SHAWN PARSONS C.E.T
Edmonton, Alberta
T6J 0J6
************.***@*****.***
PERSONAL SKILLS
Over ten years in QA/QC, Turnaround inspections, inspection planning
and refinery reliability tasks. Primary work involves inspections of
in-service pressure vessels and piping, Piping and vessel fabrication,
and structural fabrication and/or repair. Certified Engineering
Technologist in Alberta, Canada.
. Good knowledge of all local jurisdiction laws, codes, standards, and
regulations.
. Good knowledge of corrosion and welding, including: corrosion related
damage mechanisms, base metals, filler metals, heat treatment, welding
metallurgy, weld and corrosion testing, fabrication planning, and
welding repairs
. Developing, when necessary, multidiscipline Inspection and Test Plans
for Owner/Client specific requirements
. Strong support and direction to the Quality team and project teams as
required and support resolution of conflicts through effective
interface with the Area Managers,
. Assist with developing, implementing, and maintaining the pressure
vessel and piping inspection plan together with engineering and
corrosion specialist support.
. Strong desire to learn
. Able to work constructively as part of a team or individually
. Very capable with computers and learning new programs, efficient in
Microsoft operating programs Word, Excel, Powerpoint, and Outlook.
. Able to manage tasks in order to accomplish goals in a safe and
efficient manor
. Experience in fabrication, construction, and plant maintenance
environment
. Diverse knowledge of piping and vessel operations for oil and gas
plants
. Strong knowledge with ASME, API codes and ABSA requirements
. Prepare and issue NCR (Non Conformance Reports) resolve by developing
and implementing corrective measures
EDUCATION
. MATERIALS ENGINEERING TECHNOLOGY (N.A.I.T.)
V API 510 Pressure Vessel Inspector Cert # 36228
V API 570 Pressure Piping Certification Cert. # 65037
V CWB Visual Inspector Level II (ASME 31.3, Sec. VIII & IX) REG #
4504
V CWI Visual Inspector (American Welding Society) Cert # 01006007
V Magnetic Particle Inspection Level II (CGSB/ASNT) REG #
12138
V Liquid Penetrant Inspection Level II (CGSB/ASNT) REG #
12138
WORK EXPERIENCE/ HISTORY
Aug. 2014 - Present TIR Canada
QA Mechanical Supervisor
-Conoco Phillips, Surmont Phase 1
- Provide leadership and management to Quality Inspectors and Quality
Administrators
- Audit and review of construction turnover documentation from
contractors for welding and fabrication.
- Review and final acceptance in representation of Conoco Phillips on
turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA) for
fabrication, assembly, and repair
- Inspection and surveillance on welding and fabrication
- Coordinating and planning third party companies for NDE (EC, UT,
LPI, MPI, and RT)
- Witness hydro-testing and sensitive leak tests.
June. 2013 - June 2014 Aker Solutions (CNRL)
In-service Inspector
- Canadian Natural Resources Ltd, Horizon site.
- Perform inspection tasks and schedule monitoring programs to assure
the mechanical integrity of various types of pressure equipment
- Maintain permanent and progressive records of all pressure vessels
and pressure relieving devices, including adding new information
pertinent to the operation, inspection, and maintenance history of the
equipment
- QA inspections and report writing on pressure vessels (internally)
and pressure piping during shutdown.
- Review and final acceptance in representation of CNRL on turnover
packages with ITP's, AB-40 (ABSA), AB-83 (ABSA) for fabrication,
assembly, and repair
- Coordinating and planning third party companies for NDE (EC, UT,
LPI, MPI, and RT)
- Provide leadership and management to Quality Inspectors and Quality
Administrators
- witness hydro-testing and sensitive leak tests.
Aug. 2012 - June 2013 Aker Solutions (CNRL)
QA Planner
- Canadian Natural Resources Ltd, Horizon site.
- QA planning for 2013 Turnaround
- Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication, assembly, and repair
- Review all Welding Procedure Specifications and quality manuals from
shutdown contract companies in representation of CNRL
- Coordinating and planning third party companies for NDE (EC, UT,
LPI, MPI, and RT)
Jan. 2012 - July. 2012 Acuren
In-service inspector
- Imperial Oil, Strathcona Refinery, Edmonton, Alberta
- Area lead inspector for turnaround, on-stream inspection and
internal inspections for pressure equipment and piping.
- Perform inspection tasks and schedule monitoring programs to assure
the mechanical integrity of the equipment
- Maintain permanent and progressive records of all pressure vessels
and pressure relieving devices, including adding new information
pertinent to the operation, inspection, and maintenance history of the
equipment
- Inspection and surveillance on welding and fabrication, as well as
auditing turnover packages from contractors.
- Construct work packages and witness hydro-testing and sensitive leak
tests
Nov. 2011 - Dec. 2012 FT Services
Quality Control Inspector
-Nexen Long Lake, Fort Mcmurray, Alberta (Projects)
-Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication, assembly, and repair.
-Advise on all matters relating to inspection and quality control
through the front-end planning, construction, and turnover phases of
the project
-Visual inspection and weld mapping for piping and Vessel fabrication
or repair.
-Construct work packages and witness hydro-testing and sensitive leak
tests.
-Coordinating and planning third party companies for NDE, Hydro-
testing and Machining, to fulfill needs of client and ASME code
Sept. 2011 - Nov. 2011 Acuren
Quality Assurance Inspector
-Syncrude (ie. Exxon Mobil), Fort Mcmurray, Alberta (Shutdown)
-Visual inspection and report writing for piping and Vessel
fabrication or repair.
-Inspection and surveillance on welding and fabrication, as well as
auditing turnover packages from contractors.
-Performing MPI and LPI on Vessels, piping, and structural steel in
accordance with Syncrude, and ASME specifications.
-Ultrasonic thickness measurements on vessels and Piping for
corrosion/erosion monitoring and to establish remaining life.
Feb. 2011 - Jul. 2011 Acuren
Quality Assurance Inspector
-Suncor, Fort Mcmurray, Alberta (Maintenance In-service Inspector)
-Manage day-to-day operations with maintenance team to address any
concerns from engineers and operations in regards to all ABSA
registered equipment including rotating equipment, ASME piping,
Structural steel, and storage tanks.
- Area lead inspector for turnaround, on-stream inspection and
internal inspections for pressure equipment and piping.
-Advise on all matters relating to inspection and quality control
through the front-end planning, construction, and turnover phases of
the project
- Perform inspection tasks and schedule monitoring programs to assure
the mechanical integrity of the equipment
- Maintain permanent and progressive records of all pressure vessels
and pressure relieving devices, including adding new information
pertinent to the operation, inspection, and maintenance history of the
equipment
-Visual inspection and report writing for in-service equipment in
Sulfur Upgrading Plants.
-Inspection and surveillance on welding, hydro-testing and
fabrication, as well as auditing turnover packages from contractor
Flint-Transfield Services.
Oct. 2010 - Feb. 2011 Metalcare (CNRL)
Quality Assurance Inspector
-CNRL, Horizon site (Maintenance In-service Inspector)
- Area lead inspector for turnaround, on-stream inspection and
internal inspections for pressure equipment and piping.
- Perform inspection tasks and schedule monitoring programs to assure
the mechanical integrity of the equipment
- Maintain permanent and progressive records of all pressure vessels
and pressure relieving devices, including adding new information
pertinent to the operation, inspection, and maintenance history of the
equipment
-Visual inspection and report writing for in-service equipment in
Secondary Upgrading Plants.
-Inspection and surveillance on welding, hydro-testing and
fabrication, as well as auditing turnover packages from contractor.
-Manage day-to-day operations with maintenance team to address any
concerns from engineers and operations in regards to all equipment
including rotating equipment, ASME piping, Structural steel, and
storage tanks.
Nov. 2008 - Oct. 2010 Acuren
Quality Assurance Inspector
-Syncrude (ie. Exxon Mobil) Fort Mcmurray, Alberta
-Visual inspection and report writing for piping and Vessel
fabrication or repair.
-Inspection and surveillance on welding and fabrication, as well as
auditing turnover packages from contractors.
-Performing MPI and LPI on Vessels, piping, and structural steel in
accordance with Syncrude, and ASME specifications.
-Ultrasonic thickness measurements on vessels and Piping for
corrosion/erosion monitoring and to establish remaining life.
Aug. 2008 - Nov. 2008 Edmonton Exchanger
Quality Control Inspector
-Alberta Envirofuels, Edmonton, Alberta (SHUTDOWN)
-Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication, assembly, and repair.
-Visual inspection and weld mapping for piping and Vessel fabrication
or repair.
-Construct work packages and witness hydro-testing and sensitive leak
tests.
-Coordinating and planning third party companies for NDE, Hydro-
testing and Machining, to fulfill needs of client and ASME code.
Mar. 2008 - July 2008 MELLOY Industrial Services
Quality Control Inspector
-Dow Chemical, Lacombe, Alberta (SHUTDOWN)
-Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication, assembly, and repair.
-Visual inspection and weld mapping for piping and Vessel fabrication
or repair.
-Construct work packages and witness hydro-testing and sensitive leak
tests.
-Coordinating and planning third party companies for NDE, Hydro-
testing and Machining, to fulfill needs of client and ASME codes.
-Coordinate other QC inspector's work and responsibilities.
-Auditing of all documents and NDE reports.
Aug. 2007 - Dec. 2007 ACUREN
Quality Control Inspector (LEAD)
-Opti-Nexen, Fort Mcmurray, Alberta (Long Lake)
-Visual inspection and weld mapping for piping and vessel fabrication.
-Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication, assembly, and repair.
-Assisted with weld inspection and NDE mapping for turnover packages.
-Construct work packages for hydro-testing.
-Coordinate NDE for code compliance and review NDE reports.
May 2007 - Aug. 2007 ACUREN
Quality Control Inspector (LEAD)
-Suncor, Fort Mcmurray, Alberta
-Manage day-to-day operations with maintenance team to address any
concerns from engineers and operations in regards to all equipment
including rotating equipment, ASME pressure piping, Structural steel,
and storage tanks.
-Construct turnover packages with ITP's, AB-40 (ABSA), AB-83 (ABSA)
for fabrication and assembly.
-Visual inspection and weld mapping for piping and Vessel fabrication
or repair.
-Construct work packages and witness hydro-testing and sensitive leak
tests.
-Coordinating and planning third party companies for NDE, Hydro-
testing, to fulfill needs of client and code requirements.
Sept. 2006 - Mar. 2007 ACUREN
Quality Control Inspector (LEAD)
-CNRL, Horizon site
-Visual inspection and weld mapping for pressure piping fabrication or
repair.
-Assisted with weld and NDE mapping for turnover packages.
-Witness and document closure welds in lieu of hydro-testing.
-Construct work packages for hydro-testing.
-Coordinate NDE for client and code compliance, and reviewing NDE
report for compliance.
Feb. 2006 - Apr. 2006 KBR (Halliburton)
Quality Control Inspector
-Syncrude (8-2 Coker SHUTDOWN)
-Visual inspection and weld mapping for piping and vessel fabrication
and/or repair.
-Assisted with weld and NDE mapping for turnover packages.
-Construct work packages for hydro-testing.
Dec. 2005 - Jan. 2006 EDMONTON EXCHANGER
Quality Control Inspector
-Syncrude (Plant 22-1 SHUTDOWN)
-Visual inspection and weld mapping for pressure piping and structural
steel construction.
-Assisted with weld and NDE mapping for turnover packages for ASME
31.3 piping.
-Coordinating and planning third party companies for NDE, Hydro-
testing, hydraulic torques, and Machining to fulfill needs of client
and ASME codes.
Aug. 1999 - Dec. 2005 ACUREN
NDE Technician
-Fort McMurray (Syncrude, Petro-Canada, Suncor)
-Performed MPI, LPI, PMI and other various non-destructive and
destructive tests for various clients.
-Thoroughly involved in failure reporting and investigation.
-Development of exemplary communication skills and profound ability
to use computers.
-Developed a respect for the implications and responsibilities of work
being completed (e.g. Quality control, code compliance, environmental
impact, safety, and contract fulfillment).
COURSES
- First aid course, OSSA Fall arrest, Confined space training and
monitor, H2S awareness, Construction safety training system, Radiation
training and awareness, FLHA training, Personal gas monitor, JLG and
man-lift training.
REFERENCES
Upon Request