Calvin Yancy
Baytown TX, *****
Cell# 281-***-****
Hood Containers
Houston, Tx. 77091
Operate high pressure steam boiler. Monitor chemical treatment in water. Also fix steam leaks in system.
Rice University 2017 to 2019
4301 Main
Houston,Texas 77005
Provide PMs and monitor several boilers and chillers. Provide chemical test on CT and boilers. Do readings on generators and do monthly generator runs. Make minor repairs on motors and pumps.Change filters belts on AHUs when needed. UTMB 12-1-16 to 6-17
301 University Blvd.
Galveston, TX.
Provided maintenance for UT campus. Including refrigeration, AHU's electrical and PM. Also had to trouble shoot lab equipment. Worked on Hot water domestic pumps and chill water pumps. Preformed word on fan coil units and other related HVAC equipment. Tested water for proper ph balance and other unwanted minerals. HKA 9-13 to 11-16
3333 Hwy.6
Houston, TX.77083
Help with process using hydrogen, nitrogen, steam and ethylene. Also operate 3 boilers And chillers. I do p.m.’s and monitor utilities coming from central plant. Work and operate Cogen boiler.
The Methodist Hospital from 08-12 to 8-13
6515 Fannin
Houston Tx. 77030
Operated 4mw Cogen boiler. Distributing also chill water,steam and electricity. Also monitor Amonia system which filtered carbon monoxide from Cogen boiler. Maintained 7, 2k ton chillers in which 2 were steam driven. Also help with processing of test chemicals for refinery use. Do P.M.’s and lock out tag out, write permits for general maintance.
Johnson Controls from 05-10 to 8-12
3333 Hwy 6
Houston Tx.77083
Monitored 4 mw Cogen boiler along with 1 60kpph and 40kpph boiler, also made sure and maintained air compressor systems and hydrogen and nitrogen systems. Prefrom chemical testing on cooling tower water and hot water loops. Monitored 2800 ton York chillers and associated pumps. Monitored these systems using Allen Bradley monitors. Austin Ind. From 06-09 to 05-10
LaPorte,Tx.
Monitor chemical level on cooling towers and chill water systems. Also p.m. refrigeration equipment. Operated PLC systems for building operations. Maintained boilers for Pilot plant test equipment.
Maximus Coffee Group from 7-07 to 06-09
3900 Harrisburg
Houston, TX. 77003
Operate B & W and N & B steam boilers using Foxboro and Allen-Bradley automated console system.
Monitor and operated 350 thru 500 ton Carrier Chillers; using a 7 cell cooling tower. Preformed water treatment and test on boiler and HVAC systems. Provide Pressure for processing coffee
Provided electrical services to processing equipment including running some conduit and wiring up starters
H-E-B from 5-06 to 7-07
4625 Winfren
Houston, TX. 77041
Preformed maintance on ammonia refrigeration systems Removed repaired and replaced defected components wet condenser systems Provided p.m.’s on equipment as needed
Preformed water analyst on condenser water
Preformed maintance on electrical circuits including trouble-shooting and repairing equipment
Aramark from 2-05 to 5-06
10001 Richmond Ave.
Houston, TX. 77080
Monitored chill water and boiler automated systems Replaced valves and motors on automated ducting systems Replaced steam and chill water valves on coils as needed Performed checks on UPS, generators and other emergency equipment Repaired pneumatic and electrical systems
KBR from 2-03 to 1-05
3120 Buffalo Spdway
Houston, TX. 77098
Repaired vent hood motors for laboratories
Replaced Johnson control valves for A/C systems
Preformed pressurization test on vent hood system
Repaired electrical equipment and also ran some conduit to new construction when called for.
H-E-B from 1-01 to 2-03
10010 Clay
Houston, TX. 77041
Maintained PLC conveyor system
Worked on CIP and other related pasteurization system Monitored high pressure boiler system
Replaced motors and other components as needed
Sugarland Methodist Hospital from 9-09 to 1-01
16655 S.W. Freeway
Sugarland, TX. 77081
Preformed p.m.’s on all hospital equipment
Repaired electrical equipment including beds, electrical plugs and light fixtures Preformed weekly and monthly generator test
Made sure all fire equipment was under code and working properly, also preformed monthly inspections
Monitored chill water and boiler systems
Certification
1st Grade Stationary Engineer Lic. #2417
State Journeyman Electrician Lic. #78582
EPA certified
40 hour Haz-Mat class
Military
U.S. Marines 6-75 to 9-81