Post Job Free
Sign in

Testing and commissioning engineer

Location:
India
Posted:
August 21, 2015

Contact this candidate

Resume:

JAYAPRAKASH V

Address: N.S nivas ambar kasaragod, Kerala India

Contact No: +919*********

Email Id: ***********.**@*****.***

Testing & commissioning engineer

“Strong analytical and technical knowledge in the field of testing and commissioning”

OBJECTIVE: Looking forward to an opportunity for working in a dynamic, challenging environment where I can utilize my skills and experience in the field of Testing and Commissioning of power system products, and Execution of projects related to power systems. Expertise in testing of Electrical power equipments,Strong knowledge on Electrical equipments.

Good hands on Experience in use of testing kits.

Proficient in interacting and coordinating with clients to collect the requirement.

Strong Domain Competency in switchyard and switchgear testing including GIS.

Quick learner and excellent team player, ability to meet tight deadlines and work under pressure

Possess sound development andcommunication (verbal and written) skills.

Energetic, enthusiastic and hardworking, result oriented team player inclined towards achieving career goals and enterprise objectives.

Involvement with the clients to make the required modification in the scheme.

Expose to tools:Omicron C256,AutoCAD,Tan Delta using Megger kit & Eltel,CPC 100

Academics

B.E. (Electrical & Electronics) Visvesvaraya TechnologicalUniversity (2012)

Career Summary

Experienced in 765kV, 400kV, 132 kV, switchyard H.T (upto 11kV) and L.T panels testing.

220Kv GIS testing & scheme checking.

Thorough in scheme checking.

Relay testing of Micom P120, P127, and P220.

Handling Tan-Delta (Eltel, Megger, Omicron CPC100) test kit Omicron C256 kit.

Handling CPC 100 Omicron Kit.

Professional Experience:

Having an experience of 2.7 years in Testing Commissioning and Maintenance of power plant, substation and process plant.

Job Title : Testing and Commissioning Engineer

Previous Employer : Voltech Engineers Pvt Ltd Chennai

Date of Joining: 04 October 2012

Maintenance of H.T & L.T Panels.

Created and Executed QA and testing process.

Experienced in Testing and Commissioning of765kV, 400kV, 132kV, 220KV switchyard AIS& GIS, H.T and L.T panels testing.

Thorough in scheme checking.

Relay testing of Micom P120, P127, and P220.

Handling Tan-Delta test kit Omicron Kit.

Handling CPC 100 Omicron Kit.

Maintenance experience of 6.6kV, 11kV, 415V Panels in CHP, Boiler, FOPH, ESP in a Thermal Power Plant (D.B Power super thermal power plant Baradarha, Chattisgarh).

Projects:

2x600MWD.B Power super thermal power plant Baradarha for L&T Ltd.

2x685MW GMR CHATTISGARH ENERGY LIMITED Tilda for SIEMENS Ltd.

100MW GAS BASED POWER PLANT NEEPCO LTD, MONARCHAK TRIPURA

1X165MW Blast furnace at BHUSHAN STEEL LTD Angul for SIEMENS LTD.

765/400kV Switchyard Power Grid Corporation of India Ltd at Sundargarh Jharsuguda Orissa, India for SIEMENS LTD.

33kV switchyard for Apollo hospital Raipur, Chattisgarh

400/220kV GIS Power Grid India LTD, Hamirpur HimachalPradesh for SIEMENS LTD.

220kV GIS Power Grid India LTD Gurgaon Haryana for SIEMENS LTD.

66kV GIS at SS-06 OPAL, DAHEG, BHARUCH, Gujarat for SIEMENS LTD

400/220/66KV GETCO Substation, Kosamba, Gujarat for SIEMENS LTD.

765/400/220 KV Power grid Corporation of India LTD, Fatehpuer,Uttar Pradesh for SIEMENS LTD

Skill Set:

Testing and commissioning of all Electrical equipment from 415 volts to 765 KV System.

Inspection of control and relay panel, preparation of Test Report and cable schedule for sub-station, power plant, and process plant.

Testing and commissioning of control & relay panel for Transformer, Bus Coupler and Line feeder.

Testing and commissioning of power control centre and motor control centre.

Testing of Protective Relays for various needs. Experience with relays.

Over current, earth fault relays, Motor protection relays.

Knowledge of Transformer protection, Transformer Differential Protection & REF Protection, Bus Bar protection, and synchronizing scheme.

Operation and Maintenance of Power Plant and sub-station.

Trouble shooting of all Electrical circuits, control and protection circuits

Co-ordination with client in As Built Scheme drawing submission, test report submission,

As build cable schedule submission and all site activity to satisfy the customer.

Hands on experience in Testing and Commissioning of HT Motors up to 18MW

Hands on experience in Testing and Commissioning of LT Motors up to 140KW

Hands on experience in Testing and Commissioning of HT Power Cables up to 33KV

Testing of Power Transformers up to 80 MVA, OLTC, RTCC schemes,and Transformer protection schemes-Differential Sensitivity-Stability, REF Sensitivity-Stability, various protections tripping, interlocks.

Commissioning experience in various conveyer(Belt, Boom, Reversible shuttle)

Commissioning experience in crusher, Luffing Stacker, Bucket Wheel Reclaimer

Experience in conveyer protection pull chord, belt Sway, Zero speed protection

Experience in PLC DI,DO Checking and VFD drive, FLAP GATE commissioning,Motor Temp RTD,BTD .

Experience with ALSTOM RELAYS

P630 – Transformer Diff. Protection

Micom127- Directional O/C & E/F Protection

Micom121,111 O/C & E/F Protection

Experience with ABB Relays

REF 615- Feeder protection

REM 615-Motor Protection

RET 615- Transformer Protection

Trainings and Certifications

Training on AutoCAD 2012.

Personal Particulars

Date of Birth: 31August 1990

Passport No.: k3964559

Languages Known: English, Hindi, Kannada, Tamil, Malayalam and Tulu

Tools

Omicron C256

Tan-delta using Megger kit, Eltel kit, CPC100

AutoCAD 2012

Relay testing

Omicron CPC 100, CPTD1.

I hereby declare that the information given above is true to the best of my knowledge and belief.

Name: Jayaprakash V



Contact this candidate