Post Job Free
Sign in

Electrical Engineer Power Plant

Location:
Caseros, Argentina
Posted:
April 22, 2014

Contact this candidate

Resume:

RESUME

Juan Emilio D’Amici

Personal Data

Surname: D’Amici

Name: Juan Emilio

Address: L N Alem 382 1A

B2800AVH – Zarate

Buenos Aires

Argentina

E-mail: ***********@*****.***; ********@*****.***

Telephone: 543*********

Mobile Phone: 542*********

Education

National University of La Plata (UNLP) – School of Engineering

Degree: Electrical Engineer

Entrance Date: March 1993

Graduation Date: March 2002

Academic grade-point average: 7.14

Academic grade in my major: 8.42

Work Experience

11-2008 up to present day

NA-SA, Nucleoeléctrica Argentina Sociedad Anónima

Atucha I Nuclear Power Plant

425 MVA Siemens Hydrogen cooled Turbo generator (21 kV)

1110 MWt Pressurized Heavy Water Reactor (Siemens)

Atucha II Nuclear Power Plant

838 MVA Siemens Hydrogen cooled Turbo generator (21 kV)

2500 MWt Pressurized Heavy Water Reactor (Siemens)

http://www.na-sa.com.ar/

Job:

Project and Maintenance Electrical Engineer

1

Experience:

Atucha I:

Project EPSS 2009 – present: Installation of the new Emergency Power

Supply System (EPSS) of the Atucha 1 Nuclear Power Plant. Three Siemens

Diesel Generator of 4900 kVA – 6,6 kV

General revision of the generator of the Hydraulic Turbine (Siemens 3900

kW – 6,6 kV air cooled, 700 rpm) during October/November 2009 ‘Stop’ of

the plant (General supervision by two specialists, one from AREVA and the

other from SIEMENS) .

General revision (ball bearings change and electrical testing) of induction

motor of the vapor system that low down the tritium content due to leakage

of it inside the reactor room (Siemens 12 kW – 0,4 kV)

General revision (ball bearings change and electrical testing) of induction

motor (Siemens 237 kW – 6,6 kV) of the oil-water refrigeration system of

the main step-up transformer

General revision (ball bearings change and electrical testing) of rotary

frequency converter that converts (Siemens 55 kW – 0,4 kV) the 50 Hz from

the power network into 250 Hz network that powers the blower motor of the

Reactor load machine

Implementation of the method RCM2 (Reliability Centered Maintenance 2)

with the Aladon Network license based on the book ‘Reliability Centered

Maintenance 2’ by John Moubray.

Rewinding inspection of the Reactor Auxiliary Refrigeration System induction

motor (Siemens 310 kW, 6,6 kV) at the Kolocsar workshop (technical

capacity to rewind motors and generators up to 25 MVA)

Collaboration on the general revision of the main generator (Siemens Turbo

generator 425 MVA-21 kV, hydrogen cooled) during the October/November

2009 ‘Stop’ of the plant. Main works: hydrogen seals change, rotor polish

and bearing rectification.

Supervision of the installation of the AREVA IED system for monitor power

transformers.

2

Supervision of repair works on the rotor of the hydraulic generator in the

MOTEC workshop (Machine data: Siemens, 3900 kVA, 6600 V, 342 A, 750

rpm)

Disassembly of the eight rotor poles and removal of the pole

o

windings.

Cleaning of the parts with dielectric solvent.

o

Drying in an oven with controlled temperature.

o

Impregnation in an autoclave without volatile solvent.

o

Control of the dielectric sheets to ground and replacement of the

o

ones which are deteriorated.

Assembly of the pole windings and the rotor poles and connections of

o

the windings.

Dielectric tests: resistance, insulation and surge test.

o

Atucha II:

General revision of all the induction motors of the Machine Room (bearings

change and electrical testing). Power range: 50 – 6000 kVA and voltage

range: 0,4; 6,6 and 13,2 kV

Induction motors electrical testing

01-2005 / 06-2008

Transener, Argentina (High Voltage Transmission Company that has 95%

of the Argentinean High Voltage System in 500 and 220 kV)

http://www.transener.com.ar

Job:

Substation Maintenance Engineer of the ‘Ezeiza’ 500 kV Substation (5000 MW of

power transmission and 2400 MW of power transformation (3 x 800 MW banks of

single-phase 500/220/13,2 kV transformers) and 6 x 125 MVA Synchronous

Compensators hydrogen cooled, the biggest substation in Argentinean Transmission

System)

Experience

MANTEC software operator (Maintenance Management Software). My work

relied on the adjustment of the Maintenance Inspection Sheets to the

Proceedings of the company.

3

Repair of the stator magnetic bore of the Synchronous Compensator number

2 due to a failure in January 2006. Description of the failure: Due to a failure

in a water pump the hydrogen overheated making one of the bolts of the

ventilation system take off, hitting the stator magnetic bores and causing

some damage to them.

Replacement of one the 800 MVA transformer banks in June of 2007.

Description: the replacement was made in two stages because the new

transformer bank was being made by ABB Brasil for November 2007. Then

we proceeded to modify the 500 kV substation to put in place two three-

phase transformer of 300 MVA each.

500 and 220 kV outdoor circuit breaker parameters measurement (BBC Air

Blast circuit breakers, Siemens SF6-Oil circuit breakers and ABB live tank

puffer SF6-Spring Stored Energy Mechanism).

02-2004 / 01-2005

Armanino Porcelain Argentinean Factory (FAPA) (the biggest porcelain

insulators factory in Argentina)

http://www.fapa.com.ar

Job:

High Voltage Laboratory Engineer

Experience:

High Voltage Laboratory description:

Facilities:

Impulse (with steep front) voltage generator.

Atmospheric impulse generator up to 1100 kV (1,2 / 50 µs) with positive

and negative waves.

Impulse current generator (8 / 20 µs).

Step-up Transformer 13,2 / 70-150-500 kV.

Facilities to perform electrical testing under water, controlled resistivity and

precipitation.

Facilities to perform dielectric strength testing in oil, 500 kV – 50 Hz.

Facilities to perform Radio interference testing (RIV measurements) IEC 437

- IRAM 2167.

4

Facilities for the determination of the voltage reference of OZn arresters.

Facilities to perform thermo mechanical behavior testing. Cycles of -30 C

and +40 C / ( 5 C) with mechanical traction loads. IEC 575 - IRAM 2369.

Facilities to perform aging tests under electrical strength (Salt fog and UV).

IRAM 2355 - IEC 1109 - CIGRE.

Facilities to perform tracking and erosion tests through inclined plane -

Norma IEC 587.

Facilities to measure the ball-and-socket joint for chain insulators - (cotter

pins) IEC 372 - 1/2 - IRAM 2249 - 1/2.

Facilities to perform electromechanical tests, 50 Hz - 250 kN.

Facilities to verify the porosity up to a pressure of 20 x 10 (6) N/m2.

Facilities to perform traction tests - 250 kN.

Facilities to perform flexion tests 50 kN and torsion tests 10 kNm.

Facilities to perform compression tests - 600 kN.

Facilities to perform rutinary traction tests to suspension insulators.

Facilities to perform rutinary electric tests with a continuous belt from only

one insulator to several ones together.

Heating facility by high current for bushings (5 kA).

Electric kiln with forced convection with graphic temperature and time

records (325 C).

Boiling facility to perform water diffusion test, IEC 1109 - IRAM 2355 -

CIGRE.

Facility to perform distance corona effect detection, directional and audible.

04-2003 / 01-2005 School of Engineering – National University of La Plata

(UNLP), Argentina

Teaching Assistant (Graduate Student) of the subject “Network Theory II”

http://www.ing.unlp.edu.ar/electrotecnia/tcii/

Experience:

Student guides for network synthesis based on the book ‘Network Synthesis’

by Van Valkenburg.

Synthesis of Z and Y matrix of LC chain networks with finite

transmission zeros.

Synthesis of RC impedance matrix and RL admittance matrix

of chain networks with finite transmission zeros.

Synthesis of RC admittance matrix and RL impedance matrix

of chain networks with finite transmission zeros.

Theory and practice class dictation: Bode diagrams and State variables.

5

Laplace transform laboratory: Aperiodic excitation transients (PSpice)

English – Spanish translation of the book ‘Linear signal. Flow graphs’ by

Etienne Cassignol and Yutze Chow

10-1999 / 04-2003 School of Engineering – National University of La Plata

(UNLP), Argentina

Teaching Assistant (Undergraduate Student) of the subject “Network Theory II”

06-1999 / 10-1999 School of Engineering – National University of La Plata

(UNLP), Argentina

Teaching Assistant (Ad-Honorem) of the subject “Network Theory II”

01-1994 / 12-1999 Argentinean Odontology Association

Collector

Cities: La Plata, Great La Plata, Berisso y Ensenada

Publication

Graduation Thesis (published on 27th March of 2002 by the library of

the Electrical Department of the School of Engineering – UNLP):

Algunos mecanismos de degradación de aisladores orgánicos (Some

mechanisms of degradation of organic insulators). Tutor Prof. Ing. Marcos

Deorsola: Professor of the subject ‘Network Theory I’ and researcher of the

institute IITREE-LAT School of Engineering, UNLP

Program used: Quick Field (Finite Element Program)

Languages and Computing

English: Writing: advanced; Speaking: advanced; Reading: advanced; Listening:

advanced

French: Writing: intermediate; Speaking: intermediate; Reading: intermediate;

Listening: intermediate

German: Writing: intermediate; Speaking: intermediate; Reading: intermediate;

Listening: intermediate.

MSOffice: Word, Excel, Power Point and Access.

AutoCAD: advanced

Management Software (MANTEC): advanced

MATLAB: advanced

Quick Field (Finite Element Program): advanced

6

ETAP: Experience using the Load Flow Analysis finding shunt capacitance

compensation in the node ‘Resistencia Substation 500 kV’ of the 500 kV Extra High

Voltage Argentinian Transmission System.

PSPICE: Orcad

SAP

Courses

GE’s Support Central Web based training:

Gas Turbine Fundamentals

o

Steam Turbine Fundamentals

o

Generator Fundamentals

o

High Voltage Shunt Capacity Compensation: application, design and

operation. CIGRE and the Technical Management of the Utilities during

insolvency

Integrated Management Systems. Applications of the standards ISO9001

and ISO14001.

Public security training and awareness. ENRE Resolution 057/2003.

Management training program by Transener.

Typewriting courses by Pitman Academies

References

Ing. Mario Coggio. Chief of the Department of Electrical Maintenance of the Atucha 1 & 2 Nuclear

Power Plants.

Tel. 54-348*-******. ******@**-**.***.**

Prof. Ing. Jorge Luis Agüero. Professor of the subject Network Theory II and Sub director of the

institute IITREE. School of Engineering - UNLP.

Tel. 54-221-*******. ***@******-****.***.**

Prof. Ing. Marcos Deorsola. Professor of the subject Network Theory I and researcher of the institute

IITREE. School of Engineering - UNLP.

Tel. 54-221-*******. *********@******-****.***.**

Prof. Ing. Gustavo Barbera. Assistant Professor of the subject Electro technical Materials and

Components and researcher of the institute IITREE. School of Engineering - UNLP.

Tel. 54-221-*******. ********@******-****.***.**

Hobbies

Tennis

Swimming

Music (Guitar)

Languages

7



Contact this candidate