Sidney O. White, II
Letter **** Anita Drive
of Intent Parma Heights, Ohio 44130
***********@***.***
Please accept this letter and the enclosed resume as my
? expressed interest in securing a position with your corporation
in a capacity that will most effectively utilize my specialized
skills, formal training and certification, and extensive
I am seeking experience in all facets of quality control inspection and
a role in an non-destructive testing.
environment
that As my resume reflects, I have built a solid foundation in my
encourages chosen field not only through my role a Certified
independent Non-Destructive Test Level II Inspector with a world leader in
decision-makin the design, manufacture, and integration of complex metal
g components and products, but also through my diverse and
and demands well-rounded experience as a Quality Control and Certified
both Non-Destructive Test Level II Inspector contracted for special
professionalis projects with corporations and power plants throughout the
m and country. As a professional inspector certified in various areas
flexibility. of testing, my years of experience encompass all facets of
performing Magnetic Particle, Radiographic, Visual, Mechanical,
? Dimensional, Liquid Penetrant, and Electrical inspections.
I am a disciplined, safety-oriented, highly-motivated
professional interested in exploring opportunities where I can
continue to utilize my experience, training, and talent to
contribute to the success of an established organization. I am
confident my diverse skills and proven experience would be an
asset to your team. I would welcome the opportunity to speak
with you, in person, to discuss my particular qualifications
and goals.
Thank you for your attention, consideration, and forthcoming
reply.
Sincerely,
Sidney O. White, II
Enclosure
Sidney O. White, II
Professional 6470 Anita Drive
Profile Parma Heights, Ohio 44130
page 1 of 3 ***********@***.***
Objective To secure a rewarding position where my extensive and diverse
experience in quality control inspection and nondestructive
testing, combined with my exceptional work ethic and commitment
to safety will be fully employed to deliver professional
results and desired outcomes.
Highlights
Professional background includes success, formal training,
well-rounded experience, and skills in:
?Quality Control Inspection and Nondestructive Testing:
?All facets of performing Magnetic Particle, Radiographic,
Visual, Mechanical, Dimensional, Liquid Penetrant, and
Credentials Electrical inspections for various environments and industries,
including: aerospace, defense, manufacturing, and nuclear power
plant construction and in-service/outage modifications
?Adherence to NAS-410 A.N.S.I, N45.2.6 ASME Section XI,
SNT-TC-1A Level II standards ?Familiarity with ASME, API, AWS,
ASTM, and 10 CFR 50
Experience ?Trained & certified in accordance with
NAS-410 A.N.S.I., N45.2.6 ASME Section XI, and SNT-TC-1A Level
II
?Liquid Penetrant Testing II Certified MAGNAFLUX CORPORATION
Hartford, Connecticut
?Magnetic Particle Testing II Certified MAGNAFLUX CORPORATION
Hartford, Connecticut
?Radiographic Testing II Certified MAGNAFLUX CORPORATION
Boston, Massachusetts
?Visual Testing I-IV Certified EPRI JONES APPLIED RESEARCH
Charlotte, North Carolina
?Turbine Training MAGNAFLUX CORPORATION Minneapolis, Minnesota
?Remote Visual Training REACTORS INTERNALS Nine Mile #1
Team Industries
Wood River, Illinois? 2014
Certified MT & PT
Performed PT inspections on OD welds on bellows and MT on fan
blades for boiler drums
Wyman Gordon
Cleveland, Ohio ?2007-2013
Certified Non-Destructive Test Level II Inspector
Recruited by this global leader in the design, manufacture, and
integration of complex metal components and products to set up
and standardize equipment, conduct tests, interpret and
evaluate test for acceptance or rejection and document test
results.
? Perform repetitive types of magnetic particle or liquid
penetrant non-destructive tests of raw
forgings and finished products both in-process and during final
inspection.
? Develop written instructions from approved general procedures
by the responsible Level III
Inspector.
? Demonstrate knowledge of codes, standards, and other
contractual documents that control the
method utilized.
? Generate a Discrepancy Report if indications are rejectable.
? Apply inspection stamp as required.
? Ensure all inspections are in accordance with
Military-Standards (MIL-STD-410), National
Aerospace Standards (NAS-410), and CNDTQ.
Professional Sidney O. White, II
Profile 440-***-****
***********@***.***
page 2 of 3
Experience
continued Various Contracts
Cleveland, Ohio ?10+ years
Quality Control and Certified Non-Destructive Test Level II
Inspector
As a Certified Inspector in various specialized areas, embraced
the opportunity to utilize skills at a myriad of facilities on
a contractual basis. While assignments and environments were
diverse, was always ultimately responsible for consistently
demonstrating an ability to make independent decisions and
handle a great deal of autonomy while working as an integral
member of an organization's team. Throughout the years
assignments included:
?International Gear Company (12 months) ~ performed MT and PT
inprocess and final
Nital Etch inspections on McDonnell Douglass and Sikorsky
aerospace gears for
tempering and rehardening, as well as Rockwell readings for
case in core, and core in case.
?Kewaunee Nuclear Power Plant (2 months) ~ performed 79-14
walkdowns and inprocess
welding on modified supports and new installations. Assisted
with reactor internal
removal, manway removal and installation, RTD installation, and
torqueing of reactor
cooling pump.
?Nine Mile Point #1 Nuclear Power Plant (8 months) ~ performed
ISI inspections, VT 1
and 3 remote Visual Exams of reactor internals, V 2 system leak
exams, VT 3 and 4 exams
of installed supports.
?Grand Gulf Nuclear Power Plant (5 months) ~ performed
inspections on component
supports, including: hydraulic and mechanical snubbers, rigid
struts, and spring cans. In
addition, did routine inspections for preventative maintenance.
?Fort Calhoun Nuclear Power Plant (5 months) ~ for 3 months
during this nuclear power
plant's maintenance and refueling outage, performed inspections
of wire splicing, FHA
relays, switches, meggering, cable pulls and routing, torquing,
and grouting. In addition,
did inspections on welding of seismic supports, pumps, valves,
and breakers; performed
hydrostatic pressure testing. Contracted on a later date to
perform routine inspections on
inprocess welding, operability of breakers, and preventative
maintenance.
?Clinton Nuclear Power Plant (9 months) ~ as a result of
successfully finding the
locations of socket welds from various drawings and systems,
performing PT tests, and
accurately and thoroughly creating reports and sketches during
new construction, was
hired back to verify inspections of mechanical maintenance
activities on pumps, valves,
bolted connections, and hangers. Coordinated with startup on
hydros and pneumatic
testing. In addition, performed document review and documented
results of inspections on
appropriate forms.
?Bath County Pumped Storage Project (2 months) ~ worked in
underground tunnels
observing, inspecting, and documenting the drilling of holes.
Performed water tests to
determine their lugent values of each hole. Further, witnessed
the pressure grouting of the
holes at various P.S.I. grout ratios.
?Perry Nuclear Power Plant (15 months) ~ during new
construction of this nuclear power
plant, performed NDE on containment structure in compliance
with AWS and ASME
specifications. Contracted at a later date to perform first
line visual welding and
mechanical inspections of installations of pipe supports and
hangers and to verify
dimensions and documentation for the Field Hanger Report
Dimension Program.
Professional Sidney O. White, II
Profile 440-***-****
***********@***.***
page 3 of 3
?James A. Fitzpatrick Nuclear Power Plant (4 months) ~
Experience performed mechanical
continued verifications and inspections of RHR systems, Torus attached
piping, valves, pipe
supports, and Hilti bolt installations.
?Port St. Lucie Florida Nuclear Power Plant (8 months) ~
involved with Hot Operational
Test of the reactor and related systems. Read various prints and
prepared inspection
reports. Inspected pipe bends of all class piping; checked the
angle, ovality, and thickness
of bend; in addition, performed a PT on the bend area of the
pipe.
?Rancho Seco Nuclear Power Plant (2 months) ~ performed PT, VT,
and mechanical
level II inspections. Jumped generators to inspect generator
tubes. Verified torquing of
manways. Performed PT and VT on auxiliary feedwater lines.
Performed TMI
modification Hydros, torquing of riser to ring headers, and
visual inspection of hangers.
?Hanford #2 Nuclear Power Plant (12 months) ~ performed QC
inspections (NDE) and
Additional VT on weldments and fabrications, repair work, reviewing
Info documentation, surveillance,
walk downs, and thickness measurements with D-meter
specifications. Worked on all
systems in containment.
?San Onofre Nuclear Generating Station #1 (5 months) ~ during
maintenance outage of
this nuclear power plant, performed QC responsibilities under
subcontract to Westinghouse
during Tube Sleeving Project to the steam generators. Performed
remote visual inspections
utilizing video equipment during sleeve insert expansion, hard
rolling, and brazing.
Conducted receipt inspections and mandrel loading and
surveillance. Assisted in the
Documentation Control Center. Performed PT and VT inspections
inside the steam
generators for tube plugs.
?Peabody Testing (22 months) ~ performed outage inspections to
turbines and other related
components in fossil and nuclear power plants. Performed RT on
turbines and boiler
drums, field welds, nuclear submarines escape hatches, heavy
wall castings. Completed
NDE on engine parts, airplane parts, and control drive rods.
Professional & Personal Skills:
?Excellent work ethic. ?Dependable. ?Detail-oriented. ?Flexible.
?Able to prioritize and juggle numerous projects simultaneously
and follow through to their fruition. ?Self-starter. ?Excellent
verbal and written communication skills. ?Committed to exceed
client/corporate expectations. ?Safety-focused.
Other Experience:
Machine Set Up Specialist and Operator, KEYSTRONE THREADED
PRODUCTS
Personal Data:
?Interests: fishing, sports, and spending quality time with my
family. ?Willing to travel.