Post Job Free

Resume

Sign in

Sr. Technician, Instrument-Electronics-Fire & Gas

Location:
Al Dafna, Qatar
Posted:
November 20, 2023

Contact this candidate

Resume:

REYMOND D. TUMAMBING

Sr. Foreman – Instrument/Fire & Gas

Doha – Qatar +974********

+639********* -Wattsapp

ad1aut@r.postjobfree.com

SUMMARY

Experienced Foreman with more than 16 years of experience in a wide range of Industrial Instrumentation and Control System, Fire & Gas System, Fire Protection System and ELV System. Exceptional experience in operation and maintenance, overall system inspection, installation, construction, pre- commissioning, commissioning, start-up, shutdown in various industry such as Power Plant, Petrochemical, Oil and Gas company and large-scale projects. Excellent reputation for solving problems and improving costumer’s satisfaction. Organized and dependable candidate, successful at managing multiple priorities with a positive attitude. Willingness to take on added responsibilities to meet team goal. WORK HISTORY

Sr. Instrument Foreman- 12/2009 to 06/2020

Qatar Petroleum – Doha Qatar

Duties and Responsibilities

Effectively followed all company rules, guidelines, and HSSE practices and procedures.

Obtained all necessary permit (eCPW, PTW), and conducted Tool Box Talk on daily basis before commencing at work, and coordinates with other departments that may be involve in the job task.

Authorized permit holder and act as a Performing Authority, review documents and validates JSA and Method of Statements submitted by the contractors.

Performed routine checks, inspection, troubleshooting, and calibration of instruments like level, flow, and pressure transmitter, control valves, MOVs, solenoid valves, all types of switches and gauges, in potable water pump skids, sewage water pumping station, and fire water system like level, flow, pressure transmitter, switches, gauges.

Conduct routine maintenance and functional test of equipment and confirm all the signals and action in the PLC panels and in the SCADA system are correct as per design and approve by operation.

Continuous monitoring, control, and operation of BMS System, including calibration of instrument related equipment in the chiller plant and package unit air conditioning. - (YORK Chiller, Petra Package Unit)

Validation and calibration of instrument as per OEM and keep calibration reports.

Conversant to NFPA 72, corporate Fire & Safety philosophy, Guidelines and regulations.

Trained and authorized to perform maintenance, operate, configure and inspection of fire alarm panels (Simplex and Autonica)

Carried out inspection and regular checks of Fire & Gas System, Fire Suppression System, Fire Fighting System in accordance to statutory procedure and company standard.

Performed functional test of fire & gas devices and components on a regular basis to ensure the system are compliant with the regulation. Record all reports in CMMS/SAP.

Supervised the maintenance staff and participated in preventive and corrective maintenance of fire alarm devices including calibration and functional test of smoke detector, heat detector, flammable gas detector, toxic gas detector, HSSD, VESDA, fire suppression system (FM200, Novec, CO2 system) and sprinkles system.

Performed inspection and functional test of fire water pumps, (EATON and FIRETROL) main control panels, fire hydrants, hose reels, sprinklers, and all sensing and instrument connected to the system. Record all maintenance and inspection report in SAP/CMMS.

Responded to emergency call outs, and repair faults immediately.

Properly documented all maintenance reports including PM/CM activities, replacement of parts, calibration reports and update in CMMS/SAP.

Created notification based on the inspection report from the field, convert into work order.

Closed work order in CMMS/SAP and update reports upon completion. Project Scope

Adhere to Company HSE Safety policies, rules and guidelines.

Supervised staff in daily activities and ensured that the work is executed as per plan.

Witnessed site acceptance test and pre-calibration of all instruments before installation.

Conducted inspection of field instrument devices system wise - Fire and Gas, PLC, SCADA, BMS, Potable/Industrial/Sewage Water, Fire Water Pumps, Fire Suppression, and Package Unit Air-Condition System) and verify all installations are in compliance with the project drawings, engineering standards, and specifications.

Verified all inputs and outputs signal is correct as per I/O list and the signals corresponds to the PLC panel and in the SCADA-HMI.

Witnessed and verified instrument system completion activities performed by Contractor including approval of punch list.

Supervised staff and contractors while performing Pre-Start Up Safety Review- (PSSR), Mechanical Completion, pre-commissioning test prior to final commissioning test as per Cause

& Effect Matrices.

Reviewed documents like Method of Statement, Job Safety Analysis, Red line Mark-up, Spare Parts Interchangeability Record, As-Built Drawings, and Project Hand over Dossier.

Carried out project reviews on P&IDs, System limits, Electrical and Instrument drawings

(wiring diagrams, instrument location drawings, instrument loop drawings Achievements

Effectively saved maintenance costs by 30% through optimization; efficient use of consumables, parts and tools, and suggesting multiple process improvements that were implemented successfully.

Repeatedly commended for working in a safe, efficient and accurate manner.

Achieved at least 99.9 % of KPI by completing planned and unplanned maintenance with accuracy and efficiency.

Collaborated with the project team in the development of Ras Laffan Port Expansion Project and Multi-Purpose Administrative Complex

Promoted from Technician to Sr. Instrument Foreman Instrument Technician – 02/2008 to 12/2008

Petro-Rabigh Project and Al Waha Petrochemicals

Tecnimont ICB Pvt. Ltd – Saudi Arabia

Strictly followed Health, Safety, Security and Environment (HSSE) practice and procedures.

Performed Logic/Interlock/Sequence test of instrument with the vendors and clients.

Verified and validate I/O list and confirm all signals from field instrument is corresponds to the faceplate individually in the DCS.

Assigned in calibration of process instrument such as pneumatic and electronic transmitters, gauges, solenoid valves, control valves and switches.

Performed loop checking of process instruments, control valves, Start/Stop of Motors, compressors and pumps.

With exposure in YOKOGAWA CS CENTUM 3000 R3 DCS and Yokogawa instrument. Instrument Technician - 07/2006 to 03/2007

Global Professional Services W.L.L.-Qatar

Performed trouble shooting, repair, preventative, predictive and corrective maintenance.

Calibration of smoke detector, combustible gas detector, H2S detector, simulation of heat detector and UV/IR flame detector and Manual alarm call point.

Performed commissioning activities in regards to fire and gas systems, such as smoke detectors, gas detectors, fire alarm control panel.

Participated in calibration, upgrade of field instrument during QAPCO shut-down. Instrument Technician - 03/2003 to 09/2004

Hadi Hammad Al Hammam Establishment – Saudi Arabia

Assigned in the calibration of process instrument including pneumatic and electronics transmitter, and pressure gauges in the furnace and Crude Distillation Unit (CDU) – Aramco Rabigh Refinery.

Routine and preventive maintenance of instrument and electrical related job in Aramco Jet Fuel Operation at King Khalid International Airport – Riyadh KSA

Aramco Authorized permit receiver (PTW)

Instrument Technician - 11/2001 to 03/2003

I&E Industrial System Services Inc. – Philippines

Monthly on-site and off-site calibration and validation of process instruments @ First Gas Power- Siemens Power Operation Inc.- 1000 Megawatts Power Plant Project, Sta. Rita Batangas City SKILLS and EXPERTISE

• Safety Awareness

• Leadership

• Teamwork

• Collaboration

• Supervisory Skills

• Interpersonal and Communication Skills

• Troubleshooting

• Instrument Calibration

• Field Instrumentation

• Technical Documentation

• Direct Digital Controller

• SAP Plant Maintenance

• Fire & Gas Systems

• Emergency Shutdown System

• Yokogawa, Rosemount, Siemens, Foxboro Instrument

• Detronics, Multi Spectrum IR Flame Detector, Dragger

• Microsoft Excel, Word, Power Point

• Familiarity with smart devices in the oil and gas industry

• Use of test and calibration equipment for most transmitters and other industrial devices in the field. (e.g. multimeters, pressure calibrators, communicators).

• Familiarity with P&ID and instrumentation and control symbols (ISA standard)

• Understanding of basic process control in PLC and DCS operation.

• Hydrogen Sulfide Awareness (H2s)

• Permit to Work (PTW, eCPW)

• TBOSEIT and HUET

EDUCATION

Batangas State University - 2001

Bachelor of Industrial Technology

Electronics Engineering Technology

Industrial Instrumentation Course - 2001

TESDA Region 4A, Batangas City, Philippines

TRAINING ATTENDED and CERTIFICATION

Tropical Basic Offshore Safety Induction and Emergency Training – Enertech Qatar

YORK YK Centrifugal Chiller and Variable Speed Drive –Johnson Controls

Building Management System (BMS) – Johnson Controls

YORK YCIV Screw Chiller Operation and Maintenance –Johnson Controls

SI and IQMK2 Range Actuator – ROTORK Qatar

Introduction, Operation and Maintenance on Endress + Hauser - Qatar

SCADAvantage Operator – ABB Qatar

SCADAvantge Basic Administrator – ABB Qatar

CIMAC PLC System training – Schneider Electric

Tricon/Tristation Fundamentals – Invensys Middle East

Building Automation & Energy Management System Operator – Siemens Qatar

Building Automation & Energy Management System Administrator – Siemens Qatar

Autronica Autrosafe Interactive Fire Detection System – Autronica Norway

Autronica Autrosafe Configuration and Programming Course – Autronica Norway

CRP and EAD First Aid – Qatar Petroleum

Basic Firefighting – Qatar Petroleum Fire Department

Confined Space Entry Procedures – Qatar Petroleum Safety Department

Safety Induction Training – Qatar Petroleum

CHARACTER REFERENCE

Ibrahim Shalabieh Ibrahim

Lead Instrument and Communication Engineer (QE)

+974-****-****

ad1aut@r.postjobfree.com

Bassam Assad Al Brihi

Sr. Instrument Engineer (QE)

+974-****-****

ad1aut@r.postjobfree.com



Contact this candidate