Resume

Sign in

Electrical Engineer Quality

Location:
Chennai, Tamil Nadu, India
Posted:
October 18, 2016

Contact this candidate

Resume:

Email ID: acw4j0@r.postjobfree.com

Mobile Number: 91-909*******

Total Experience: 5.1 Years.

Construction : Industrial, Residential,Commercial, Metro Rail,State and Central Government Projects.

Present Location: Chennai,India.

CAREER OBJECTIVE

To gain a position in a growth oriented organization that will support me to apply my knowledge, Technique and experienced in the field of construction of Industrial,Commercial,Residential and Government Projects in local and abroad while providing me with ample opportunity for the development of existing strength, skills and potential.

CARRER SUMMARY

More than 5 Years of overall experienced in the field of Construction like Industrial, Commercial,Residential and Government project (Metro Rail ). Strong advocacy with safety in obtaining a safe working environment. To join a progressive & reputable company as Professional to apply the relevant knowledge, expertise and experience acquired in previous employment and contribute significant progress. To implement fully the quality control procedure & inspection test plan in order to meet project specification requirement without causing delay to finish mile stones & HSE Concerning.

QUALIFICATIONS & COURSES :

Bachelor of Engineering (B.E-E.E.E) in ‘’Electrical ‘’ From Jun 2007-Apr 2011.

Oracle -Primevera p6 for Project Management.

Auto CAD.

PLC & SCADA .

SKILL / STRENGTH SUMMARY

Excellent exposure in Installation and Testing of Power Distribution Facilities, LV & HV Power Transformers from 33 Kv to 11 Kv,11kv to 433 v 630 KvA,11Kv to 415v 800 KvA

Excellent exposure Installation and Testing of LV & HV Dry type Transformer.

Excellent exposure in Installation of LV & HV Control Gear, Lighting Panel and Distribution Panel Board.

Excellent exposure in Installation and Testing of UPS and Stationary DC System and HVAC Electrical System.

Excellent exposure in Installation of Bus duct and BBT.

Excellent exposure in Installation and Testing of Grounding and Lightning Protection System.

Excellent exposure in Installation and Testing of LV & HV Cables and LV & HV Motors.

Exposure to Dimmer, Automatic Lighting and Sensors.

Good exposure to Spec. like NEC, IEC, NEMA & ASME.

Well Knowledge about Hazardous Area Classification like IP Rating, Explosion Proof Rating (Exd, Exe, Exi), Temperature Class, NEMA Rating.

PROFESSIONAL EXPERIENCES

1.Designation : Electrical In Charge – Planning & Projects .

Employer’s Name : ETA Engineering Private Limited.

Project : Chennai Metro Rail- Pachaiappa

Client : M/s CMRL

Location : Chennai, India.

Period : May 2015 to Present

Job Responsibilities:

Perform quality engineering review of design documentation for compliance with stated requirements, including vendor quality manuals and company quality records

Preparation of Project planning in primavera from start to end & monitoring its daily status to make sure the project in gain path .

In charge of the entire project, From client meeting to EB Ceig government approval.

Ensure that all electrical site activities are conducted under controlled conditions as per approved GFC drawings, Method of Statements and Procedure, Specifications and International Standards.

Conduct activities concerned with the quality control and quality assurance of Material receiving inspection of all Electrical Accessories, Equipments and Power and Control Cables like Conduits, Cable Tray, Grounding and Lightning Protection system,LV & HV Switchgear and It’s accessories, and It’s assembled parts, NGR, LV & HV Control-Gear Panel, Lighting Panel, Distribution Panel board, UPS and Stationary DC System, APFCR Panel, AMF Panel, LV & HV Motors, HVAC Panel, Lighting Fixtures and LV & HV Power Cables & It’s accessories like HV Termination-KIT, 3M-Cold Shrink Process Splicing Kit as per the project specification and Cmrl Specification.

Performed Witness Inspection of Testing and Pre-Commissioning of LV & HV Power Cables, Grounding and Lightning Protection system, LV & HV Control gear panel, Lighting Panel, Distribution Panel board, UPS & Stationary DC system, Annunciator Panel, Load Shedding Panel, LV & HV Motors, and Lighting Fixture as per the project requirements and vendor instruction manuals.

Witness Pre-commissioning for Energization and Testing.

Documents data obtained during all quality activities consistent with clients and company policies and procedures.

Participate in solving quality issues which been issued by client and coordinating to Engineering and Vendor regarding technical issue related to execution of work and material as per schedule.

Review and update Inspection Test Plan and Inspection Checklist as per Project Specification requirements for submission to client.

Prepares reports to communicate involvement and results of quality activities.

2.Designation : Electrical Engineer-Planning & Projects.

Employer’s Name : Eta Engineering Private Limited

Project : Pranna Resort

Client : M/s Aghl India

Location : Chennai, India

Period : May 2014-May 2015

Job Responsibilities:

Perform quality engineering review of design documentation for compliance with stated requirements, including vendor quality manuals and company quality records.

Ensure that all electrical site activities are conducted under controlled conditions as per approved GFC drawings, Method of Statements and Procedure, Specifications and International Standards.

Conducts activities concerned with the quality control and quality assurance of installation inspection of all Electrical Accessories, Equipment and Power & Control Cables like Conduits and Fittings, Cable Tray, Grounding System, Lighting Fixtures, Fire & Gas System, MCC Panel, LV & MV Motor and Power & Control Cable installation as per Project Specification.

Performed Witness Inspection of Testing and Pre-Commissioning of LV & HV Power Cables, Control Cables, Grounding System, Power Transformer up to 11 Kv /415v 630 Kva, MCC Panel and LV & MV Motor as per Project Specification and Vendor Instruction Manual.

Documents data obtained during all quality activities consistent with clients and company policies and procedures.

Attend Quality meetings with Client, Subcontractor and Construction team to discuss issues on work execution in line with quality.

Prepare reports to communicate involvement and results of quality activities.

Identification of Punch List Category and coordination of punch list closure.

Responsible for Punch List Clearing to ensure that the installation of all electrical equipments are completed and accepted by the Clients.

Maintain and Check Records of Lock-Out and Tag-Out (LOTO) of Energized and De-Energized Equipments and Circuits.

Attending weekly LOTO meeting with Client and Subcontractor.

Controlling all Electrical rooms which are energized and under LOTO.

Issuing daily basis work permit at all energized electrical rooms and maintains the Logbook of all Isolation and Access Permit inside the energized electrical rooms.

3.Designation : Electrical Engineer-Planning & Projects

Employer’s Name : Eta Engineering Private Limited

Project : Bosch Siemens India Private Limited –Industrial.

Client : M/s Bosch Siemens .

Location : Chennai,India

Period : Jul 2013-May 2014

Job Responsibilities:

Perform quality engineering review of design documentation for compliance with stated requirements, including vendor quality manuals and company quality records.

Ensure that all electrical site activities are conducted under controlled conditions as per approved IFC drawings, Method of Statements and Procedure, Specifications and International Standards.

Perform daily monitoring the testing and quality inspection activities. Monitoring the performance of work to ensure that contractor assign the appropriate resources to execute the work to required quality, standard and within the agreed schedule.

Manage documentation transfer for approval between contractor and company. Control of non-conformance and liaise with the Client and Sub-Contractor on all QAQC related issues.

Receiving MIR from Material Manager and Perform inspection of all loose Electrical, Instrumentation and Mechanical along with relevant accessories materials according to Purchase order, NMR and Client relevant specification and requirement.

Prior to start devices assembling, Perform inspection of all internal/ external electrical, electronic devices with appropriate rating, Volt, Ampere and Others necessary description as per the project specification.

Raising NCR against loses Electrical & Instrumentation and Mechanical Materials and Equipments which are not complying with project specification and requirements.

Conducts activities concerned with the quality control and quality assurance of Installation inspection of Electrical & Instrument equipments and Power & Control Cables like, Conduit, Cable Tray, Grounding System for Electrical and Mechanical Skid, Distribution Panel board, Lighting Fixtures and LV & MV Motors.

Performed the installation inspection of primary & secondary electrical and instruments cables, Cable dressing, Glanding & Termination at Instrument, Control Panel Side.

Performed Witness Inspection of Testing and Pre-Commissioning of LV & HV Power Cables, Grounding System, Distribution Panel board and Lighting Fixture as per the project requirements and vendor instruction manuals.

Performed witness inspection of Functional Test and Manual Simulation test of Distribution Panel and MCP.

Reviewing of all instrument accepted documents such as Instruments data-sheet, Vendor Drawings, P&ID, Quality control inspection reports signed by QC Inspector and Owner representatives.

Attend Quality meetings with Client, Subcontractor and Construction team to discuss issues on work execution in line with quality.

Prepare reports to communicate involvement and results of quality activities.

Identification of Punch List Category and coordination of punch list closure.

Responsible for Punch List Clearing to ensure that the installation of all electrical equipments are completed and accepted by the Clients.

Update the daily inspection reports and dispatch the punch list to the Construction engineer to rectify as per the project specification and Client requirements.

Responsible for the preparation of all inspection reports prior for the acceptance of the Client.

4.Designation : Electrical Engineer-Projects

Employer’s Name : ETA Engineering Private Limited.

Project : BOSCH India Private Limited-Industrial

Client : M/s Bosch

Location : Chennai,India.

Period : Jan 2013-Jul 2013.

Job Responsibilities:

Ensure that all Electrical and Instrumentation site activities are conducted under controlled condition as per approved IFC drawing, Method of Statements and Procedure, Project Specification and Standards.

Get the approval from the Client as per contract documents’’ Inspection Request’’.

Monitoring and Inspection of Construction works in progress to ensure compliance of materials and workmanship with design drawings and Specification.

Reporting and Documenting of Non-Conformance and Site observation in relation to quality.

Conduct activities concerned with the quality control and quality assurance of Installation inspection for Electrical equipments and Power & Control Cables like, Conduit, Cable Tray, Grounding and Lightning Protection system, LV & HV Control-Gear Panel, Lighting Panel, Distribution Panel board, UPS and Stationary DC System, LV & HV Motors, HVAC Panel, Fire & Gas System, Lighting Fixtures and LV & HV Power Cables as per the project specification.

Conduct activities concerned with the quality control and quality assurance of installation inspection for Instrumentation equipments and Instruments cables like Conduits, Cable Tray, Grounding System, Cable Trench and Routing, Control Panel, Consoles, FGS Panel and Junction Box and different types of valve.

Reviewing necessary drawing like, Instrument Layout Drawing, Loop Diagram, Fire and Gas Layout Drawing, Telecom Layout Drawing, Cable Schedule, Instruments/Cables Indexes and other pertinent drawings needed for inspection.

Performed Witness Inspection of Testing and Pre-Commissioning of LV & HV Power Cables, Grounding and Lightning Protection system, Metal enclosed bus-duct, LV & HV Switchgear, Power Transformer, LV & HV Control gear panel, Lighting Panel, Distribution Panel board, UPS & Stationary DC system, LV & HV Motors, HVAC Panel and Lighting Fixture as per the project requirements and vendor instruction manuals.

Witness Pre-commissioning for Energization and Testing.

Performed Witness Inspection of Testing and Pre-Commissioning of Primary & Secondary Instruments cables and impulse line tubing and Glanding & Termination from Instruments side to Junction Box & Control Panel side.

Prepare reports to communicate involvement and results of quality activities.

Identification of Punch List Category and coordination of punch list closure.

Responsible for Punch List Clearing to ensure that the installation of all electrical equipments are completed and accepted by the Clients.

Update the daily inspection reports and dispatch the punch list to the Construction engineer to rectify as per the project specification and Client requirements.

Responsible for the preparation of all inspection reports prior for the acceptance of the Client.

5.Designation : Electrical Engineer-Projects

Employer’s Name : Eta Engineering Private Limited.

Project : Daimler India Commercial Vehicles Private Limited-Industrial

Location : Chennai

Period : Aug 2011-Dec 2012

Job Responsibilities:

Ensure that all Electrical and Instrumentation site activities are conducted under controlled condition as per approved GFC drawing, Method of Statements and Procedure, Project Specification and Standards.

Conducts activities concerned with the quality control and quality assurance of Materials, Installation and Test by performing the following duties,

LV & HV Switchgear and Control gear Installation Inspection.

Electrical Distribution Panel board and Lighting Panel Installation Inspection.

LV & HV Motors and Power Cables Installation inspection.

Cable Tray and Conduit installation inspection.

Pre-Commissioning of Low Voltage and High Voltage Cables, Power Transformers, Switchgear, Controlgears, Lighting, Distribution Boards and Motors.

Documents data obtained during all Quality activities consistent with Client and Company Policies and Procedure.

Responsible for Punch List Clearing to ensure that the installation of all electrical equipments are completed and accepted by the Clients.

Preparation of Electrical QC Dossiers for Submission to the Client.

6.Designation : Graduate Engineer Trainee-(GET)

Employer’s Name : ETA Engineering Private Limited

Project : Nemak Aluminium Casting-Industrial.

Location : Chennai, India

Period : Jun 2011-Aug 2011

Job Responsibilities:

Man Power Distribution, Supervision and Control for the following;

Installation of LV & MV Cables as per cable schedule and GFC drawing for proper laying and dressing, route (Trench and Cable Tray).

Checking the installation of Motors, Distribution Panels, Switchgear as per approved GFC drawing and correct location and rating.

Installation of Plant grounding Network.

Arrangement of work permits, Equipments, Material Take-off and withdrawals

Coordinate to Quality Control Department and to other construction disciplines.

Conduct daily tool box meeting for the implementation of Safety and work related topics.

Report and Coordinate to Construction Superintendent for work progress and Planning of activities.

WORK REFERENCES

National Electrical Code NFPA70(NEC)

International Electrical Testing Association (NETA)

(Acceptance Testing Specification for Electric Power Distribution Equipment)

National Electrical Manufacturing Association (NEMA)

NEMA VE1 for Metal Cable Tray System

NEMAVE 2 for Cable Tray Installation Guidelines

NEMA 250 for Enclosure of Electrical Equipments 1000V maximum

NEMA RN1 for PVC externally coated Galvanized Rigid Steel Conduits.

NEMA TC2 for Electrical PVC Conduits

NEMA TC6 & TC8 for PVC Plastic Utilities Ducts for Underground Installation

NEMA MG1 for Motors and Generators

International Electro-Technical Commission (IEC)

IEC60529 for Classification of Degree of Protection Provided by Enclosure

IEC60227 for PVC Insulated Cables of Rated voltages up to 450/750V

IEC60502 for Power Cables of Rated Voltages 1KV up to 30 KV

IEC60840 for Power Cable extruded insulation 30KV up to 150KV

IEC60079 for Electrical Apparatus for Explosive Gas

IEC60076 for Power Transformer

Institute of Electrical and Electronic Engineering (IEEE)

IEEE 80 Guides for Safety AC Substation Grounding

IEEE 81 Guides for Measuring Resistivity, Impedance, Potential of Grounding System

IEEE 142 Recommended Practices for Grounding of Industrial Power System

PERSONAL INFORMATION

Father’s Name : S.Abdullah

Date of Birth : 12th April 1990

Marital Status : Un Married

Nationality : Indian

Language Known : English, Urdu, Hindi, Tamil.

Computer Knowledge : MS-Office (Word, Excel, Power Point & Outlook), Ms Primavera P6.

PASSPORT DETAILS

Passport No : J3091494

Issue at : Chennai, India

Issue On : 24TH Dec. 2010

Valid Up to : 23rd Dec. 2020

INDIA LICENSE

License Number : TN22 201********

Issue At : Chennai, Tamil Nadu.

Issue On : 23rd Mar 2013

Valid Up to : 15th Mar 2033

DECLARATION:

I hereby declare that the above statements and details given are true and correct to the best of my knowledge and belief. If an opportunity is given to me to serve in your esteemed concern, I will do my duties to the best of my abilities & experiences.

(A.ALI AHMED)



Contact this candidate