*Yrs expd. Electrical Engineer
R.Hemanathan C/o. No 8 Athreya Street,
Sullurupeta, Nellore - 524121
E-mail:**************@*****.**.**
Contact No: +91-741*******.
Career Objective
Seeking for a senior level assignment in emerging field with reputed organization, where I can utilizes my diverse experience to positively impact on company profitability.
Academic Qualifications
2009 B.Tech Graduation (Electrical & Electronics Engg.) from Madha Engineering College, with an aggregate of 65.06%.
2006 Diploma (Electrical& Electronics Engg.) from Sri krishna polytechnic college, with an aggregate of 81.67%.
2002 S.S.C from Dr.Radhakrishna boys higher secondary school, with an aggregate of 63%.
Certification
Done a PLC automation course at proflic, and awarded grade ‘A’ Certification .
Professional Profile
Rich experience of 5 Years in Design, application, Operation & maintenance of Electrical & instrumentation equipment’s.
Experience on power system control, protection, power quality analysis & Load shedding etc.
Having experience in Operation of SIEMENS-S7, GE-fanuc PLC’s, AC Drives& Field instruments.
Having Experience in Operation of GE – Fanuc (I/O series 90-30,90-70, versa max nano/micro plc, versa max PLC) & Software of Proficy machine edition (5.7,6.0,7.0 & 8.5).
Having Experience in operation of Scada updated version of Cimplicity 8.1.
Having experience on selection, Operation& Maintenance of
Breakers (ACB, VCB, SF6) both HT & LT.
LT & HT Motors & Switchgear, Power Transformers and DG set.
MCC, PCC, LT&HT Control wirings & APFC System.
Air compressors, Water cooled chillers, UPS & EOT Cranes etc.
Experience on Condition Monitoring (Thermography) of plant equipment’s to reduce breakdown time AND knowledge on Mechanical equipments.
Planning & Execution of Development activities / projects within time & budget.
Having experience in Procurement, finalizations of technical specification & quotations, Negotiation, Vendor selection with Quality& time bounded and release the PO & WO.
Experience in safety implementation & 5’S systems (lock out-Tag out, Risk assessment).
Experience on Documentation & Audits of
ISO- 9001, EHS-14001& OSHAS-18001.
MIS, MTBF, Cost control, Power calculation & Budget planning etc.
Experience in SAP Operating system for plant Operation & Maintenance activities.
Work Experience
Worked as an Electrical Engineer in M/s. Regen Powertech Pvt. Ltd. (REGPL), Tada from March - 2012 to Still .
REGPL is the third largest company in Manufacturing& commissioning of Gear less WIND ENERGY CONVERTERS having a capacity of 1.5MW.
Responsibilities:
Experience in troubleshooting of 33Kv switch yard.
Maintenance& Troubleshooting of
Vacuum impregation plant, Baking Oven,EOT & Semi portal crane.
HT& LT switchgear( VCB,ACB,SF6), LT Motors, Relay coordination& protection,
Power Transformers (1000& 2000 Kva), Battery charger and compressor.
Modification& improvement activities involvement and execution, like Cable selection, Feeder rating selection, Protection arrangement etc.
Troubleshooting of MCC& PCC control wiring and modifications, if necessary.
Reduction of down time with Implementation of new ideas& Preventive maintenance activities.
Testing of Transformers-oil filtration, Relay testing etc. as per statutory requirement.
Spares inventory planning, controlling& procurement as per allocated budget.
ISO documentation, Cost Review& consumption report making.
Implementation of 5’S system& follow-up at workplace to reduce accidents/losses.
SAP Operating system for plant activities like O&M, PR and WO etc.
Entry level Knowledge on Captive power plants, synchronization.
Worked as anAppretenice in M/s.Madraus Rubber Factory (MRF), Arakonam from March- 2010 to March-2011.
Worked as an Site Engineer in M/s.Maheswari Enterprises Engineer, from May-2009 to March-2010.
Having Technical exposure, Operational& Maintenance Experience in:
33Kv/430V Outdoor Switchyard, 33KV/430V Substation, with their associated Protecting Relays.
Circuit Breakers of SF6, VCB’s& ACB’s (having rating upto 3200A) with different makes.
Knowledge about Siemens PLC: S7-200, 300 and Ge-fanu with Prolific system. PLC programming techniques as per standard applications and making changes according to the user requirements.
AC drives of different makes i.e. Siemens Micro Master, ABB,Schneider,bonfiglioli & Demag upto 55 kw capacity etc.
Power transformers with ONAN type cooling, having a capacity of 1000KVA (33Kv/430Kv), 2000KVA(33Kv/430v),Transformers with On-Load Tap changers.
Different type of Motor starters like DOL, Star-Delta, Soft starters, SPRS, GRR& LRS for slip-ring motor.
Diesel Generators upto capacity of 2x1500 KVA& 2x500KVA with their Protective relays, Breakers and Auto Source changeover relays& synchronizing system.
HT& LT motors and Feeder Protection relays include SPAM, SPAJ, SJ7062, P341, Num. distance& Differential, SEPAM and their Control wiring etc.
APFC panels& UPS system upto a capacity of 30Kva.
Knowledge in pneumatic cylinders, FRL Systems& different type of Valves etc.
FIELD Instruments like Proximity sensors, level sensors, Thermocouples, Differential Pressure transmitters, Pneumatic valves& Flow switches etc.
EOT Cranes, designed by DEMAG upto a capacity of 60Ton and OVEN’s having a capacity of 300KW.
Having Experience in project works:
Analyzing& preparation of Single line Diagrams, Schematic diagrams, tender specifications, customer specifications.
Design, approval& Inspection of MCC, PCC, Breakers.
Testing& commissioning of LT panels, Transformers, Motors etc.
Experience in calculation of Required Cable sizes, Transformer capacity, Motors etc. as per requirement.
Preparation of quotations, Finalization, Procurement& monitoring of inward etc.
Check the quality, time boundary with vendors in reasonable cost.
Reach the Management targets, procurement as per standards& approvals.
Experience in erection& testing of Power Transformers and HT& LT Motors.
Experience in calculation, erection& commissioning of APFC panels for P.F improvement.
Planning& execution of day to day activities and reporting to next level management.
Ensure proper planning, execution& completion of project within the time period.
Experience design& installation of lighting Transformer for reducing the lighting maintenance cost.
Achievements
Improved the existing Power factor from 0.92 to 0.99 by installing the new Capacitor banks.
Maintain& implement the Preventive maintenance records for improving plant running hours& reducing the breakdown time.
Reduction the power cost Rs.5000/- per month by eliminate the plant ideal power consumption with introduction& operating in proper interlock mode.
Reduction of power consumption cost Rs.6000/- per month by distributing the lighting feeders properly.
Reduce the Non momentary cost in stores by proper utilization.
Passport details
Passport Number : J8531276
Date of Issue : 28.10.2011
Date of expiry : 27.11.2021
Place of issue : Chennai
Personal Profile
Name : R.Hemanathan
Nationality : Indian
Languages : English, Telugu, Hindi, Tamil
DOB : 26/01/1986
Address : S/o. K.Ramaiah,
D.No: 19A, Kanna biran nagar,
Tiruttani – 631209,
Thiruvallur dist.
Declaration
I here by declare that all information provided above is true.
Place:
Date: (R.HEMANATHAN)