JONATHAN E. PERRY
I am a contracting power plant professional with over 23 years of power plant industry experience. I started my career in the United States Navy as an Engine Room Operator and have since held titles of Operating Engineer, Auxiliary Operator, Control Room Operator, Mechanical Supervisor, and PTW/LOTO Coordinator. I have experience working directly with major corporations such as General Electric and Calpine Corporation, Gama Power systems, Metka Power Projects, Turner Construction, SWES. I have operated and services many large industrial units including GE LM/TM2500, LM600, GE Frame 6B, GE 7FA, and GE 9fa, 9fb, Siemens V84 GTG, combined with various Steam Turbine Generators in a combined cycle and in a cogeneration setting. I am also qualified to work from the control room. As part of the commissioning group (mechanical and operations), we assist the TA (technical advisor) with erection, oil flushing, pressurizing the generator with air, CO2 air and hydrogen. My objective is to come right in as a valuable asset to the team and safely get the job done correctly.
EXPERIENCE
CONTROL ROOM OPERATOR
SNC LAVALIN (CPV PROJECT 725 MW CCPP)
NOV 2016- PRESENT
Current role of Control Room Operator for a 2x1 plant with 2 GE 7FA.05 plus a GE D11 steam turbine. GE Mark IV DCS Controls operating system and plant controlling medium. Using a Aux Boiler for setting vacuum and steam seals. Operated for SNC Lavalin from steam blows to plant over CPV/Ethos Energy (OM Group)
CONTROL ROOM OPERATOR
PP12 COMBINED CYCLE POWER PLANT 2400 MWKSA (90-DAY CONTRACT)
FEB 2016- JUNE 2016
Responsible for the start up and Commissioning/Operations for Power Block 2. 8GE 7FA.05 combustion turbines and 2 Alstom steam turbine generators. Responsible for commissioning all BOP & Alstom HRSG equipment from first fire through Sigma blows up until first synchronization.
CONTROL ROOM OPERATOR
DUBA POWER STATION, KSA
AUG 2015- DEC 2015
Start-up and commissioning of TM 2500 unit.
Operated the unit on a daily basis until site was handed over to client. Unit was fired on liquid fuel. Woodward Micronet DCS controls system.
CONTROL ROOM OPERATOR
HURGHADA POWER STATION, EGYPT
JULY 2015- JULY 2015
Start-up and commissioning of 6 GE LM6000 (30-DAY CONTRACT)
Start-up LM600 units and run through testing phase with controls TA. Operations support until client staff was trained and could operate independently. Woodward Micronet DCS controls system.
OPERATIONS SHIFT SUPERVISOR
YANBU 2 POWER AND WATER
JULY 2014- AUG 2015
Start-up and Commissioning Control Room Operator
690 MW Power Station 3 Oil Fired Boilers Single Pressure (B&W) 3 Dooson Steam Turbine Generators, Ovation controls system, FGD, Electrostatic precipitators. Firing on HFO, light Arabian Crude Oil
OPERATIONS SHIFT SUPERVISOR OFS
ERZIN, TURKEY
NOV 2013- MAY 2014
Start-up and Commissioning Control Room Operator for GE at Erzin/Hatay CCPP Project
870 MW CCPP, 2 GE9FB Gas Turbines, I Skoda Steam Turbine with GE Generator, 2 Doosan 3-pressure HRSG’s (Mark Vie controls)
COMMISSIONING OPERATOR NEXT ERA RESOURCES
JULY 2013- NOV 2013
Genesis Thermal Solar Power Project Units 1 & 2
Responsible for the safe operations of the facility during start-up and commissioning activities. With the use of parabolic trough-type collectors using HTF steam generators along with 2 Siemens steam turbine generators rated at 125 MW each. Also responsible for training the client’s operational staff on Siemens T-3000 controls system. Directed client through start-up to acceptance.
OPERATIONS SHIFT SUPERVISOR TRANS GLOBAL ENERGY
SAMSUN, TURKEY
SEPT 2012- MAY 2013
Responsible for Commissioning/Start-up and Operations of 860MW Combined Cycle, 2 GE Frame 9FB Single Shaft with Condensing A-16 Steam Turbine By-pass Cascade Reheat Operation. Two HRSG’s each capacity 300,000 lbs/hr with HP/IP/LP multi drum configuration. Metso Automation DCS Control System.
Operated Gas Turbine, Steam turbine, BOP during commissioning phase, contractual testing phase, until turnover to the client. Additional equipment, circ water pumps, condensate pumps, aux boiler with dual burner, gas regulating plant, heating boilers, demin plant with reverse osmosis unit, wastewater treatment plant.
LOTO COORDINATOR, GAMA POWER SYSTEMS
SHATURA, RUSSIA and SURGUT, RUSSIA
OCTOBER 2010- AUG 2011
Provided assistance by coordinating the LOTO Program through start-up to COD of a 435MW CC POWER PLANT (D11 steam turbine generator) in Shatura and also for a 800MW CC power plant in Surgut, Russia
Setup, implement and operate Commissioning permit to Work System (PTW)
Understood and implemented the various requirements for hot, cold, and confined space permits
Day to day review of permits with respect to PPE, isolations, electrical and mechanical lock-out & tag-out, barricading and depressurization of equipment, pipework and instrumentation to effect safe work through PTW System
Able to read Process and Instrumentation Diagrams (P & IDs) or equivalent
Able to read and understand Method Statements
Maintain “live” systems list in PTW office and have day to day understanding of status of “live” systems to enable PTW to be issues in a safe and efficient manner
Effectively coordinate and record PTW activities including maintenance of PTW location plot plan and register to ensure safely is maintained at all times in ongoing Construction/Commissioning work areas with no clashes
Enforce and ensure applied permits properly describe the scope of work and are accompanied by necessary documentation such as marked-up P7IDs, Method Statements, and JHAs
Supervise Operations and Commissioning Engineers with respect to application of lock-out & tag-out practices in issuing PTW
Final review, sign off, and issue of PTW to sub-contractors on behalf of Commissioning group
Archive PTW in logical manner
Provide regular audits of PTW system to ensure compliance with Project Procedures and Safe Work Practices
OPERATIONS SUPERVISOR, GENERAL ELECTRIC
THIVA, GREECE
MAY 2010- OCTOBER 2010
Provided assistance to 435 MW combined cycle power plant GE 9FB single shaft w/air-cooled condenser
Performed start-up testing requirements as per contractual agreement with client
OPERATIONS SUPERVISOR, GENERAL ELECTRIC
DOHA, QATAR
FEBRUARY 2010- MAY 2010
Start-up and commissioning of 4 GE 9 FA gas turbines in a simple cycle setting Steam turbine was not assembled.
Performed start-up testing requirements as per contractual agreement with client
START-UP/COMMISSIONING CONTROL ROOM AND FIELD OPERATOR, GRANITE SERVICES INTERNATIONAL ENERGY, MARAFIQ
IWPP PROJECT, JUBAIL, SAUDI ARABIA
JUNE 2009- JAN 2010
Provided assistance to 2750 MW combined cycle, dual fuel, duct-fired, evap cooling, GE 7 FA gas turbines, Dooson HRSGs, GE D 11 steam turbine, Mark Vie, Desalination Plant
Start-up and commissioning of power blocks #1, #2, and #3 which are in a 3x1 configuration, first fires, steam blows, system alignment for fuel gas, fuel oil, fuel oil flush, duct burners, hp feed pumps, feedwater, hydrogen for gas turbine generator as operations shift supervisor instrumental in the training and field development of the operations/maintenance group in operations/commissioning discipline phase of gas turbine, steam turbine and HRSG. First fire/stram blows on units 11, 12,13, 21, 22, 23, 32, 33, and 41. STG 10, 20, 30, and 40. Performed start-up testing requirements as per contractual agreement with client.
POWER PLANT OPERATOR, NORTH AMERICAN ENERGY SERVICES, TENASKA KIAMICHI GENERATING STATION
KIOWA, OK
OCTOBER 2007- FEBRUARY 2008
Provided assistance to Shell Oil in Texas through electrical generation process.
Responsibilities included start-up and shut-down of 1200 mega watt combined cycle power plant which included GE 7 FA gas turbine engine and GE D 11 steam turbine. Performed routine rounds, water analysis on boiler feed water, plant start-up and shut-down, hot start/cold start. Perform any and all on-line/off-line procedures on gas/steam turbine (i.e; bleed and feed) Took lake water and purified to become feed water by use of SCU’s (solid contract units) multi-media filters, reverse osmosis and demin trains through the use of chemical treatment. Perform all activities in operator capacity which included LOTO, writing of plant permits for hot work, confined space, etc. Equipment included start-up fuel gas heater, fuel gas scrubber, duct burner gas skid/regulator, raw water supply storage and pretreated, close cooling water system, boiler feed system for HP/IP econ, desup spray water, 11 stage horizontal ring segment single speed centrifugal pump, HP discharge flow @ 1002 GPM, HRSG, HP steam, hot reheat steam, low pressure steam, circulating water, condenser air extraction, combustion turbine, DCS, GE MK V controls, Lock Out Tag Out (LOTO) for all systems air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
POWER PLANT OPERATION, BLUE WATER ENERGY SOLUTIONS, INC.
CORN PRODUCTS
BEDFORD PARK, IL
MARCH 2007- JULY 2008
Provided assistance such as power and steam to an agricultural processing plant.
Responsibilites included auxiliary operations (operating and maintaining plant) on 1.1 million lbs/hr CFB boiler. The CFB boiler was coal-fed with a limestone pulverizer. I operated from the Control Room and also spearheaded the OJT training for auxiliary operations for plant turnover. Equipment consisted of four coal feeders, switchgear 4160/480 compressors, cyclone separator, stripper cooler, fly-ash hopper, bag-house primary and secondary air fans, induced draft fan. Boiler consisted of steam drum, primary super-heater, convection stage, finishing super heater, steam attemporation valves, soot blowers, boiler feed pumps were electric-driven. Lock Out Tag Out (LOTO) for all systems air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
STATIONARY ENGINEER, PFIZER, INC.
JONES, LANG, & LASALLE
ST. LOUIS, MISSOURI
NOVEMBER 2006- MARCH 2007
Provided assistance such as steam, water, and electric to a pharmaceutical plant
Responsibilities included maintaining and operating all boilers and chillers in central utility plant, water chemistry analysis on towers and boilers, equipment: 3 steam boilers set at 220psi, 3 hot water boilers set at 220 degrees, 4 1200-ton chillers, and 2 glycol chillers and 2 3-cell cooling towers. Operated from control room on Metasys Energy Management System, Lock Out Tag Out (LOTO) for all systems- air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
STATIONARY ENGINEER MICRON, INC.
MANASSAS, VIRGINIA
SEMI-CONDUCTOR PLANT
Four 700-horsepower package boilers, 10 chillers
Responsibilities included running the boilers as well as the chill water plant
WASHINGTON GROUP
FAIRFAX, VIRGINIA
NOVEMBER 2004- MAY 2005
Provided assistance such as electricity, power, and steam to a semi-conductor plant
Responsibilities included maintaining and operating all boilers and chillers in central utility plant, water chemistry analysis on towers and boilers, equipment: 3 steam boilers set at 220psi, 5 hot water boilers set at 220 degrees, 7 1200-ton chillers, and 2 glycol chillers . Operated from control room on lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
POWER PLANT OPERATOR A, GE ENERGY
BAYONNE, NEW JERSEY
OCTOBER 2003- SEPTEMBER 2004
Provided assistance such as electricity for sale to New Jersey Central Power and Light
Responsibilities included overseeing field operations, monitoring and maintenance of plant equipment, performing rounds of boilers, auxiliary building, cooling towers, storage tanks, HRSG, auxiliary boiler and motor control center. Maintained logbooks. Performed chemical analysis, electrical troubleshooting task, inspections and overall system improvement task. Worked with GE Frame 6B with Mark IV controls. Plant was in a 3x1 configuration. System included MK IV. LOTO for all systems Air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
POWER PLANT OPERATOR A and B
DUKE ENERGY
DALTON, GEORGIA and GRANBURY, TEXAS
OCTOBER 2002- OCTOBER 2003
Provided assistance to plant start-up
Responsibilities included overseeing field operations, monitoring and maintenance of plant equipment, turbine hall building, auxiliary building, cooling towers, storage tanks, HRSG, auxiliary boiler and motor control center. Maintain logbooks, perform chemical analysis, electrical troubleshooting task, inspections and overall system improvement. Performed GE 7 FA GTE along with Alstom STG, MK VI controls with a 1240 MW CC plant in a 4x2x2 configuration. LOTO for all systems air, gas water, lube oil gas turbine, steam turbine switch gear, breakers, buckets and associated sub systems.
POWER PLANT OPERATOR A and B
CALPINE ENERGY
SAYERVILLE, NEW JERSEY
JUNE 2001- SEPTEMBER 2002
Provided assistance such as electricity for sale to New Jersey Central Power and Light
Responsibilities included performing as an Auxiliary Operator for Calpine where the duties included making rounds, operating the equipment and working with the shift supervisor to safely and successfully meet the operations plan. Plant start-ups and shut-downs. Water chemistry, plant walk through prior to start-up. This involved working on different rotating shifts and performing general maintenance activities. Plant in 1x1 configuration. System included MK IV, LOTO for all systems, air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
STATIONARY ENGINEER
CONSOLIDATED ENGINEERING
WASHINGTON, DC
DECEMBER 1998- JUNE 2001
Provided high pressure steam and HVAC to EPA and US Customs Headquarters at the Ronald Reagan Building
Responsibilities included maintenance and troubleshooting tasks of eight 12-ton york centrifugal chillers, various pumps, and sewer ejector systems. Performed preventative maintenance of HVAC (air handling units) VAV boxes and associated pneumatic equipment which included Landis Energy Management Systems. Performed maintenance and troubleshooting tasks on high pressure steam and steam reducing stations. Cleaned steam generator units, package boilers, and electric lights. LOTO for all systems air, gas water, lube oil gas turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
GSM PETTY OFFICER 3RD CLASS
UNITED STATES NAVY
GREAT LAKES, IL and NORFOLK, VA
MARCH 1993- NOVEMBER 1998
Responsibilities included supervising 5 employees as Engine Room Operator. Performed and operated advanced and immediate maintenance to components of LM 2500 and Allison 501K 17/34 gas turbines and their propulsions-related auxiliaries support systems including brakes, clutches, shafting and bearings, controllable pitch propellers, hydraulic systems, purifiers, pump and pump-related systems, heat exchangers, high and low pressure air compressors, reduction gears, turbine generator systems and waste heat recover boilers on DDG-51, CG-47,
DDG-993, and DDG-963 class ships. Operated main propulsion and electrical and control consoles as gas turbine powered vessels from electrical generating plants as well as from remote locations. Monitored and read instruments such as ammeters, voltmeters, frequency meters, and temperature pressure indicating devices. Boroscoped main engines and generators for preventative maintenance and scheduled inspections. Maintained engineering logs for all work performed. Stood watch. Obtained working knowledge of a broad variety of mechanical fundamentals as it relates to engineering such as tools and uses, basic physics, thermodynamics, hydraulics, pneumatics, corrosion control, electrical and electronics, engine support systems and controls, AC/DC electrical motors and generators and engineering administration. LOTO for all systems air, gas water, lube oil turbine, steam turbine switch gear, breakers/buckets and associated sub systems.
MACHINERY/MECHANICAL-RELATED SKILLS
GE FRAME 6B/7FA/9FA/9FB gas turbines with GE Mark V-VI controls integrated along with DLN 2.6 to lower nox emissions
3 Henry Vogt heat recovery steam generators with HP drum operating pressure at 710psi at 896 degrees rated at 132 kpph, and IP drum operating pressure at 315 psi at 511 degrees rated 25 kpph and LM drum 24 psi at 265 degrees at 19 kpph, DA drum with redundant dual discharge feed water pumps and Babcock/Hitachi high temp SCR with NH3 injections.
1 GE straight condensing single automatic admission extraction steam turbine with GE Mark III controls, generator rated at 61.4 Mw Ecolair surface condenser with guillotine valve and 5 cell cooling towers, 138 KV Nissin SF6 insulated switchgear.
Nebraska boilers rated at 70 kpph each, maw of 300 psi amd Babcock and Wilcox boilers with super heaters rated at 70 kpph each, mawp of 750 psi and operating pressure of 250 psi.
Siemens V84.3A combustion turbine (170 MW) with unfired Vogt-NEM HRSG with Siemens HR3B burner.
HIGHLIGHTS OF PROFESSIONAL QUALIFICATIONS
QUALIFICATIONS:
Naval-Certified- Enlisted Surface Warfare Specialist (ESWS)
Propulsion Auxiliary Control Console (PACC) A
Engine Room Operator (ERO)
3M Qualified Maintenance
CERTIFIED LICENSES:
Civial-Universal CFC
Maryland 1st Class Stationary Engineer
New Jersey 3rd Class Stationary Engineer (Blue Seal)
U.S. Navy’s General Shipboard Firefighting
EDUCATION
Benedict College
Columbia, South Carolina
August 1992
Major: Business Administration
55 hours completed
Address: 3023 Galilee Ave. Zion, IL 60099
E-mail: **********@*******.***
Telephone: 1-847-***-**** (mobile)