Mahalingam Rajesh

Mobile +91-955*******

Email: acw9iq@r.postjobfree.com

PCN PAUT/TOFD- LEVEL II

PCN- LEVEL II (UT-3.1&3.2) Pcn number: 313053

AWS CWI Welding Inspector / Ndt Inspector / QA-QC Inspector

aws cwi No: 15032711 - ASNT–level ii (Rt,Ut,Mpt,Lpt)

CAREER OBJECTIVE:

Seeking a challenging career in a leading company, that matches my field, where my abilities and skills can be developed and knowledge can be applied.

PROFESSIONAL EXPERIENCE

Holding around 10 Years’ experience in PAUT/ TOFD NDT & QA/QC INSPECTOR in various aspects of quality assurance and Quality Inspection activities in onshore, offshore & Nuclear Power plant, shipbuilding (welding, piping, pipeline and NDT) Mainly carrying out Drawing verification, Final documentation preparation, Coordinating final certification process, reviewing and monitoring of Vendor / Sub-contractor’s documentation system. Worked with major clients in India, Singapore, UAE & EAST TIMOR under their internationally recognized standards.

TECHNICAL QUALIFICATION:

BRITISH INSTITUTE OF NON- DESTRUCTIVE TESTING

PCN- LEVEL II NUMBER : 313053

Ultrasonic Testing (3.1 & 3.2)

Phased Array Ultrasonic Testing (PAUT)

Time of Flight Diffraction (TOFD)

AMERICAN WELDING SOCIETY CERTIFIED WELDING INSPECTOR.

AWS CWI No: 15032711

AMERICAN SOCIETY FOR NON- DESTRUCTIVE TESTING:

NDT LEVEL II - ASNT-TC- 1A

Ultrasonic Testing

Radiographic Testing

Magnetic Particle Testing

Dye Penetrant Testing

[[SAFETY AND SECURITY:

Imparting training to personnel on occupational health, safety and firefighting.

Attend various safety courses like SIC – Singapore & Dubai.

Involved SIC for shipyard.

Safety Promoter

ACCADEMIC PROFILE:

Diploma in Mechanical Engineering.

Higher Secondary School Leaving Certificate.

COMPUTER PROFICIENCY:

Tomoview Interpretation

ES Beam Tool

Microsoft Office (Word, Excel)

Very good at searching and navigation the web

[[

EMPLOYMENT HISTORY

EMPLOYER : RCI Testing Inspection & Consulting Co .LTD. THAILAND

PROJECT : PRESALT FPSOs Project

CLIENT : TUPI BV

DESIGNATION : PAUT Coordinator

PERIOD : DEC 2015 TO April 2016

WORK SCOPE:

PAUT Cross Checking

Tomoview analysis activates as per the Codes and Liaison with Client.

Performed PAUT Structure and piping Joints.

Maintaining the NDT reports, in the job file as per the NDT methods

Conducting meeting and Discussion review the weekly and monthly performance.

Tomoview Software Analysis:

Familiarize with Tomoview menus, functions & Parameters.

Familiarize with data displays and converting data files.

Creation of display Setups (rst files).

Creation of Weld overlays.

Merging of data to analyze the data.

Sizing of defects (length & height) using 6dB drop & Maximum amplitude techniques.

Interpretation of defects (type of defect)

EMPLOYER : NES Global talent

PROJECT : SOLAN SUBSEA OIL STORAGE TANK

CLIENT : PERMIEROIL, DRY DOCK WORLD, DUBAI.

PROJECT DETAILS : SOLAN SUBSEA OIL STORAGE TANK (45MX45MX25)

DESIGNATION : PAUT & TOFD Inspector.

PERIOD : JULY 2013 TO JULY 2014.

WORK SCOPE:

Worked for Solan Subsea Oil Storage Tank Carried out PAUT / TOFD / UT Inspection of Structure and piping works and ensures compliance with established work procedures and project requirements.

Carried out PAUT/TOFD for inspecting Piping joints of various thicknesses of process piping joint and different materials like as a Carbon Steel, Stainless Steel, Super Duplex Stainless Steel

8 Blocks – 32 Sub Blocks Fabrication, Erection Joints and Pipe Joints (approx.- 7000 tons) .

Tomoview Interpretations and evaluation as per codes and standards.

NDE cross checking.

Ensure that sub-contractors comply with quality aspect at the worksite to client requirements.

Conducting meeting and discussions with sub-contractors to review the weekly and monthly welder performance and repair rate.

Review and approval of NDT reports.

Ensuring the Repaired joints is cleared as per the same NDT methods.

Maintaining the NDT reports, in the job file as per the NDT methods.

Evaluate the defects as per ASME section V & client specifications.

JULY 2007 to JUN 2013

EMPLOYER : CUTECH SOLUTIONS SERVICES PTE LTD, Singapore

DESIGNATION : PAUT / TOFD and UT Inspector

PROJECT VESSEL INVOLVED IN SINGAPORE .

Keppel Fels: (DIAMOND OFFSHORE DRILLING Project)

Ocean Shield Jack up Drilling Conversion (B282)

Keppel Shipyard Ltd Tuas (SBM Projects)

FPSO ASENG

FPSO CIDADE DE PARATY

FPSO ANCHIETA

FPSO BLUE WATER GLAS DOWR at Offshore (East Timor)

Keppel Shipyard Ltd (Benoi & Tuas Gul Yard

FPSO TGT

FPSO BW PIONEER

FPSO MAERSK PERGRINO

FPSO PETROBRAS -58

Sembawang Shipyard Ltd

FPSO BLUE WATER GLAS DOWR

DESIGNATION : PAUT & TOFD Inspector.

PERIOD : March 2012 TO June 2013.

WORK SCOPE:

Performed PAUT/ TOFD/UT on pipe to pipe, pipe to elbow, TKY, Brazing joints.

Tomoview Interpretations and evaluation as per codes and standards.

Carried out PAUT/TOFD for inspecting Piping joints of various thicknesses of process piping joint and different materials like as a Carbon Steel, Stainless Steel, Super Duplex Stainless Steel.

EXPERIENCE/SKILLS IN SHIPYARD

Experience in FPSO, FSO & LNG ship conversation projects activities in Singapore.

Performs PAUT/TOFD / UT- A, B & C scan Evaluation during piping inspection, Plates, and Structural welding.

Performs to Internal cross Checking for all NDT activates as per project specification & Codes.

Performs PAUT/TOFD and Ultrasonic testing of pipe welds in various material and diameter.

Perform internal, external inspection in vessels, tanks from ship and other structural’s in accordance with the company engineering & Clients requirements.

Flat tower erection and TKY joints, Turret all structure, gantry erection joints and moon pool structure erection joints Crane Erection High Thick wall TKY joint

Side shell bottom plate reaction joints, crane column erection joints,

High thickness plate Lamination Piping joints, process well-stream fluid system, Process Gas system, Injection water system.

Process Piping joints, turret to process system Connecting high thick piping system

Carry out Ultrasonic Testing on Various types of Structures, like TKY joints Jack case Spud can, Crane column Cantilever Structure Erection joints.

Carry out UT on Leg to Spud can and Leg to Jack case erection leg brazing joints

Piping Structure joints in the open deck- node joints

Heli Pad construction and Supporting TKY, I Beam joint inspection

Tank partition T joint, I beam joints

Elbow Joint and nozzle connectors

Perform and witness Liquid Penetrant Test, Magnetic Particle Testing, and Ultrasonic testing, Hardness Testing.

Performing NDT for all kinds of fabrication with various methods and techniques as applicable

Interpretations and evaluation as per codes and standards and reporting to clients.

Offshore experience working as NDT inspector.

Preparing and Maintaining the NDT reports and equipment.

Evaluate the defects as per ASME section V & client specifications.

Previous working profile

May 2005 to June 2007:

Employer : SIS NDT Inspection Services, Ashok nagar, Chennai

Position : NDT Inspector

Supplied to : PSL HOLDING PTE LTD, Gujarat, India.

Work Scope:

Evaluating Ultrasonic Examination in Pressure Parts as Well as A Non-Destructive

Parts, Boilers Drum Circems, Long seams, Tie Rod Scanning etc., & also Doing Special

Project Job Scanning like Heat Exchangers Cladding, Buttering & Valves Casting.

Carry out Ultrasonic Testing on Various types of Structures, Pipes and Plates

Preparing and Maintaining the NDT reports and equipments.

Conducting Lamination checking for plates

Inspection Magnetic Practical Examination in an Hand Cock Valves Production,

Header Circems, Long Seam in Dry Methods as Well as Wet method.

Preparing and Maintaining NDT Reports, Review Drawing & Specification and Modifying

FAMILIAR IN CODES LIKE:

AWS D1.1

ASME Sec V – Nondestructive Examination

ASME B 31.3

DNV-OS-C401

ABS

PERSONAL PARTICULARS

Date of Birth : 14th Sep 1984

Nationality : Indian

Permanent Address : Door No: 2/24, Sangothi Amman Koil St,

Karikattukkuppum. Muttukadu,

Kancheepuram Dist, Pin Code: 603112,

Tamilnadu, India.

Martial Stats : Married

Passport Number : G2749086

Place of Issue : Chennai, Tamilnadu, INDIA.

Date of Issue : 11 May 2007

Date of Expiry : 10 May 2017

Language Spoken : English &Tamil

DECLARATION

I here by declare that all the details furnished above are true to the best my knowledge

Thanking You.

Place: Chennai, India. Your’s sincerely,

Date: (M.Rajesh)