Post Job Free
Sign in

Customer Service Technician

Location:
Quezon City, NCR, 1109, Philippines
Posted:
February 27, 2017

Contact this candidate

Resume:

Elmer Reynante Dela Cruz

*** ****** **** **. ****. Commonwealth Q.C.

H.V.A.C. Technician

+639********* / +639*********

***********@*****.***

WORK SUMMARY

Company: INSTITUTE OF PUBLIC ADMINISTRATION

Contact person: Chief engr. Irfan ali khan

Contact #: +966 011******* / 011*******/+966*********

Position: H.V.A.C. Technician

Date: November 6, 2006 – June 15, 2016

Location: Farazdaq St. Riyadh, Kingdom of Saudi Arabia

(Duties and Responsibilities)

* Project*

*Preventive Maintenance

*Repair Defective A/C and Refrigerator Units

*Installation and Relocate the A/C Units like Split type, Package type, wall and floor mountain window type ceiling type ceiling cassette type.

*Overhauling of Compressor Motor

*Troubleshooting of all A/C problems

*Repair A/C Ducting

*Servicing in Housing Facilities by Job Order

* Job Description*

Daily Routine Morning Check up

*Check chilled water temperature supply and return

*Monitoring and check up of chiller compressor motor

*Checking refrigerant high side pressure and low side pressure

*Checking oil pump pressure

*Checking voltage and ampere of compressor motor and condensing motor magnetic contactor and breaker

*Checking expansion valve and motorize valve

*Checking A.H.U. motor units V/belt coil and air filter if dirty

*Checking primary pump motor and secondary pump motor

*Checking expansion tank water pressure supply and return water

*Checking air supply temperature and room temperature by using laser gun temperature

*Checking fan coil unit and exhaust fan motor in rooftop

Preventive Maintenance

*General cleaning of chiller units brand carrier calalily condensing coil back to back by using pressure washer

*Dismantle of condensing motor to change new bearing

*Blower of all electronics p.c. board and all magnetic contactor and breaker

*Check compressor motor oil leak

*Add refrigerant 134a if necessary

*General cleaning of A.H.U. coil back to back and flushing the drainage

*Change new air filter

*Change new v/belt

*Greasing of all A.H.U. motor and fellow block

*General cleaning of all fan coil units remove fan blower to clean and change air filter

*Change fan coil motor if defective

*Check motorized valve of fan coil

*Check air supply 13 14 16 Celsius and room temperature 20, 21 to 24,

*Flushing fan coil units if our supply temperature 21 to 25 Celsius

*Change chilled pump motor bearing primary and secondary pump

Repair defective compressor motor of refrigerator window split type and other commercial units

*Change refrigerator compressor motor

Tools and equipment flaring tools swaging tools flier screw driver acetylene silver rod flux refrigerant 134a vacuum pump gauge manifold clamp tester sun paper soap for leak testing. Dismantle of old defective compressor motor, flushing the system to remove moisture then fixes the new compressor motor by using of acetylene leak testing vacuuming recharging test run and observation.

*Defective burn compressor motor of split type units

Tools and equipment flaring tools swaging tools acetylene nitrogen refrigerant 22 vacuum pump gauge manifold clamp tester silver rod flier allen wrench adjustable wrench sun paper soap for leak testing. Removed old compressor motor, flushing the system by using R-141 to push by nitrogen if the system is very clean now we fixes the new compressor motor using by acetylene and silver rod leak testing if no leak start to vacuuming until the moisture done we start to recharging the refrigerant put standing pressure then start the unit we add refrigerant to full charge and used clamp tester test run and observation.

Servicing Housing Facilities by Job Order

*repair not cooling a/c unit

*Repair defective refrigerator minor or major problem

*Repair defective washing machine

*Repair defective heating ventilation

*Repair exhaust fan

*Repair water pump

Installation of split type package type wall and floor mountain window typed and other commercial units

*We install and relocate the commercial units

*Fabricate of a/c bracket

*Re pipe the old copper tube

*Survey and estimate the materials before we install the unit

*Test run and observation

Overhauling of chiller compressor motor

*Tools and equipment,socket wrench, combination wrench, adjustable wrench, allen wrench, torch wrench, pipe wrench, fliers, screw driver 1 set, recovery pump, lifter, nitrogen,vacuum

*Closed the main breaker

*We recovery the refrigerant closed the suction and discharge valve

*Removed the cylinder head

*We full out the compressor motor by using chain block

*Bring to our work shop to repair and overhaul

*We remove defective connecting rod and piston

*We remove crankshaft to bring machine shop to build up if minor problem the crankshaft we used sun paper to alignment the connecting rod

*We clean the compressor housing and filter strainer by using thinner

*We fix the all part of compressor motor like crankshaft piston connecting rod all gasket

*Fixes the cylinder head need used torch wrench

*We add partial suniso oil

*Start testing compressor motor check amperes if good running condition

*We deliver to the units to install test run and observation

Company : RUSTAN SUPERSTORE ADMINISTRATION

Position : A/C technician

Date : April 23, 2003 – March 18, 2006

Location : 2nd floor Rustan Superstore Building Araneta Center Cubao Quezon City

Contact # : PABX 913 5575 to 76 / 108,103,107 DL, 911 24 39 / Fax # 912 81 60

Contact Person : Executive Administration Head -George t. lao

(Duties and Responsibilities)

*Project*

*Maintenance of mall Facilities

*Preventive Maintenance

*Repair of cooling Tower

*Overhauling of compressor Motor

*Daily routine morning check up

*Manual starts up and closed chilled water pump compressor motor and cooling tower

*Repair refrigerator and commercials units in mall facilities

*Repair chilled water pump

*Maintenance of generator brand onan caterpillar

*Repair all exhaust fan

Preventive Maintenance

*General cleaning of cooling tower by using pressure washer change gear oil of cooling tower motor drain water remove all clogging in water filter of cooling tower

*General cleaning of all A.H.U. and air filter

*General cleaning of condensing coil chiller by using chemical

*General cleaning of evaporator coil chiller by using chemical

*General cleaning of fan coil units

*General cleaning of all commercials a/c units

Overhauling of compressor motor brand trane reciprocating

*Tools and Equipment socket wrench, tork wrench, adjustable wrench, allen wrench, pipe wrench, fliers, vacuum pump gauge manifold, nitrogen, refrigerant.

*Recover the refrigerant

*We removed the cylinder head

*Change new gasket

*Change new spare parts piston ring connecting rod

*Alignment of connecting rod to crankshaft by using sun paper

*Cleaning compressor motor housing and filter strainer

*We fixes cylinder head by using tork wrench

*Leak testing vacuuming recharging

*Test run and observation

Repair of cooling tower

*Change cooling tower motor bearing

*Change gear oil

*Removed dirty filler

*Drain dirty water in cooling tower

Daily routine opening and closing

*Morning start up cooling tower, chilled pump motor condensing pump and start compressor motor

*Start up all A.H.U. and fan coil units

*Monitoring the condition of compressor motor

*Monitoring of all facilities

*Check room temperature

*Check chilled water supply temperature and return temperature

*Shifting duties

*Checking A.H.U. v/belt

Repair refrigerator and commercial units in mall facilities

*Job order tenant problem

*Repair and trouble shooting

*Change compressor motor

*Recharging of refrigerant

*Change spare parts

*System reprocessing

Maintenance of generator

*Checking the diesel if full tank

*Checking batteries

*Manual charging of diesel tank

*Check oil and water coolant

EDUCATION & TRAINING

Refrigeration and Air-Condition Engineering Technician

Quezon City Polytechnic University, Quezon City, Philippine

1998 to 2001

Refrigeration and Air-Conditioning Technician

E.A.R.N School Quezon City Philippines

1996 to 1997

Driving with troubleshooting

Xavier Technical Training Center Corp.

Commonwealth Quezon City

November 5, 2016

ACHIEVEMENT & AWARDS

Licensed Refrigeration and Air-Condition Technician

License No. 001*********

Gold Medalist (District) – 1st Quezon City Skills Olympics

August 14 to 24, 2000

RAC – Open Category

Silver Medalist (Regional) – 9th Metro Manila Sills Competition

December 5 to 6, 2000

RAC – Open Category

Gold Medalist (TUP) – 2nd Invitational Skills Competition

November 26 to 27, 2001

RAC – Open Category

Professional Driving Licensed no: N0217000379

Valid until: March 3, 2021/R.C., 2

SKILLS

Has good amount of customer service and interpersonal skills. Capable to work under pressure with developed oral and written skills; and most importantly, has a strong grasp on things that should be learned on a limited time. Highly motivated, competitive, analytical, creative, and can deliver good results with minimum supervision.

PERSONAL INFORMATION

Date of Birth : May 3, 1979

Civil Status : Married

Nationality : Filipino

Religion : Roman Catholic

Height : 5’8”

Weight : 140lbs

Language : English & Filipino, Arabic

Philippine Address : 128 Yellow bell Street, Brgy. Commonwealth, Quezon City

Philippines



Contact this candidate