Post Job Free
Sign in

17.2 Yrs experience in refinery,petrochemicals,plant commissioning etc

Location:
United Arab Emirates
Posted:
June 16, 2016

Contact this candidate

Resume:

CURRICULUM VITAE

Kishorkumar M. Patel,

Hydrocracker unit,

Takreer Oil Refining Company (ADNOC - Group),

P.O. Box-11885,

Ruwais, ABU DHABI, UAE.

M: +971-*********

O: +971-******** Passport No: H-3331509.

E-mail ID: ******@*****.**.**

INDUSTRIAL EXPERIENCE: 17.2 Years

Sub : Application for the post of SUITABLE POST

PRESENT & PREVIOUS EMPLOYER:

* At present I am working in TAKREER OIL REFINING COMPANY. ADNOC (RUWAIS Refinery division) since 30th OCT-2012 in operation

* At present I am working in RELIANCE INDUSTRIES LTD. Jamnagar (Refinery division) since 21st AUG-2006 in operation as EXECUTIVE.

* Previously I am working with PI INDUSTRIES LTD for 4.7 years as Production Supervisor from 28th dec-2001 to 19th –Aug.-2006 in OPERATION.

* Previously I am working with ACME PETROCHEMICAL LTD for 1.8 years as Plant Operator from 10th Apr.-1999 to 07th –Dec.-2001 in OPERATION.

EDUCATIONAL QUALIFICATION:

Bachlor of Science [Chemistry] passed in year April- 1999 from Saurashtra university with First class ( 60% )

ROLE AND RESPONSIBILITIES:

Deep knowledge of handling of various types of compressors, pumps, valves & handling of all types of hydrocarbons etc.

Safe Work Permit system and job hazard analysis.

Safety procedure awareness.

Preparation of standard operating procedure and follow-up.

Co-ordination with Pannel operator, shift engineers, shift-in charge, support services and other relevant department.

Monitor plant parameters like level, temperature, pressure, flow etc. and maintain log sheets – checklists.

Routine Sampling at plant requirement.

Handling and transferring of products and raw materials with different types and capacities of the pumps with safe manner and as per SOP.

Equipment’s positive isolation, venting and purging for maintenance activities.

Refinery Fuel gas system, Hydrogen Compressor unit ( 13.2 M.W. ) Four Stage Receprocating Compressor.

Different types of checklist maintaining as per norms of ISO-9001 and 14001.

Periodic inspection of LEL meter, O2 meter, H2S meter, Online BA set, SCBA set & other safety equipment device.

I was involved in Hydro testing, Cardboard blasting, Flushing, Purging and Cooling down of the pipelines.

I actively worked in Erection, p&id checking & prestart-up safety review, Pre-commissioning and commissioning of five HMU trand on RFG, LPG, Natural Gas, Neptha based.

I was totally involved in erection activities, which include FUEL GAS and HMU package construction checking as per P&ID and Designer’s documents. Plant normal shutdown & emergency shutdown.

PRESENT WORK PROFILE:

I have special operating experience in FIELD EXECUTIVE

Hydrogen Manufacturing Plant [05 Train], Cap. : 181 MTD

Hydrogen compression Unit (13.2 MW 4 nos compressor)

Refinery Fuel Gas Distribution Unit

Sat/Unsat LPG Treating Plants, Cap. : 23000/75000 BPSD

MY JOB AND RESPONSIBILITIES IN STEADY PLANT ARE AS FOLLOWS

Continuous monitoring of throughput

Continuous vigilant in the panel by taking reading at regularly interval.

Note down DCS readings for cross check with FIELD. (i.e. LT/FT/PT etc.)

Maintain trip defeat register, log book & log sheet and ESD system

Continue monitoring the FIRE & GAS detection system

Pump & Compressor change over

Monitoring the smooth and safe operation of rotating equipment like pump, compressor fin-fan cooler, and ID/FD fan of heater, etc.

Lighting of burners using BMS, Burners change over, Taking Tube Skin Temperature

Various Field Tests for assessing plant performance like weathering H2s check with dragger tubes, Chloride checking, taking closed and open loop samples for laboratory testing.

Checking of firebox and burner flame pattern.

Ensuring all standby pumps are always in healthy and warm up condition.

Maintain the record for the future/past shut down job.

Ensuring strict compliance with safety procedure, work permit procedure.

Check lube oil/ seal system and oil level in reservoir in RFG compressor.

Following proper housekeeping to ensure clean and safe work area.

British Safety Council [BSC] checklists fill up periodically. & Safety Audit checking. Other job instructed by shift incharge and panel operator. .

I have started up/shutdown and handled emergencies several times successfully giving full regards to safe work practices.

VARIOUS EUIPMENTS HANDLED INCLUDE :

Top Fired Balanced Draft Reformer [Make: M/S Selas Fluid Processing Corp. USA] with 288 tubes & 84 burners. Heat duty of reformer is 195 MMKcal/hr.

Four stage Double acting Reciprocating compressors [Make: M/S Thomssen International BV, Nehterland] – 4 nos. of 13.2 MW each having capacity of 161,000 Nm3/hr for pure H2 supply to refinery.

Multistage Centrifugal LPG pump of 366KW rating [Make: Ingersoll Dresserrand]

.

Single casing two stage Centrifugal Compressor for RFG [Make: Demag Delaval] of 3.5 MW having capacity of 22 TPH of RFG.

Process Gas Boilers & Steam Generator [Make : M/S Sruthers, USA] both combine capacity to produce HP Steam to tune of 130 T/Hr @ 44.0 kg/cm2 pressure & temp 392 C.

Pressure Swing Adsorption System. The flow rate through this system is 1, 20, 000 NM3/hr. of Reformate gas.

Flue Gas Blower [ID Fan] Cap. : 260000 kg/hr, Combustion Air Blower [FD Fan] Cap. : 19400kg/hr, [Make: Howden]

I have deep knowledge about safety equipment of PPE’s, LEL detector, SCBA set, FM200 system, water sprinkling system & deluge valve (DV’s) used during emergency.

PERSONAL DETAIL:

Permanent Address. At: Pajod. Ta: Manavadar.

Di: Junagadh. Pin. - 362620 (Gujarat)

Sex : Male

D.O.B : 11th Aug. 1978

Nationality : Indian

Height : 169 Cms.

Weight : 75 Kg.

Marital Status : Married.

TRAINING & ACHIEVEMENT:

Training for Basic FIRST AID, FIRE FIGHTING, 5S IMPLIMITATION, PPES, OHSAS, ISO-9001, ISO-14001, EMS, etc.

Having exposure to all safety equipment and instrument of F&G systemlikeFIREEXTINGUISHER,SCBASET,DGC,DGH,DFI,DMC, etc. training taken all for this.

Undergone various training modules designed by Reliance, Jamnagar covering all the Process Details/ Operational Training.permit system

Undergone FIRED HEATER WORKSHOP, FIRE & SAFETY and FIRST AID training imparted by Health Safety and Fire Dept. in Reliance Industries Ltd. at Jamnagar.

EMERGENCY HANDLED IN FOLLOWING CASES

1. Handled Emergency which was occurred hydrogen gas leakage

2. Reformer tubes failure

3. Chlorine gas leakage.

Date:

Place: Kishor M. Patel.



Contact this candidate