Resume of

MICHAEL D. RILEY

** ******* **.

Fairmont, West Virginia 26554

304-***-**** cell

EMAIL: ad11hz@r.postjobfree.com

OBJECTIVE

To obtain a career as a Project Manager or Plant Manager or other related position with a recognized leader of power generation.

Experience Summary

More than 20 years of general engineering experience in the power generation field including H.V Substation construction and commissioning.

Experienced in equipment troubleshooting and root cause analysis.

More than 18 years of supervisory experience, including Maintenance, Operation, and Engineering management.

Working knowledge of Excel, Word, Windows, and computer hardware.

Successful experience in Union organizing campaigns, planning campaign tactics, literature, and crew meetings.

Utility and I.P.P. experience with cost control, budget planning and personnel contacts.

Responsible for the Operation and Maintenance of an 80 Megawatt fluidized bed boiler power plant.

Implemented a Heat Rate improvement program at Ft. Martin Power Plant which was rated the fifth best in 1989 by E.L.& P. magazine.

Experienced with contract administrations of the Electrical Energy Purchase Agreement. Including, working with the Law firm of Dewey Ballantine on the Grant Town Arbitration Case against Allegheny Power to improve profitability.

Management Philosophy

Expect Quality material, equipment, and service.

Expect results from all personnel and contractors.

Hold individuals responsible for their actions and performance and reward when required.

Take the time to find the right employee.

Education

West Virginia University, Morgantown, WV

Major: B.S. Electrical Engineering September 1970-May 1975 Vibration Analysis Seminar September 1976

B & W Boiler Performance Seminar September 1983

C. E. Boiler Performance Seminar May 1985

General Physics: Performance

Testing for Utility Engineers May 1988

Labor Relations Seminar September 1988

Bailey Controls

Net90 Control Applications May 1989

General Electric: Turbine December 1989

Performance Seminar

Bentley Nevada Advance Vibration

Analysis Seminar August 1990

Pyro Power Boiler Operations July 1992

Training Seminar

Zenger Miller:

Business Skill Team Building Seminar June 1993

Timeline Project Management

Seminar January 1994

2

Minnesota Management Academy March 1997

ASM Failure analysis seminar August 1998

Refrigeration-Universal License May 2012

U.S. Army Corps of Engineers

Construction Quality Management May 2018

Professional Experience

Actalent:

Schneider Electric-Data center project LVL08 Jan. 2023 to Present

Superintendent for Schneider Electric at The Boydton, Va Data center site. Working on a Hot Air containment system for 20 Mechanical Electrical Rooms. Supervising electricians in completing the task to allow the temperature to not exceed 104 degree F to the UPS cabinets.

REV1

Constellation New Energy -Micro Grid project Nov.2020 to Sept.2032

Responsible for Project Management and Quality Control of design, material and construction processes for the installation of Micro grid controls from eight I.C. Engines, BAS load shedding, and 8.5 Mw Steam Turbine Generator. Testing and operation of Micro Grid with M&V annual acceptance from Marine Base and NAVFAC. This is a combined ESPC project with a total reduction in energy consumption associated with controlling the Base total power from the installed STG and I.C. Engines. This is the most advance Micro Grid on a military base in the world. Included with the design is 11 RTU units with a data warehouse connecting to a 130 building BAS server and RTU server to automatically control all power related issues. Medium voltage substation commissioning and construction

Work Management, Inc.

Constellation New Energy MCLB Projects

3

Quality Control Manager/Project Manager July 2018 to Oct. 2020

Responsible for Project Management and quality control of design, material and construction processes for the installation of lighting re-lamping, Micro grid controls, air compressor changes, steam turbine installation with a three mile transmission system and building automation of 120 building at the Albany Marine Corp

Logistic Base.

Electrical Manager Aug. 2017 to July 2018

Responsible in verifying installation of design for the electrical equipment of Marine Corp micro grid; Land Fill gas generator 2.1 Mwe and 8.5 Mwe steam turbine and controls project in Albany, Georgia.

Duties include review and approval of design for the 8.5 Mwe turbine and generator as well as the SCADA system for the micro grid to obtain Net Zero for the Marine Corp Logistic Base. Make recommendation to design including modification required to meet UFC and UFGS specification.

Review engineering drawing and specifications to verify proper installation of electrical design.

Assisting in start-up and commissioning activities to provide oversight for safety and proper operation of equipment. Responsible in verifying design and installation of the MCLB micro grid controls with Schneider Electric for load shedding and data storage.

Work Management Inc.

Albany Green Energy Project

Electrical Manager Oct. 2016 to July 2017

Responsible for the Quality control and Quality assurance of installation of the design of the electrical equipment and controls for a 50 Mwe to Georgia Power and CHP steam to Procter and Gamble. Duties include writing reports daily on progress to Project Manager. Report to Exelon Engineering on design changes and modifications.

Reviewing engineering drawing and specifications to verify proper installation of electrical design.

Assisting in startup and commissioning activities to provide oversight for safety and proper operation of equipment. The project is a waste wood fuel to steam energy supplying electricity to Georgia Power and steam to P&G.

4

Rino Partners,LLC

Marion County Project

Development Engineer Sept. 2012 to Aug. 2015

Responsible for the development of financial model and development of gas contracts and equipment specifications for proposed combined cycle gas turbine project.

Preparing development and operating budget estimates for combine cycle gas turbine projects.

Prepare power point presentation for potential investors, which includes presenting to assist in development capital for several projects in the tri-state area.

Mission Operation and Maintenance, Inc.

Plant Manager - Grant Town Power Plant Feb.2006 to Aug. 2008 Presently manager of 54 employees with 10 supervisors. Presently developing 10 years O&M plans with new environmental rule to be competitive in the next 27 years remaining on the power purchase contract with Allegheny Power.

Plant Manager - Goat Mountain Wind Farm Feb. 2008 to Aug. 2008 Managing a 100 Turbine windfarm consisting of 1MW and 2.4MW Mitsubishi Wind turbines. Located in Robert Lee, Texas. and supplying LCRA with 345KV transmission voltage, completed construction and commissioning with approval of LCRA H.V. Transmission Group out of Dallas, Tx..

Start-UP – February 2008 and presently generating test power to the grid. This is a merchant facility and will be controlled by SCADA from Boston, Mass.

GRANT TOWN FACILITY Nov. 1991 to Aug. 2008

Operation Supervisor

Responsible for Startup and training for the Operation Department personnel at Grant Town - a state of the art fluidized bed boiler with a total of 28 operators including 5 Shift Supervisors.

Responsible for the Instrumentation and Electrical Department during construction, startup, and operations of the facility with 7 personnel.

During two separate occasions performed as the acting Plant Manager for two months in 1993.

5

Responsible for development of the Grant Town Operation and Maintenance Manual, Standard Operating Procedures, Startup & Check out procedures, and personnel policies.

Operation And Maintenance Supervisor Feb. 1995 to 2006 Presently manager of 42 employees with 7 supervisors. Continue make plant modifications to improve plant performance and reduce operating cost.

Project Manager for the following major projects:

A. Generator rewind and rotor fan hub re-design

B. Primary Air heater replacement.

C. Reduction for limestone consumption to below design requiring velocity change to boiler cyclones.

D. Annual planned maintenance outages.

E. Cyclone vortex replacements.

F. Modifications to the fuel prep facility from a wet processing system to a dry system.

Presently responsible for all operational and maintenance activities at the Grant Town Facility for Mission Operation and Maintenance.

G. Expert witness for American Bituminous Power Partners during arbitration with Allegheny Power to resolve contract dispute.

MONONGAHELA POWER COMPANY

RIVESVILLE POWER STATION

Plant Engineer May 1978 - May 1980

Start up engineer of coal sampling auger system.

Designed and assisted installation of environmental control and monitoring equipment.

Plant Representative for Monongahela Power with Poe, Evans

& Roberts Company during the testing of the Fluidized Bed Boiler at the Rivesville Power Station.

MONONGAHELA POWER COMPANY

FT. MARTIN POWER STATION

ELECTRICAL MAINTENANCE SUPERVISOR May 1980 -March 1982 Responsible for entire plant electrical maintenance from switchgear (600 v to 500kv ) to motor repair and balancing of 6,000 H.P.- 11.5 kv to 10 H.P.- 600 v.and burner management and generator excitation systems.

RESULTS SUPERINTENDENT March 1982 - Nov. 1991

Responsible for maintaining plant efficiency and

reliability.

6

Supervise the activities of one foreman, two Electrical Engineers, one chemist, one water technician

Assisted in design, installation, and start-up of plant a new Net 90 DCS Control System retrofit in 1988.

Responsible for environmental and hazardous waste limits. Responsible for hiring/training chemists, engineers, and technicians.

Develop and implement Results Department safety rules. Assist both the Operational/Maintenance Departments with modification changes in pumps, fans and other power generation related equipment.

Responsible for the plant's data acquisition system which helped maintain Allegheny Power as one of the top 15 utilities companies in overall plant heat rate within the nation. BABCOCK and WILCOX NUCLEAR

MATERIALS DIVISION - APOLLO, PA

Associate Design Engineer May 1977-May 1978

Design of total gas release lab cooling system.

Design and start-up of criticality and fire alarm system for the process plant.

VIRGINIA ELECTRIC POWER Co.

MT. STORM POWER STATION

Assistant Results Engineer May 1975-May 1977

Testing and calculating turbine efficiency, boiler efficiency, and overall plant efficiency. Vibration Engineer, responsible in balancing a rotating equipment. Troubleshooting various plant equipment as: turbine M.H.C. controls, Boiler systems, Burner management systems, and switch gear equipment.

.

Consulting:

Councils of Advisor:

Temporary consulting for Power plant and related industries. 1 Project Development with Wellington Development

Developed a O&M Performa and capital proforma for the Greene Tri-State Refractory:

7

Provide consulting service for solid fuel power plant for maintenance and operation solutions.

OTHER QUALIFICATIONS

Computer proficiency consist of DOS, Excel, Word, 123 Lotus, Timeline, PMC ( computer maintenance management system) and Mainsaver.

Experienced and assisted in five successful anti-union campaigns against the I.B.E.W and U.M.W.A. Responsibilities included preparing literature and conduct crew meeting during these campaigns with a national Law firm.

REFERENCES: Furnished upon request.

SALARY: Furnished upon request.

8