SUMMARY: My expertise lies in * key areas: E&I Engineering,

Project/Construction Management, Commissioning, Facility

Operations/Maintenance and Quality. I am available for extensive travel

with a preference for hardship locations.

PROFESSIONAL HISTORY:

Senior E&I Engineer Bechtel 03/2012-

Present

Royal Commission for Jubail & Yanbu Jubail Directorate Kingdom of Saudi

Arabia

Saudi Arabian Bechtel Company (SABCO)

Senior E&I Engineer responsible for designing and reviewing electrical,

instrumentation and telecommunication systems for Jubail 1&2 and Ras Al

Khair Industrial Municipalities. This operation is the largest civil

engineering project in the world. I was one of two engineers, selected and

approved by the royal commission, providing oversight and leadership in all

aspects of the instrumentation and control systems for the operation.

Jubail expansion project had an approved budget of US5.6Billion. Ras Al

Khair project had an approved budget of US2Billion. Reviewed and approved

designs specifying distribution systems, breakers, transformers, fiber

routing, Ethernet switch placement, PLC, RTU, Instrumentation and valving.

Specified complete BMS systems, hardware and services (lighting control,

HVAC, Access Control, Energy Management, Fire Alarm etc). Reviewed and

approved industrial SCADA, DCS and BMS systems and architectures.

Developed the instrumentation and control section for the Royal

Commission's engineering manual. Developed Royal Commission specifications

for instrumentation and control infrastructure. Reviewed and approved all

control methodologies for all industrial systems in the areas mentioned.

Directed and approved AE firm design efforts. Regularly interfaced with

project construction teams, Saudi Electric Company (SEC), Saudi

International Petrochemical Company (SIPCHEM), National Industrialization

Company (TASNEE), Saudi Arabian Fertilizer Company (SAFCO), Saudi Aramco,

Saudi Arabian Basic Industries Corporation (SABIC) and Saudi Water Company

(MARAFIQ).

Senior E&I Engineer Bechtel 01/2011-

04/2012

Pueblo Chemical Agent-Destruction Pilot Plant, Pueblo CO

Senior E&I Engineer responsible for designing Chemical Abatement systems at

the Pueblo Chemical Depot. Project estimated value $900M. Reviewed and

approved designs specifying DCS, PLC, 1000s of instrumentation and valving.

The system utilized Honeywell DCS, Rockwell RS500 and 5000 series equipment

and many skid mounted panel views. Reviewed and approved P&ID, Logic

Diagrams, SAMA Diagrams, DCS screen/instrument/alarm/reporting

configurations, instrumentation systems and valving. Responsible for

insuring conformance to design intent and expected system performance. Site

system owner for the InTool instrument management application. Responsible

for interpreting and applying codes and standards relating to customer

design requirements (NFPA, ISA, IEEE, Federal and State of Colorado).

Accepted a position with the Royal Commission of Saudi Arabia working for

Bechtel.

Sr. Quality Manager and E&I Engineer Fluor

08/2009-12/2010

LOGCAP IV Afghanistan

Senior Quality Manager and E&I Engineer, supporting one of the areas of

operation. Project estimated value $1B over life of contract. Reviewed and

approved contract compliance for the Theater Master Scope of Work. Services

included: water, power generation, electrical, grounding and bonding, DFAC,

MWR, POL, Showers/Latrines/Ablution, Vector, and all other required

operating base support services. Subject media expert for power generation,

grounding and bonding, and electrical systems. Reviewed and approved

commission/decommission of services via the LOTD process. Conducted site

quality surveillances. Liaised with the DCMA (Defense Contract Management

Agency), insuring sites were in compliance with PWS requirements. If sites

received corrective action requirements (CAR), was responsible for

resolving the deficiencies. Contract was completed. Accepted a position

with Bechtel.

Senior Construction Commissioning Engineer Fluor

03/2008-08/2009

Oak Grove Power Plant Oak Grove TX

Senior Construction E&I Commissioning Engineer for the Oak Grove Power

Plant. Project was valued at $2B and was named Power Plant of the Year by

Power Magazine 2010. Reviewed and approved overall testing and

commissioning plans. The system was comprised of two super critical 800MW,

coal-fired, GE Turbine, Alstom boiler, units. The control system was an

integration of Foxboro DCS, Rockwell Controls, GE Mark IV, Cimplicity and

thousands of instrumentation. Provided E&I technical expertise during

system start-up. Reviewed and approved the P&ID as-built, loop drawing and

logic diagram packages. Partnered with project and design engineering

resolving construction technical issues. Reviewed and approved factory

acceptance tests, O&M manuals submittals and spare parts requirements.

Reviewed and approved contractor/vendor warranties. Managed the turn over

process by defining turnover boundaries and providing turn over packages to

the client and DOE. Conducted periodic site inspections and issued quality

action notifications when deficient items were discovered. Developed and

maintained E&I punch lists. Provided technical expertise for the lessons

learned program. Conversant with the practices and procedures of

international design codes and standards relating to design and

construction. Recruited to Fluor Afghanistan.

Commissioning and E&I Engineer Tegron

09/2007-03/2008

Kinder Morgan LNG Compressor Stations Beaumont TX and Jennings LA

Freescale Facility Support Tempe AZ

Commissioning and E&I Engineer for Kinder Morgan Gas Systems in east Texas

and Louisiana. Kinder project was valued at $10M. Operations and E&I

contract engineer for Free Scale in Tempe Arizona. Freescale service

contract was ongoing and was valued at US250K. Responsible for generating

an overall testing and commissioning plan of the gas line distribution

system. Reviewed and approved testing and commissioning plans and

schedules. Reviewed and approved P&ID, loop drawings, logic diagrams, SAMA

diagrams, instrumentation selection and vendor warranties for as-built

packages. Provided support as a field engineer. Recruited to Fluor

E&I Engineer, Construction and Quality Engineer Intel

08/1991-09/2007

Intel Corporation Global Support

E&I Engineer and Quality Manager for Intel Global Fabrication facilities.

The systems were comprised of GE Cimplicity, Rockwell Software and PLCs, GE-

based PLCs, Johnson Controls and thousands of instrumentation. These

systems interfaced to chemical, cooling, heating, batch, logistic, building

management, high purity and bulk gas distribution systems and many complex

process equipment suites. Reviewed and approved design, engineering,

construction and OM methodologies for multiple facilities and retrofits.

E&I engineer for DCS/SCADA, PLC, instrumentation, Maximo and all backend

SQL data interfacing to other applications. Participated in the Intel

Global Joint Engineering team that reviewed and approved all global

infrastructure design packages for current and future copy exactly designs.

Reviewed and approved contractor's testing and commissioning plans and

schedules, factory acceptance tests, O&M manuals, spare parts listings and

training. E&I Intel manager of project sub-contractors. E&I Engineer that

developed Intel global power monitoring systems. Reviewed and approved all

designs involving power quality monitoring power re-start. Quality manager

providing oversight for Intel ISO 9000 certification for Global Facilities.

Intel representative that participated in ISO compliancy audits. Developed

Intel I&C training courses that were transferred to New Mexico's state

junior college. Additionally, I worked in the Intel Business Divisions,

specifically, the embedded and network processing divisions. I was selected

for my in depth knowledge of industrial control systems. As the technical

representative, my team was able to integrate Intel silicon into many of

these applications. Chose to leave as compensation was based on stock

options and Intel was no longer a growth company. Accepted a position with

Tegron.

Education and Certifications:

BSEE 1990 University of New Mexico

EIT 1995

2009 Maintenance Electrician - National Center for Construction Education

and Research

2008 DCS Engineer - Factory Trained Foxboro DCS Invensys Learning Center

DCS, PLC, Software and Communication Standards:

InTools, CAD, Foxboro DCS Invensys, Honeywell, ABB, GE Mark IV

RSControlLogix, RSCompactLogix, Micro Logix, SLC500, PLC5, Johnson Metasys,

Johnson DX series controllers, RSLogix 500 and 5000, RSNetWorx, RSLinx, GE

Cimplicity, GE9070 and 9040 series processors, Siemens, Foundation

Fieldbus, HART, Profibus, Modbus, Maximo, SQL, MS-Office productivity

software and many others.

Industrial, Commercial and LOGCAP Systems:

Power Plants, Process Control, Oil and Gas, Water distribution systems,

Industrial Waste Water, Sanitary Waste Water, Potable Water Distribution,

Water Purification, Desalination, Lift Stations, Chemical Abatement, Power

Distribution and Monitoring, Scrubbing Systems, Waste Water Treatment, Fly

Ash, Sorbent Injection, Flue Gas De-Sulfurization, Boiler Burner, Soot

Blower, Air heater, Coal Material Handling Systems, Gas Distribution

Systems, Scrubbers for Oil and Gas, Chillers, Cooling Towers, Foxboro DCS,

GE Mark IV, Rockwell, Siemens, Instrument Tagging and Alarming Systems,

Switch Gear, Sub-Stations, Turbine Control, VFDs, Power Restart, Make-Up

Air Systems, Air Circulation Systems, Building Automation, Lighting

Distribution and Control, Service Order system design, Work Desk

Operations.