Post Job Free

Resume

Sign in

Power Plant Engineer, Senior engineer - control and instrumentation.

Location:
Hyderabad, Telangana, India
Posted:
February 27, 2017

Contact this candidate

Resume:

D.S. Poorna Chandra

*/*/****

D.No:*-**, Kolimi Street, Bangarupalyam, Chittoor(DIST), AP

+91-958*******

acy1bf@r.postjobfree.com

acy1bf@r.postjobfree.com

DOB: 23rd August 1990

Senior Engineer- Control & Instrumentation

O B J E C T I V E S

I am looking for a good position in the field of instruments and automation in a prestigious company where my previous skills and capabilities can be put to efficient use. I possess effective organizational skills and the ability to supervise a team and achieve the Goals of our company. E D U C A T I O N

Course Institution University/

Board

Year of

Passing

Marks

%

B.Tech.

(ECE)

N.B.K.R.Institute of Science &

Technology, Vidyanagar.

S.V. University 2012 81.03

Intermediate Sri Chaitanya Junior College,

Tirupati.

Board of Intermediate,

Andhra Pradesh

2008 96.20

SSC St. Mary’s High School,

Bangarupalyam.

State Board,

Andhra Pradesh

2006 89.33

E X P E R I E N C E

Sr. Engineer-Control & Instrumentation TPCI L, A Sembcorp Gaya t r i Company August 1, 2012 – Till Date

Erection, Commisioning & Maintenance of C&I in 2*660MW coal fired thermal power plant D.S. Poorna Chandra

Page 2

S K I L L S :

Involved in the Erection,maintenance, commissioning and co-ordination of instruments and control systems in Power Plant, Desalination Plant, Fuel Oil system, Coal Handling Plant, HVAC & Ash Handling plants from the start till the end.

Effectively involved in the Material storage, Identification of materials, Review of Engineering drawings, Cable schedule preparation, coordinating with EPC contractor in completion of all types of job.

Also worked with Safety team for 3 months for the safety related issues clearing, conducting tool box talks, Safety training programs to avoid accidents in Power plants. Configuring and faults diagnosis of PLC, DCS, SCADA, RTU, Analyzers and Control Loops. o DCS : Foxboro DCS, Invensys

o PLC : Schneider PLC with Unity Pro and Alan Bradley PLC for CPU unit & ABB PLC for coal Handling plant.

o SCADA : Schneider Vijeo citect.

Installation, calibration and loop checking of the field instruments ( Emerson Rosemount, ABB, Endress & Hauser, Bently Nevada, Honeywell, Yokogawa) Maintenance and calibration of the control valves ( Pneumatic, Part turn, MOV, NRV ) of Severn Glocon, Fisher, Rotex, Auma matic with smart positioners. Experienced in flow meters configuring (electromagnetic, orifice plate, ultrasonic) of ABB, Rosemount, Krohne, E&H etc.

Designing, Implementing and Commissioning of new control loops as per site requirements. Review of control philosophy, P&I diagrams, instruments list, flow chart Preparation of Standard operating and maintenance procedures during O&M phase. Preparation of BOM, Cable schedule, JB schedules and maintaining spares by procuring in cost-effective manner.

Also worked with Stores department in the effective way of storing and maintaining materials for the erection and commissioning

Preparing master data sheet for PM schedule; ensuring safe and efficient performing of Corrective Maintenance.

Technical Support for the instrumentation team.

Experienced in the field instruments and control systems procurement activities Spares balance investigation and inventory control for all instruments’ spare parts Excellent communication interpersonal skills.

D.S. Poorna Chandra

Page 3

O R G A N I Z A T I O N A L E X P E R I E N C E :

Responsibilities:

To make sure that the C&I equipments are available without any breakdowns by clearing all maintenance related works by coming in shifts.

Leading a team of twenty instrument technicians

Reporting periodically to Maintenance Manager; preparing KPI, PM and CM reports. Troubleshooting the totally integrated automation of Schneider software and hardware. Establishing communication & troubleshooting of Media converters & profibus communication between field and the control room; comprising of 2 pair hot/standby controllers and pair of dual redundant servers.

Planning required up gradation for instruments to achieve production quality and cost minimizing.

Maintenance and calibration of pneumatic control valves and part turn actuated valves Maintenance and calibration of different analyzers : Conductivity, Chlorine, PH, SDI, Turbidity, TDS

Maintenance and calibration of flow meters (electromagnetic, orifice plate, variable area, turbine, ultrasonic of ABB, Krohne, Rosemount. Maintenance and calibration of transmitters PT, LT, TT, DPT (Emerson Rosemount, Endress & Hauser, ABB).

Ensure Spares balance and inventory control for all instruments’ spare parts Calibrating of weighting systems for Coal Handling system. Planning and implementing additional control loops as per site requirements. T R A I N I N G :

Vijeo-citect training at Schneider office, Delhi

Basics of Unity-pro training @ Schneider office, Delhi D.S. Poorna Chandra

Page 4

Attended Factory acceptance test of Schneider PLC

OTS Training at Invensys Hyderabad

H O B B I E S & I N T E R E S T S :

Playing games – Cricket, Volleyball, Chess and TT.

Going on adventure tours with friends

Started Eye Cross Foundation for promoting Eye donation awareness by conducting camps while we were in college.

Conducted ECF-3K run in collaboration with our company’s CSR to promote Eye donation in Nellore.

I T S K I L L S

Operating systems : Windows XP, 7, 2008 Server

Programs : Office Tools.

Internet : Very good

PLC Programming : FBD & Ladder Diagram

PC Networking : Very good

PC HW maintenance : Experienced

L A N G U A G E S

English, Hindi: Fluent; read, write and speak

Telugu: Mother tongue

D E C L A R A T I O N

I hereby declare that all information stated above are true to the best of my knowledge. D.S. Poorna Chandra

D.S. Poorna Chandra

Page 5



Contact this candidate