Post Job Free

Resume

Sign in

Maintenace, Commissioning, & Start-Up Instrument Technician

Location:
Navsari, GJ, 396424, India
Posted:
March 05, 2017

Contact this candidate

Resume:

Curriculum Vitae

Post Applied for : Instrument Technician

Name : Bhavesh Kumar Suman Bhai Mistry

Permanent Address : 75, Ramngar Society,

Kabilpore, Greed road

Navasari, Gujarat. INDIA Pin: 396424.

Current Location : India

Telephone No : GSM No: +91-955*******

Present Contact No : +91-903*******.

E-Mail Id / Skype ID : acy4mb@r.postjobfree.com / kumarbhai43

Date of Birth : 13/01/1983.

Passport Details : K-7671857

Date of Issue : 13/02/2013 Date of Expiry : 12/02/2023

Place of Issue : Surat

Material Status : Married

Educational Qualification : SSC in March 1998.

Technical Qualification:

(1) Diploma in Dec. 2006 in Instrumentation & Control Engineer

(2) Gujarat Technical Institute in July 2000 in Instrument Mechanic Trade.

(3) Training Govt. Of Gujarat Instrumentation Technician

Career Summary: Over 12 years plus experience in Instrumentation and Control on major projects in Oil filed projects, Petrochemical, Chemical plant Gas plant. My Comprehensive experience includes online Corrective & Preventive maintenance, plant construction, Commissioning & Start-up assistance & Shut Down job. Capable of doing Calibration & repairs of various pneumatic and electronic field Instruments & Loop checks & Function test on Honeywell PKS C300,Honeywell TDC3000,Honeywell TPS System, DETA V( SCADA), Yokogawa Centum CS 1000 DCS & Bentley Nevada System. Able to read all applicable drawings including P&I, Loop Sheets, Cable schedule, JB wiring Instrument Location & Instrument Hookup drawings, Instrument data sheets.

Specialties : Modbus Check, RFI, Loop Check, Function Check, Start-up, Commissioning, Installation, Troubleshooting, Calibration, Repairing, Operation & Maintenance of Instrument & Shut-Down job

HANDLING OF TEST EQUIPMENT & INSTRUMENTS

Knowledge in handling the test equipment like Druck calibrator, RTD calibrator, thermocouple calibrator Dead weight tester, fluke multimeter, Hart communicator of fisher Rosemount (model 275, 375,475), FOXBORO with HHT, Honey well with SFC etc.

Experience in Brief:

1) Employer : SPIE OIL& GAS MIDDLE EAST SERVICES (Doha- Qatar)

Client : Qatar Petroleum

Designation : Senior Instrument Technician

From : 12/03/2015 to 22/03/2016

JOB RESPONSIBLITIES:

Performed Preventive & Corrective And Emergency maintenance including calibration, Fault finding and Trouble shooting Of instrument and daily routine jobs with DCS System.

Performed calibration of preventive maintenance instrument and preparing certificate

On system and uploading to SAP

Conducts Monitoring and maintenance of field instruments based on schedule

Calibrates transmitter: PT,TT LT & FT, (Rosemount, Honeywell, Yokogawa, Endress &Hauser),

Calibration and configuration of control valves with a Digital Valve Controller(DVC) of Fisher Samson, Parker & Measoline, On-Off Valve & Mov Calibration Function Test & Troubleshooting

Maintenance and troubleshooting of different types of instrument

Support operation for shutdown activities

Loop checking of instruments based on prepared loop drawings from field going to the central control room

Commissioning and functional testing of instruments

Hot and cold loop checks and functional test of field instruments and signals to central control room (CCR) via hard wiring and serial link.

Receive for permit to work & Ensures safety in the work place

2) Employer : SPIE OIL& GAS MIDDLE EAST SERVICES (Leighton Offshore - Iraq)

Client : South Oil Company (Iraq)

Designation : Senior Instrument Technician

From : 25/07/2013 to 16/11/2014

JOB RESPONSIBLITIES:

From console station all parameters maintain as per operation and controlling the process value

Monitoring and controlling to process, operation and maintenance from systems to field trouble shoot and solve the cause.

Check control systems check all configurations and parameters through marshaling cabinet

Performed and performance check all types of sensor like temperature, speed detector, chip detector, vibration probe axial and redial. For trouble shoot and solve with HSE rules and regulation. And supported to operation team involved in production.

Preparation of project work, QA/QC documentation, coordination, monitoring & Control site QA/QC Activities including stag wise inspection at project site all require certificates.

Calibration (lab & field),Loop check, Function testing,& Commissioning of Transmitters, Indicator, Controller, Control Valve, Switches and all Instrument related oil plant.

All plant instrument record and calibration certificate updated by SAP systems and planning next due date for the calibration as per calibration procedure. Commissioning and functional testing of instruments

Maintenance and troubleshooting of different types of instrument

Receiver for permit to work & Ensures safety in the work place

Support operation for shutdown activities

3) Employer : PRINCE ENGINEERING

Client : Gujarat Gas Company

Designation : Senior Instrument Technician (Maintenance)

From : 02/06/2012 to 15/07/2013

JOB RESPONSIBLITIES:

Co- operation with operation, preparing equipment for maintenance & returning to safe service.

Good experience in case study of plant & modification implementation to avoid failure repetition.

Field modification, Fault Diagnosis & Trouble shooting.

Day to Day Activities ( job Distribution, Safety talk, Tool box Talk, Permit Authorization etc.)Central Control Room.

Involved in day to day preventive Maintenance for field instrument, individually and in a team.

Shift duties as a shift in charge Instrument for Instrumentation maintenance & Troubleshooting.

Well experienced in all type of electronic instruments calibration, commissioning, servicing.

Experienced in various troubles shooting to Pressure transmitter, D.P.T Flow transmitters, Temperature transmitter, Level transmitter, Control valve, Switches and etc.

Repair and overhauling of Control valves and positioner calibration and stock check.

Smart transmitters calibration and maintenance work.

Loop checking & commissioning of all kind of field Instruments. Involved in continuity checking, simulation & pre commissioning activity. Trouble shooting of new loop and Modification of internal panel wiring.

4) Employer : BHAWAN ENGINEERING COMPANY (SHUT-DOWN JOB - OMAN)

Client : Oman Indian Fertilizer Company

Designation : Instrument Technician

From : 09/04/2012 to 06/05/2012.

JOB RESPONSIBLITIES:

I had worked in OMFCO. Had attend their shut down of Ammonia plant. I had done calibration of control valves with SMATR positioned SVI & SVI 2, Press Transmitters, flow transmitter, level- trolls and I also removed and reinstallation of thermo wells and also calibration Temp transmitters.

5) Employer : BHAWAN ENGINEERING COMPANY (SHUT- DOWN JOB - OMAN)

Client : Shohar International Urea & Chemical Industry

Designation : Instrument Technician

From : 07/01/2012 to 08/02/2012.

JOB RESPONSIBLITIES:

I had attended their shut down of TRAIN # 1&2& BOILER # 1&2 & Compressor Area. I had attended their calibration of control valves on-off valve, various type of transmitter& switches. Start up activities.

6) Employer : SAIPEM ENGINEERING (DOHA –QATAR)

Client : Qafco Project

Designation : Senior Instrument Commissioning Technician

From : Oct. 2010 to Oct. 2011.

JOB RESPONSIBLITIES:

Working as Group Leader For Loop Testing, Functional Test, Pre Commissioning, and Commissioning Activities Of Various Instruments Related to Process, Utilities & Offsite. Also Involve in Maintenance Job during the Warranty.

Mainly involve in calibration, loop checking, Pre commissioning and commissioning activities: loop check, trouble shooting, calibration, and function check, start up activities of GE Compressors with GE Gas turbines (Frame 6 and Frame 7), boil off Gas Compressors,Train1 general instruments (Fieldbus and Hart ).Worked on Vibration System ( Bentley Nevada Series #3500). Also involve in operation maintenance with RFO Team.

Preparing the report on punch list for any problem/abnormality encountered on the device/instrument on actual field & correction for wiring termination in the junction box cabinet & instrument technical room (ITR).

Testing, calibration and maintenance during pre start-up of the system on the temperature, pressure, flow & level transmitter instrument/device using hart 375/475 communicator.

Hot and cold loop checks and functional test of field instruments and signals to central control room (CCR) via hard wiring and serial link.

Test simulation of the control valve percentage of opening & closing.

Doing as build on the instrument loop diagram & mark up for any changes or discrepancies.

Verification of the ESD trip on the control panel

7) Employer : LINDE ENGINEERING & C.C.I.C. (U A E)

Client : Brouge Ethylene (EU-2) Project & Gasco

Designation : Senior Instrument Commissioning Technician

Duration : July 2009 to July 2010

JOB RESPONSIBLITIES:

Inspection and confirmation of instrument loop line as per loop diagram and inspection of instrument location as per the latest revision drawing.

Commissioning of all instruments in process and utility area such as flow, level, pressure, differential pressure, temperature transmitter testing and adjusting the gap voltage Vibration, speed, trust sensor Bentley Nevada 3500 series Stroking and Calibration troubleshooting of Fisher ControlValve.

Commissioning GAS TURBINE GENERATOR MARK VI PANEL. Asst. vendor of G.E, loop checking and calibration function testing GT.Testing of Process Control Valves, On-Off Valves, Emergency Shutdown Valves and its system configuration.

Field simulation for graphic checked in Central Control Room and to ensure the proper orientation of instruments & motors and correct address to the Input/ Output card/ module.

Trouble shooting in DCS & PLC.

Logic checkup from field to DCS & PLC, and field instrument calibration.

Checking & calibration for control valve, safety valve, plant startup activities in process area.

8) Employer : SAMSUNG ENGINEERING (SAUDI ARABIA)

Client : Tasnee Petrochemical Ethylene Cracker Project

Designation : Instrument Technician

Duration : March 2007 to March 2009

JOB RESPONSIBLITIES:

Performed corrective & preventive and emergency maintenance, trouble shooting, repairing Of instrument and daily routine jobs

Performed calibration of preventive maintenance instrument and preparing certificate

On system and uploading to SAP

Checking the spare availability on SAP for shut down job

Having good knowledge in servicing and calibration of smart instrument devices with Hart Compatibility on line and offline servicing, calibration of pneumatic, hydraulic, motor op-erated valves and accessories (Positioners (smart). Booster rely, lock up relay, transfer valves and position transmitters).

Performed calibration, configuration and trouble shooting of transmitter such as ROSEMOUNT, ABB AND YOKOGAWA .

Worked with foundation and fieldbus and hart protocol transmitter and positioners

Closing the work orders for completed jobs.

Maintain all Documents/ Records of Preventive maintenance, SOP, Calibration Certificates & other documents required for various Audits (ISO)

9) Employer : NAVIN FLORINE COMPANY

Client : Navin Florine Co. (Surat)

Designation : Instrument Technician (Maintenance)

Duration : 12/08/2004 to 25/02/2007

JOB RESPONSIBLITIES:

My responsibilities are to make permit and arrangement for all technicians as will as for all zero checking, calibration, valve overhauling, material inspection, pressure testing, loop checking, removal & fixing of different types of Instruments & Provides all requirement to make job easy and in time and to satisfy our clients and to complete all jobs and to maintain all documents for clam.

To make all arrangements to do pre- commissioning for the new DCS controlled system and its associated process loops and installation and commissioning of process instrument. My special skill to make any task in time.

I was engaged in erection, commissioning, start up and modification of different loops and instrument as per process requirement.

10) Employer : GUJARAT GAS COMPANY

Client : Gujarat Gas Co. (Surat)

Designation : Instrument Technician

Duration : 01/01/2003 to 26/04/2004

JOB RESPONSIBLITIES:

Installation of instruments, cable termination and loop checking, commissioning calibration, and troubleshooting for all kinds of loops

Lab calibration of Various electronic & Pneumatic field and panel instruments

Walk down on all sub-system and updating all the drawings on actual field installation base on the piping & instrument diagram (P&ID).

Testing, calibration and maintenance during pre start-up of the system on the temperature, pressure, flow, level transmitter on/of valves & control valves instrument/device using hart 375/475 communicator.

Hot and cold loop checks and functional test of field instruments and signals to central control room (CCR) via hard wiring and serial link.

Correction of wiring termination in the junction box cabinet & instrument technical room (ITR).

11) Employer : ATUL CHEMICAL LTD

Client : Atul Chemical Ltd.

Designation : Instrument Technician (Apprenticeship)

Duration : 14/04/2001 to 13/04/2002

JOB RESPONSIBLITIES:

Association work with preventive and corrective maintenance overhauling and shut down job. I had done overhauling of controlvalve & all instruments calibrated fire alarm systems and related logics. Calibrated and tested smoke detection systems, flare system. I had done interlock checking ESD checking and shut down. Well experienced in all types of electronic instrument calibration, commissioning and servicing. Experienced in various troubles shooting to pressure transmitters, D.P.T. Flow transmitters, temperature transmitters, R.T.D. I/P converters, level trolls and etc.

TRAINING & SEMINARS :

Permit To Work Course

Safety Induction.

First AID Training

Confined Space Training Course.

Training H2S & Breathing Apparatus course

COMMISSIONING ACTIVITES:

Handled start up & commissioning activities mainly DCS simulations & monitoring for loop checks, panel checking, field instruments commissioning & loop checks. Its calibration & also trouble shouting during commissioning test runs & start up co-ordination.

CONSTRUCTION ACTIVITES: Handled impulse lines according to hook- ups. Instrument air headers, cable trying, Terminal tray work, J.B. instruments installation & control room panel

I CAN READ:

P & I Diagrams, ladder logic, plant instruments location & wiring diagrams, signal cable diagrams, earthling system details & loop diagrams

FIELD INSTRUMENTS HANDLED :

1) Temp & Pressure Measurement: Fisher Rosemount, Foxboro, Yokogawa, Honeywell smart field transmitters, various T/C, RTD

2) Level & Flow Measurement: Ultrasonic & Capacitance Level Transmitters (Endress & Hauser, Danfoss), Displacer Leveltrols (Fisher, Masoneilin), Vortex meters, Magnetic flow meter (Krohne, Endress & Hauser), Flow Transmitters (Fisher Rosemount, Yokogawa, Honeywell).

4)Valves : Fisher, Masoneilin control valves; Antisurge control valves (Fisher CCI drag), Motorized Operated Valves (Biffi, Rotork), Ball Valve, Angle Valve, cam flex valve & Smart Valve Positioners (DVC 6000 Series Fisher).

5)Fire & Gas Detection: IR gas detectors (Point Type) & Open Path Gas Beam Detectors (Sieger/Zellweger), Catalytic Gas detectors (sieger), Flame detectors, Smoke Detectors heat detectors (Thorn), Hydrogen gas detectors (Sieger).

SYSTEM:

1) Honeywell PKS C - 300 Loop checking and function checking, Commissioning & Maintenance

2) Honeywell TDC-3000 Loop checking, function checking and Commissioning.

3) PLC Allen Bradley Loop checking and function checking and Commissioning.

4 ) Honeywell TPS System Loop checking and function checking,Commissioning

5) Emersion DELTA V DCS & SCADA System Loop checking and function checking, Commissioning & Maintenance

6) Yokogawa Centum CS 1000 DCS Loop checking and function checking, Commissioning

COMPUTER KNOWLEDGE : MS Office.

Date: Bhavesh S. Mistry



Contact this candidate