Alec R. Roque
Carlsbad, NM 88220
****.*****@*****.***
objective
Seeking a full-time position within a growing company in a Power Generation
environment where I may utilize my mechanical and electrical knowledge,
experience, and education to provide consistent high quality services.
SUMMARY OF certifications
10 hour OSHA Industry Training Certificate
Standard First Aid Certificate, includes CPR, AED
Various Generator Controls certification
Diesel Power Generation Certificate
education
Michigan Institute of Aviation and Technology, Canton, MI
February 2010 - December 2010
Power Generation Technician Diploma
Tools and Safety
Lifting and Rigging
DC/AC Electrical Operation
Basic PLC and Ladder Programming
Turbine Engine Operation & Design
Maintenance and Overhaul
Electrical System Protection & Distribution
Hydraulic Fundamentals & Operation
Lubrication Systems & Cooling
Gear Systems Operation & Design
Wayne State University, Detroit, MI August 1990 -
December 1995
B.S. Computer Science
Work experience
Cummins Rocky Mountain, Hobbs, NM March 2013 -
Present
Remote Field Service Technician
Provide services by troubleshooting mechanical equipment for oil and
natural gas producing customers in Southeastern New Mexico. Diagnose and
repair generator set systems in a field environment without direct
supervision. Troubleshoot, diagnose, and perform repairs on voltages up to
600V on generators from 4KW to 2000KW. Complete understanding of single and
three phase AC electrical voltage and NFPA safety standard. Proficient in
troubleshooting, diagnosing and repairing emergency power systems and
related mechanical and electrical components. Possess the troubleshooting,
diagnosing and repair capabilities or a highly-skilled technician
involving diesel engine, generator, engine governor, generator and engine
control gear and electrical power switching mechanisms and their control.
Self-starter and readily adapts to changing work environment and work
assignments. Excellent in communication, report writing and team work
skills. Communicate and plan with customer to perform Start-ups, generator
commissioning and Preventative Maintenance on generator systems.
Cummins NPower, LLC White Bear Lake, MN March 2012 - March
2013
Field Service Power Generation Technician
Completed all maintenance procedures on diesel and gas generator sets
ranging from 30KW to 2000KW, including repairs to wiring harnesses,
alternators, solenoids, engines components, relays and electronic
components. Troubleshoot problems and faults on different types of
manufactured Automatic Transfer Switches. Used diagnostic equipment to
troubleshoot and repair diesel engines, generators, as well as AC/DC
circuits. Hands on experience with voltages up to 600 VAC. Maintained 100 %
accident free safety records until present by ensuring all maintenance
actions were performed in accordance with organization standard operating
procedures and OSHA standards. Conducted load analysis and balancing
ensuring constant power was delivered 24 hours a day to mission critical
equipment. Completed reports and parts requisitions ensuring all faults and
deficiencies were resolved. Comprehensive understanding of electricity,
electrical controls, generator sets and power distribution including safe
operation. Engine diagnosis and troubleshooting aptitude on diesel and
natural gas powered engines. Ability to read electrical wiring diagrams.
Ability to read instructions and communicate effectively.
DynCorp International, Kandahar, Afghanistan November 2011
- January 2012
Power Generator Mechanic
Supervise Power Generation Crew. Responsible for the operation and
maintenance of power generator single or multiple sets. Coordinate the
repair and replacement of components, generators, and sub-assemblies.
Coordinate with Electrical Shop and HSE in connecting power generation to
distribution panels/systems. Responsibilities include ordering replacement
parts. Coordinate generators and fuel tanks. Troubleshoot installations.
Kellogg, Brown and Root, B-1 Al Asad, IRAQ May 2011 -
October 2011
Power Generator Mechanic / Shop Safety Officer
Repair, rebuild and maintain various types of generators from 6KW to
1600KW. Generator types include Caterpillar, Cummins, F.G. Wilson, and
Whisperwatt. Responsible in executing the power generation program work
instructions on a site level. Ensure operational readiness on non-tactical
government property. Perform operation, maintenance and repair of power
production assets and distribution systems for Base Camp Facilities.
Perform a Load Bank Test on all generators prior to going on the ready line
or to the field. Implement Total Safety Task Instructions (TSTI) and along
with any associated Activity Hazard Analysis (AHA).
John E. Green Mechanical, Highland Park, MI September
2004 - June 2009
System Administrator/Fire Protection Designer
Help manage and supervise five branch offices and the corporate
headquarters, which included multi-platform environment that consists of
Novell and Windows servers. Responsibilities included maintaining,
troubleshooting, and configuration of servers, desktops, laptops, networks
and office equipment. Recommended, analyzed, and implemented system
enhancements and upgrades of hardware and software, provided support for
local and remote users, assist and perform backups, assist in ongoing IT
projects.
Northcomm / Pozicom Technologies, Lincoln Park, MI June 2003 -
August 2004
Commercial Satellite Installer / Network Administrator
Setup, configure and install commercial satellite dishes on roof of
buildings. Expose to the challenges in the job such as building heights and
confined spaces. Install necessary cable, electrical system and hardware.
Perform duties such as installing, connecting, disconnecting, and upgrading
cables. Provide technical support, upgrades of hardware and software, and
network solutions. Solutions involved Windows 2000, Netware 5.x and 6.x,
and Linux networks.
Davao Light & Power Company, Davao, Philippines
February 1998 - June 2003
Diesel Generator Mechanic
Responsible for performing quality, maintenance, diagnostics,
disassemblies, inspection, rebuilds and reassemblies of all components or
equipment, which includes engines, power trains, hydraulics, fuel system,
AC alternators either in the field or at the shop with or without
supervision. Types of generators include F.G. Wilson, Caterpillar, Detroit
Diesel, Volvo, Cummins, Perkins, Denyo and Mitsubishi. Diagnose electrical
issues to include 1 phase and 3 phase AC electricity and DC control
circuits. Diagnose machine faults using appropriate test equipment and
recommend repairs as required. Use Service and Parts information to
identify parts and procedures required to complete repairs. Troubleshoot
engine performance problems, make recommendation for repair, and create
estimates based on proper diagnosis repair or replacement. Work directly
with customers, order needed parts, coordinate efforts with various
vendors, suppliers, and manufacturers.