B.SEBASTIAN RAJ E-mail ID: acw2cp@r.postjobfree.com

S/o MR.T.A.BILAVENDARARAJ. Mobile: +91-909*******

*/**, *** ****** *************** Extension,

Guindy, Chennai-32.

Tamil Nadu,

India.

PROFESSIONAL OBJECTIVE:

To be a dedicated Team Member and use my skills and Knowledge for the growth of the organization that i work for. I have known my hard work and any employer who chooses to use my services will be glad to have done so.

Institution

Qualification

Year of passing

Percentage

Trichy Engineering College (Affiliated to Anna University)

B.E., (EEE)

2012

72.38%

Maruthi Polytechnic College

Diploma(EEE)

2009

74.83%

R.C.Hr.Sec.School

SSLC

2006

52.6%

WOKING EXPERIENCE:

I. Company : A.M.K Metal Industry in Trichy

Designation : Electrical supervisor

Duration : From July 2009 – Dec 2014.

II. Company : Thrisha Electrical & Engineering in Trichy (EA 2644)

Sub contract of AVB Teknosolves in Coimbatore under the

Contract of TANGEDCO...

Designation : Electrical supervisor

Duration : From Jan 2015 to Aug 2015.

III. Company : T&C Engineers Pvt. Ltd.

Under the contract of Greater Chennai Corporation

RIPON BUILDING AMMA MALIGAI...

Designation : Electrical supervisor

Duration : From Sep 2015 to Sep 2016.

AREA OF WORK:

11 KV TNEB RMU Panel, 11KV HT3Panel, Oil type 3 phase 11/0.433KV, 2x1000 KVA, 500 KVA Transformer with OLTC, RTCC and Harmonic filter, 1010 KVA Powerica Diesel Generator set with Exhaust.

Cubic floor mounting type Main LV Panel for Transformer control 2x1600A, 4P, ACB, EDO, 50KA for 1 second, DG control 1600A, 4P, ACB, EDO, 50KA for 1 second and bus coupler panel income 415 volts, 2x1600A, 4P, ACB EDO 50KA for 1 second, outgoing 2x1600A TPN 50KA MDO ACB, 8x800A TPN MCCB, 16x400A TPN MCCB & 5x250A TPN MCCB.

Cubical floor mounting type APFC 2x300 KVAR contactor controlled, utility panel-1, 415V 800A Alu bus bar I/C and O/G, utility panel-2, 415V 250A Alu bus bar I/C and O/G, MCC panel (plumbing) 415V, 125A Alu bus bar I/C and O/G.

Sub distribution panels with Alu Bus bar SSB- B&T I/C 2x125A FSU, O/G – 4x63A TPN, SSB-G, 1, 2, 3, 4 & 5 T I/C -2x125A FSU, O/G – 6x63A TPN, AHU SSB-G, 1, 2, 3, 4 & 5 T, I/C-2x125A FSU, O/G-6x32A TPN, UPS Incoming panel I/C-2x1600A TP2N ACB O/G-3x800A TP2N, 3x125A TP2N.

Sub distribution panels with Alu.bus bar UPS synchronizing and outgoing panel I/C -2x800A TP2N MCCB O/G-3x800A TP2N-3x125A TP2N, UPS SSB-G,1,2,3,4,&5 I/C-2x250A TP2N MCCB, O/G-6x125A TP2N MCCB, LIFT PANEL I/C-2x250A FSU, O/G-6x63A TPN FSU.

Indoor sandwich Alu bus duct outgoing 800A TPN rising mains for UPSRM’s, O/G 2x [12x250A TP2N 35KA MCCB], 630A TPN rising main for LPRM’s 1&2, O/G 2 x [16x 125A TPN 35KA MCCB], 400A TPN rising mains for AHU RM’s 1&2, O/G 2 x [12x 125A TP2N 35KA MCCB].

Maintenance of MOTOR CONTROLER CENTER 1 & 2, Adoptor panel, 3KW DOL starter, 2.25KW DOL starter, 0.75KW DOL starter, 4KW DOL starter, 15KW star delta starter.

2 x 400KVA, 415V Numeric UPS System, 80KVA, 415V Emersion UPS System.

Maintenance of CRI Sewage submersible pumps 2 x [1.50 KW, 2.0HP], TEXMO submersible mono block 7.5 KW, 10 HP induction motor, GRUNDFOS motor 9 x [18.5KW, 25HP].

Earth test links, supply, installation, testing and commissioning of multi points or taper points lighting protections air terminals.

Outstanding ability to read and update electrical drawing preparations, Schematics using AutoCAD.

Erection & commissioning of all electrical equipment’s Gladding cable jointing, control panel wiring and oil testing. Ability to handle extra high tension voltage, High tension voltage and low tension voltage.

Maintenance of Server room, Data center, OTIS lifts and JOHNSON lifts.

HVAC:

3 x 175 TR water cooling chiller complete with hermetic screw compressor, air separator with pressure tank capacity 100ltrs, link size 200mm, single cell, counter flow INDUCED DRAFT FRP COOLING TOWER for air conditioning system.

CHILLER WATER SYSTEM: chiller water pumps (primary); back pull out type centrifugal water pump complete capacity: 420 usgpm@35m head. : Chiller water pumps (secondary); back pull out type centrifugal water pump complete capacity: 420 usgpm@45m head. : Chiller water pumps (secondary); back pull out type centrifugal water pump complete capacity: 525 usgpm@35m head.

Air distribution system double skin treated air handling unit 415V+/10%V 50Hz 3phase AC supply 16TR 5473 CFM, 2 x 24.5 TR, 7510 CFM, 3 x 18 TR, 6434 CFM, 3 x 19 TR, 6524 CFM, 21TR, 7325 CFM, 23TR, 7908 CFM (25mm WC external static pressure), CEILING SUSPENDED UNIT 19 x 6TR & 4TR.

TREATED FRESH AIR UNIT double skin thermal floor mounting type 93TR, 31016 CFM WC external static pressure.

Maintenance of Air distribution system, Fire damper, Exhaust air valve, ventilation toilet exhaust fans. AC drain water pipe line.

Maintain & Operate For “Variable Frequency Drive” (VFD), “Variable Air Volume” ( VAV),“Heat Recovery Unit”(HRU), “Variable Refrigerant Flow”(VRF), 2x10 TR Precision Air Cooler”(PAC), Cassette AC, 16.5 TR Ductable AC, 2X100 TR Air Cooled Chiller unit, ”Damper Actuator”.

FIRE FIGHTING & ALARM SYSTEM:

Maintenance of fire alarm system [NOTIFY-NFS-640], VESDA, DDC panel, Gas releaser panel, water leakage detector (WLD), access control system, Ultrasonic rodent detector, closed circuit TV (CCTV), fire damper and flow switch.

Maintenance of kirlosker engine 4R1040TA 77.3 KW, 10 HP Governing class M2 with pump USM 100/36, I/P - 53.22 KW.

Maintenance of 3 phase induction hydrand motor 55 KW, 75 HP with pump DSM 100/36, I/P - 44.05 KW Delta connections.

Maintenance of 3 phase induction springular motor 55 KW, 75 HP with pump NSM 100/36, I/P - 44.05 KW Delta connections.

Maintenance of 3 phase induction Jockey motor 9.3 KW, 12.5 HP with pump CPHM 25/26 A, I/P – 7.83KW Delta connection.

Fire pipes, hose & FM 200, cylinders, springular, hydrand pressure maintaining.

PA SYSTEM:

Maintenance and operation of AHUJA & SHURE systems.

Good ability to set up all equipment’s for scheduled live events.

Excellent trouble shooting service and repair skills.

Good understanding of amplifiers, miking & mixers systems.

Extensive knowledge of lighting system audio and video components.

Able to work independently supervision and strong technical abilities.

RESPONSIBILITIES:

Building Management System.

Environmental health and safety regulations

Arrange to help local authorities for inspection.

Managing paper work for all commercial and office.

Manage projects to ensure any modifications are approved by clients.

Perform customer satisfaction follow-up reviews to improve services.

Proficient in working with the group and deliver the result on time.

periodic preventive maintenance & schedule activities

Close monitoring and analysis of power, fuel, water consumption

Attending HT & LT breaker breakdown & co-ordinate with service team

Monthly management report preparing and submitting (EB, DG, HVAC, FIREFIGHTING).

Preparing of AMC vendor tracking check list

Equipment’s history card maintaining

Maintaining power factor & Maximum demand.

Spare’s planning & monitoring daily requirement.

Creativity to Reduce the Power Consumption

52 week PM preparing & implementing.

Schedule the PPM Activities of Each and Every Week.

Lift passenger evacuation in case of lift stuck between floors

LOTO implementing & following.

TECHNICAL SKILLS:

Additional Training: Electrical Testing, Electrical CADD and PRIMAVERA.

Operating Systems: Windows 98, Windows XP/windows 7 & 8.

Languages known: C and C++ Basics.

MS Office: Word, Excel and Power point.

SOFT SKILLS:

Planning and Organization

Taking Initiative

Fast learner.

TRAININGS:

Attended a In-plant training in "Central Electrical Repair Shop" at Neyveli Lignite Corporation Limited. Neyveli.

Attended a In-plant training in "Vocational Training on Telecom Technologies" at Bharat Sanchar Nigam Limited. Trichy.

Attended a Project training in "Thermal Power Station-I" at Neyveli Lignite Corporation Limited. Neyveli.

Attended a Technical training in “Electrical testing on Insulation materials, PVC Cables & Domestic Appliances as per National / International standards” at Shriram Institute for Industrial Research. Bangalore.

Participated in a National level workshop on "PCB Design for mic Applications" organized by Shri Angalamman College of Engineering and Technologies. Trichy.

Participated in a National level working model contest on "DISTRIBUTED FACTS- A NEW CONCEPT ABOUT REALIZING GRID POWER FLOW CONTROL" organized by K.K.wagh institute of Engineering Education and Research, in association with IET. Mumbai.

Participated in a Technical Seminar on "EARTHING SYSTEMS" organized by Tamil Nadu Electrical Installation Engineers Association ‘A’ Grade. Chennai.

FINAL YEAR PROJECT:

PROJECT : DIPLOMA (EEE)

TOPIC : ADVANCED E.B AUTOMATION SYSTEM

PROJECT : B.E (EEE)

TOPIC : DISTRIBUTED FACTS- A NEW CONCEPT ABOUT REALIZING GRID POWER FLOW CONTROL

PERSONAL DETAILS:

Name : B.SEBASTIAN RAJ

Father’s Name : MR.T.A.BILAVENDARA RAJ

Mother’s Name : B.RITHA MICHEAL

DOB : 26/04/1989

Age : 27 years

Sex : Male

Marital Status : Married

Nationality : Indian

Mother tongue : Tamil

Permanent Address : HC-243, Anna Nagar 1st stop, Trichy-620026.

Present Address : 7/11, 1st street Narasinghapuram Extension, Guindy, Chennai-32.

Contact number : +91-909*******.

Languages known : Tamil, English.

C License No : C 46963

Passport No : L7739017

Driving.L.No : TN45 201********. Badge No: TN81 0000033

DECLARATION:

I request your utmost clemency to kindly select me and I assure you I will discharge my duties to the entire satisfaction of all my superiors.

Place: Chennai. Your’s faithfully,

Date: (B.SEBASTIAN RAJ)