery can sustain power during an outage.

Battery testing by battery analyzer Fluke BT521 finding highly impedance faulty battery.

Load Bank Testing: For larger ups system perform load bank testing to simulate real – world operating conditions and verify that the ups can handle its rated load.

Battery Replacement: Battery testing by battery analyzer Fluke BT521 if find high impedance battery take corrective action to replace faulty battery. during the battery replacement UPS must be maintenance bypass mode without interruption of service.

Cleaning: Dust and debris can accumulate inside the UPS, affecting the cooling efficiency and over all performance. Clean the internal components, cooling fan, and air vents to ensure proper ventilation.

Replacement of Component: inspect and replace any time out or faulty components, such as capacitor. Cooling fan, or damaged circuit board. using genuine replacement part is crucial to maintain the UPS reliability.

UPS Bypass Test: Test the UPS’s bypass functionality to ensure a seamless transfer of power in case of ups failure or under maintenance.

Operation of ups: after replace the battery and troubleshooting the alarm take corrective action.

Data Center UPS: operation and maintenance of Data Center Parallel ups. Periodically battery bank analyzes and replace faulty battery.

Environmental Checks: Ensure that the ups are working in an appropriate environment with proper temperature and humidity levels check for any issues that may arise from the operating environment, such as excessive heat or dust.

Alarm & Log Checks: Review the ups system alarm logs to identify any historical issue or warning massage. clear any false alarm and address any recurring issues.

Documentation and Reporting: Maintain details records of the maintenance activities performed, test results and any identified issues. These records are use full for future reference and warranty compliance.

ATS & UPS: Functional understanding with UPS, and ATS. Normal and emergency supply.

Handling of APC Schneider UPS up to 300 kva, general electric up to 300 kva, socomec up to 2000 va.

Performed preventive maintenance, remedial service, and emergency repair service on various brand ups system

Integration of APC Schneider galaxy 5000 and 7000 ups with BMS system.

configuration SNMP (simple network management protocol).

Scanning of ups input and output data.

Experience: 2

COMPANY: Jash Technical Services CO. Ltd KSA.

From 07 Jan 2018 to 30 Jun 2020.

POSITION: Electrical Engineer

PROJECT: King Saud Bin Abdul Aziz University

Health and Sciences Medical City Jeddah ksa.

Current Job Profile/ UPS Maintenance:

Familiar of PPM (plant preventive maintenance).

Preventive Maintenance of ups system of emergency supply.

Performed preventive maintenance, remedial service, and emergency repair service.

Uninterruptible power system (UPS) APC Schneider up to 300 kva, general electric up to 300 kva, socomec up to 2000 va. maintenance of data center parallel ups250 kva.

Operation of ups after replace the battery and troubleshooting the alarm take corrective action.

Installation of new ups.

Maintenance of emergency techno ware system and central battery system

Battery testing by battery analyzer BT5021 finding faulty batter and take corrective action.

Testing of internal resistance of battery.

Integration of ups with BMS system.

Upgrade and configuration SNMP (simple network management protocol).

Scanning of ups input and output data.

Experience 3

COMPANY: M/S Khanna Industrial Pipes Pvt Ltd Unit-II Asangaon Thane Maharashtra India

From 6 March 2016 to Jan 2018

POSITION: Sr. Electrical Engineer

Job Profile/Maintenance:

Preventive Maintenance of electrical system in mill plant.

Preventive maintenance of mill plant as per Highly occurrence breakdown.

AC/DC Drive for mill operation and maintenance Allen bradelly, ABB, SIEMENS.

Operation and control H.F dc and inverter panel trouble shooting system.

High voltage (22 KV substation) switch gear panel starting operation and maintenance Supervision and control the maximum demand (M.D) of total power.

Maintenance of L&T air circuit breaker up to 3200 ampere and APFC.

Maintenance of cutting of cart (COC) motor and drives.

Preventive maintenance planning of DC motor, panel, VSD and observation of spare parts.

Breakdown preventive maintenance report and analysis.

Shutdown job man material planning.

Daily energy consumption report and maintain as per maximum demand.

Maintenance E.O.T crane 15 TON, 7.5 TON,5 TON,

Earth resistance measurement of plant as per schedule.

Supervision and maintenance of 2000 KVA transformer and SF6 breaker.

Investigation of APFC Panel in PCC room. if desire power factor (PF) is not obtain. And initiate preventive action procedure.

Experience 4

COMPANY: Hyundai Engineering & Construction Co.

From sep 2013 to July 2014.

Project: M/S MA'ADEN Aluminum Refinery Kingdom

of Saudi Arabia.

POSITION: Electrical Engineer

Job profile/Responsibilities:

Main role: Erection, Pre- commissioning &Testing.

Responsible for complete Electrical works such as (Low Voltage, Medium Voltage & High voltage Switchgear, Lighting, Power etc.) Installation, Testing & Commissioning.

Performed Erection and pre-commissioning 34.5 kv/.48 kv substation, power transformer HV/LV Switchgear & LV MCC Panels testing, supervision of protection relays.MV/LV motor solo run test.

Co-ordinate with vendors and the original equipment manufacturers for all queries regarding, modifications, spare parts, drawings and the resolution of technical problems.

Prepare daily Progress report and submission of weekly reports.

Coordinate with the Safety Officer to ensure safe working conditions and to meet company HSE objectives.

Functional test of LV MCC 480 V, 3200 amps ACB & Switchgear, Incomer and Tie.

Insulation resistance and contact resistance test of bus bar 34.5 KV/14.16 KV/.48 KV Class.

Erection and Installation and supervision of switchgear of 34.5 kv/14.16 kv/.48 kv.

MCC UMC 100 Relay setting as per data provided by vendor ABB

Good understanding of drawing like SLD, Schematic drawing, control drawing etc

HIPOT Test of 34.5 kv bus bar applied voltage 56 kv find out leakage current 65 milliamps same as further.

Contact resistance and insulation resistance test of ACB 3200 Amps.

LV MCC.Inter lock circuit and Inter trip testing between switch board and MCC, and Incomer to tie.

MV/LV Switchgear bus bar insulation measurement and dielectric test, contact resistance. megger, etc.

Functional test of MCC & Switchgear, from HV Switchgear to LV Switchgears.

MCC, Switchgear ACB final setting. Feeder modification according to drawing.

MV/LV Motor functional test, solo run test winding resistance test etc. Experience 5

COMPANY: M/S SCT Limited India. Established Industrial area Meerut road site-3 city Ghaziabad at 1979.A major

Current & Potential Transformer Manufacturing

company Ghaziabad since May 2012 to sep 2013.

POSITION: Electrical Engineer

Client:

ABB Ltd, Siemens Ltd, Crompton Greaves Ltd, L & T. BHEL and Government of India etc. up to 220 KV class substation.

Job profile: testing Department.

All the routine and type test of CT/PT as per IEC & IEEE standard.

testing O.V.I.T, MEGGER, C/TAN DELTA, DVDF, KNEE POINT VOLTAGE,3 KV TEST.

Rating of current transformer we have test done 33 KV,66 KV, 132 KV,220 KV,

Measurement of core size OD, ID & AXIAL LENGTH.

Well versed with high voltage insulation and winding of CT & PT.

Also worked experience in fault finding and repairing of CT & PT.

knowledge of input raw materials quality checking like copper wire, CRGO core, craft paper, Transformer oil, and porcline Insulator.

Experience 6

COMPANY: M/S Lalit Transformer Co.

from July 2010 to Jan 2012.

POSITION: Electrical Engineer

Job Profile :

Finding Number of turns of LT & HT winding (11 KV/440 V).

Delta-star connection of HT & LT winding respectively.

Design of core, axial height and window height and central length.

Designing range 10KVA to 1000 KVA. Distribution transformer 11kv class.

Ratio test, megger test.

final check and inspection before the delivery.

Skills and personal Qualities:

Effective verbal and written communication skills in English, etc.

Good knowledge of basic IT skills and MS Office Application.

Good interpersonal and communication skills.

Ability to work under pressure and manage multiple tasks simultaneously.

Team player, due to the continuous interaction with contractors, personnel and Client's personnel.

Ability to adopt to camp accommodation and harsh meteorological conditions. Technical Qualification: Bachelor of Technology (B. Tech) in Electrical and electronics Engineering from KIET.

Ghaziabad U.P India

Year of passing : 2010

University : Utter Pradesh Technical university Lucknow India. Personal profile:

Father’s Name : Mr. GHULAM HUSAIN

Mother's Name : Ms. Fatima Khatoon

Date of Birth : 05.10.1981

Nationality& Religion : Indian& Islam

Marital status : Married

Language known : English

Passport Details:

Passport no- : T2453879

Date of issue : 16-04-2019

Date of exp : 15-04-2029

Place of Issue : JEDDAH

Declaration: I hereby declare that all the above information is true to the Best of my knowledge and self-belief.

Date & place (MOINUDDIN)

JEDDAH KSA



Contact this candidate