CV FOR SUBSTATION MAINTENANCE TECHNICIAN
MUHAMMAD KAMIL SHAHZAD
PERSONAL INFORMATION:
E-MAIL: *************.*******@*****.***
Cell # 009***********, 009***********
PERMANENT ADDRESS: House no 392/58 Saeedi street no 1 people colony
Mumtazabad Multan Pakistan.
DATE OF BIRTH: 21 August 1986
SEX: MALE
MARITAL STATUS: Married
PASSPORT No: KQ5141552 (Expiry date: 28-May-2017)
NATIONALITY: PAKISTANI
QUALIFICATION:
ACADEMIC: Matriculation with science 2000-2002.
TECHNICAL: Diploma of Associate Engineering Electrical Technology 2002-2005.
COMPUTER: 04 Months short course of MS-Office and Windows operating system.
CAREER OBJECTIVES:
I am searching for a good position of Substation/ Electrical Technician in a challenging and dynamic working environment. Where I can face new challenges day by day and I can best utilize my experience and knowledge.
EXPERIENCE SUMMARY:
Currently I am working as Senior technician in 5200 MW Ghazlan Power Plant with CG Power Solution Company. I am a young, dynamic, energetic and hard working technician with more than 8 years professional experience in maintenance and testing of various electrical equipment in Fertilizer Companies and Electricity Utilities Companies.
I am working since 2006 in different companies with different positions in maintenance of various electrical equipment like power transformers, motors, switchgears, Circuit Breakers, storage batteries and other equipment. I always accept the new challenges and choose the right method to solve the problem to reduce the time and cost and increase the production.
I am specialized in power transformers and circuit breakers. All the issues which are involved in power transformer such as: Installation, Testing and commission, Corrective and Preventive Maintenance overhauling and troubleshooting, replacement and transportation of power transformer. Maintenance and testing of On-Load tap changer. Familiar with IEC standards.
Able to read schematic drawings and implement troubleshooting on circuits.
Well familiar with HSE, Process Safety, PTWS and LOTO standards and having a strong knowledge of personal and plant safety.
I have Authorized Permit Receiver certificate from Saudi Electricity Company.
Excellent skills to develop and implement Preventive Maintenance and Corrective maintenance.
Detailed Experience:
GHAZLAN POWER PLANT (CG POWER SA) (sep, 2012 to Present).
Carries out Installation, Testing and Commissioning, Corrective and Preventive maintenance and overhauling of Power Transformer up to 865 MVA – 380/230/115/69/33/13.8KV.
Testing of Power Transformer like Turns ratio, Winding resistance, Insulation resistance, Tan-Delta, Polarization Index, Magnetic Balance test using Omicron and megger test equipment etc.
Relay coordination with main control room.
Maintenance and testing of On-Load tap changer (Diverter Switch).
Testing of buchol’z relay with nitrogen.
Preparation of different gaskets like Cork, NBR and O-Rings.
Vacuuming and under vacuum oil filling.
Operation of filtration machine independent.
Leakage arresting and changing gaskets.
Oil sampling for different tests like Dissolve Gas Analysis, Break down Voltage and Acidity test.
Maintenance of Metal Clad circuit breakers (Low-oil, Air and SF6) – 33/13.8/6.3/4.1 KV.
Testing of Circuit breaker like timing of contacts, contact resistance and Insulation Resistance.
Over hauling of circuit breaker mechanical mechanism.
Changing of capacitor in capacitor bank.
Troubleshooting and Maintenance of Motor Control Center (MCC).
Fault diagnosting and troubleshooting using schemetic drawings.
Testing and maintenance of motors.
Arranging Emergency power supply, diesel generators and distribution panels.
Planning maintenance procedures, list of tools, test equipment and material.
Testing, Termination and jointing of LV Cables.
SAUDI OGER LTD Saudi Arabia (Aug, 2009 to May 2012):
Maintenance of Distribution Transformers – 13.8KV/380V
Oil sampling and Break down Voltage Test of Oil.
Preventive and Corrective Maintenance of Air Circuit Breakers 13.8KV.
MV and LV cable jointing and termination, fault diagnosing and rectification.
Installation, commissioning and maintenance of distribution panels.
Troubleshooting of street lighting circuits.
Maintenance of batteries and battery chargers.
Pakistan Telecom Company Feb, 2008 to Aug 2009):
Testing, Preventive and corrective maintenance of transformers up to 6MVA.
Testing, Preventive and corrective maintenance of Air Circuit Breakers.
Preventive and corrective maintenance of Switchgear.
Rectifier Unit and storage batteries.
Cable lying, termination and jointing.
Maintenance and checking specific gravity of storage batteries.
FAUJI FERTILIZER COMPAY (Feb 2006 to Feb 2008):
Got Apprenticeship certificate for 02 years on following equipments.
Distribution Transformers up to 3MVA, 6.3KV/380V.
Metal-clad low oil and air circuit breakers 6.3KV.
Installation of Motor Control Panels.
Troubleshooting of motor control centre (MCC).
LV and MV motor testing, maintenance and greasing.
Testing, lying, jointing and termination of power and control cables.
Preventive maintenance of storage batteries.
Troubleshooting of lighting circuits.
PROJECTS:
Successfully finish the complete overhauling of power transformers 250 MVA-230/69KV, 167 MVA-230/69KV and 180 MVA-230/69KV with SEC Transmission (National Grid) department.
Installation, testing and commissioning of 06 numbers of Power Transformers (25 MVA) at SEC Power plant (Southern area).
Dismantling, Shifting, Reinstallation, Testing and commissioning of 7 No’s of transformers (5-30MVA-33/13.8KV) as a team leader on reinforcement project of SEC northern areas.
SAFETY:
I have good awareness about the personal and plant safety measures to complete the work safely and within time limit. I have good awareness about hazardous area and safety rules which should be followed in hazardous area. I am the certified receiver of work permit in Saudi Electricity Company.
I participated in following safety trainings.
Fire fighting training at Fauji Fertilizer Company Ltd safety department.
Work permit procedure and lock-out procedure training at Fauji Fertilizer Company Ltd safety department.
Work permit, lock out tag out (LOTO) and work permit receiver training at Saudi Aramco Safety Training department in KAUST.
Tool box meetings at Saudi Oger Ltd safety department.
Work permit and LOTO and work permit receiver training at Industrial Security and Safety department of Saudi Electricity Company.
Fire fighting training at Industrial Security and Safety department of Saudi Electricity Company.