RESUME
Mr. AMAN KUMAR CHOUDHARY
Address:
Om shanti nager plot no-30, behind deshpande petrol pump
(anandwan chowk). Po-chinora, th-warora
Dist-chandrapur, maharashtra, pin no-442914 Mobile-084********, E-mail- aczg7l@r.postjobfree.com
MECHANICAL ENGINEER
•Beaked with +4.10 years of total work experience.
•Experience n of thermal power plant of (4x135 MW) as a Asst. field engineer (in operation department).
Having an experience in operation engineer, and also worked in Manufacturing Company.
CAREER OBJECTIVE:
To excel in the field of power sector and to be a part of the growth oriented team where I can use my knowledge and experience to achieve organizational goal effectively as well as personal growth
PREVIOUS EMPLOYER:
•Company- MSRTC (MAHARASHTRA STATE ROAD TRANSPOARTION CORPORATION) CHANDRAPUR DIVISION.
Location- Chandrapur, Maharashtra.
Work profile- Maintenance.
Designation- Jr. Engineer
Duration- sept-2007 to Oct 2008 ( 1 year APPRANTICSHIP)
.
CURRENT EMPLOYER:
•Company- KEPCO plant services & engineering co.ltd. (Korean Power services) O&M
•Client- Wardha Power Company Ltd. [Unit of KSK Energy Ventures Ltd]
•Location- At Worora growth centre, Worora. Dist -Chandrapur, Maharashtra.
•Designation- Asst. Engineer (Field operation)
•Functional area- Turbine, Boiler, coal Mill, FOPH, CWP, DM plant, RO plant, Fire fighting.
•Duration- March 2011- jan 2015 (3.10 years experience )
•Company profile - 540 MW Thermal power plant having 4x135 MW Turbine and 440 TPH x 4 PF Boiler. (BTG- Chinese)
Boiler details:
•440 TPH PF Boiler, 14.29 Mpa, 540/540’C reheat natural circulation, Balanced ventilation, Solid slag, medium speed mill & two tri-section air preheater, Coal corner- fired drum type boiler.
•Make- Dong fang (DG440/14.29-II10)
JOB RESPONSIBLITIES:
•Responsible for overall functioning of boiler including light-up & shut down.
•Regular monitoring of the equipment like Coal mill, Coal feeder, APH, FD, ID, PA, seal air & scanner fans.
•Responsible for normalization & isolation of all equipment.
•Handling emergencies like black-out in boiler & Coal mill area.
•Regular inspection for smooth running of Equipments, ensure smooth and safe operation..
•Responsible for operation of auxiliary boiler of 15 kg/cm2
•Maintaining daily log book, shift report & defect book.
•Check normal operational parameter & fill the check list accordingly.
•Check for the leakages.( oil, coal, air, flue gas, water, steam & ash)
•Co-ordination with Maintenance Department (Mech., C&I & Elect.)
Regular communication with control room via Walkie-Talkie.
WORKING EXPERIENCE:
•FIRE FIGHTING PUMP HOUSE
Diesel spray pump, Electric spray pump, jockey spray pump, hydrant pump, diesel spray pump.
•CWP (Circulating water pump house)
CWP, hydraulic unit, hider distribution, recirculation pump, CT-fan,riser MOV,c t fan gear box, screen motor, ash compressor return line, fiber filter, service makeup, blow down, make up ETP plant.
•FOPH (Fuel oil pump house) & auxiliary boiler
HFO tank 750kl, LDO tank 200kl, HFO supply pump, LDO supply pump, HFO & LDO U/L pump, LDO pump HFO heater, heater MOV, long short recirculation, control valve, oil water separator. HFO & LDO tank changeover, HFO heater changeover.
Auxiliary boiler 7.53MW:
(starting sequence from starting operating operation to hot box up), feed water pump, LDO supply pump, gauge glass, centrifugal fan.
•ESP (Electrostatic precipitator)
Field transformer, CERM, EERM, bag filter, ID fan, dust collector.
•Coal mill -Local line up and isolation of equipment such as ID,FD PA,SA fans
( pulverize rated capacity 26.21 tons/hr), raw coal feeder 5 to 52 tons/hr, PA fan(37m3/hr,pr-12000pa/sec), Seal air fan, FD fan(68m3/hr,pr-3065pa/sec), ID fan(137m3/hr,pr-4830pa/sec), hydraulic unit.
Boiler: (PF top support, single re-heater, single drum, water tube boiler).
•steam generation capacity-440 t/hr,heating area-13200m3,pressure-150 bar, shoot blower pressure-1.3 MPa, shoot blower-(IR,IK,IKEL,APH). scanner fan,APH, gauge glass, hydra step, vent station,drain station,HFO & LDO station,HFO&LDO gun, safety valve, PCV, mssv. Monitoring and reporting the LDO and HFO oil pr and system leakages from line or at boiler Firing Flore and near gun. manual operation of valves in drain lines and in different system in boiler area as directed by boiler engineer. Coordination with control room during shoot blowing and manual retraction of wall blower. Boiler light up, elevations (wind box, HFO burners, flame scanners, HFO, LDO gun.). Air pre-heater. Soot blower, purging, boiler drum. APH, Scanner fan. Monitoring of parameters like oil pressure,oil level, local gauge. Bearing temperatures of all above fans.
•Monitoring furnace flame for healthiness and boiler internal shoot deposition monitoring and reporting. bottom ash hopper unloading and area cleanliness. Co-ordination with control room while cut in HFO and LDO gun, and isolation, normalization during oil gun cleaning. LRSB .monitoring and reporting the scanner fans, APH motor running status, oil levels and bearing temp and ash/air leakages from APH. Checking for safety valves passing and S/RH spray line leakages. Cleaning of equipment’s and its instruments, electrical equipment and local panels and maintaining area housekeeping.
•Turbine –BFP., CEP, Vacuum pump, acw pump.
JOB RESPONSIBLITIES:
•Daily, Weekly & Monthly planning of work.
•Daily reporting to deputy Engineer.
•Daily reporting to maintenance team.
•Ensure safety & health of workers.
•Maintaining attendance of workers.
•Maintaining store materials.
•Ensure optimum utilization of resources.
•Handle 50 Workers including 2 Supervisors.
•Co-ordination with the local people.
•Company- ECONOMICS EXPLOSIVE PVT LTD.
Location- Village-shivanga, fun & food NAGPUR, Maharashtra.
Work profile- Production supervisor.
Designation - Supervisor
Duration- July -2009- Jan- 2011
JOB RESPONSIBLITIES:
•Check production on hourly basis.
•Check quality parameters of processed material as per the inspection sheet provided by the client.
•Material allotment to workers for processing.
•Quality and quantity inspection.
•Ensure Packing & Dispatch of consignment with proper material tag.
•Ensure safe operation.
•Tool used (Micro-meter & Vernier Caliper)
•Check inward material as per challan.
EDUCATIONAL QUALIFICATION:
•Bachelor of MECHANICAL ENGINEERING(BE) from Nagpur University, in the year 2011.
•Diploma in mechanical engineering from Maharashtra state board technical education. in the year 2007
•SSC from BSSB Patna, in the year 2002
COMPUTER SKILLS:
•MS-CIT
•MS- Office
•
ACADEMIC PROJECT:
•Engineering project (Final year): CAV (compressed air vehicle)
•Engineering project (2nd year): JHOMENY QUENCH.
•Diploma project(final year): setting the kerosene limit in petrol.
EXTRA CURRICULAR ACTIVITES:
•Renewable Energy sources 3D CAD, Rapid prototyping and rapid manufacturing.
•Characterization of material.
•National power training institute (NPTI), Western region, Nagpur, An ISO 9001: 2000& 14001 organizations (Under the ministry of power govt of India).
STRENGTHS:
•Self-confidence.
•Hardworking & Positive Attitude.
PERSONEL DETAILS:
Name : Mr. Aman kumar choudhary
Father’s name : Mr. Sachidanand choudhary
Date of birth : 21th march1986
Marital status : Married
Languages known : English, Hindi (Read, Write, Speak)
Hobbies : Writing thoughts, Music etc.
Nationality : Indian
Declaration:
I hereby declare that all the information furnished above is true to the best of my knowledge.
Date : 25/03/2017
Place : Delhi ( samalka ) Signature :