W O R K EXPERIENCE IN INDUSTRIAL-X-RAY
Respected Sir,
I Sri Saroi Kumar Swain offer my candidature for NDT Coordinator and my entire work experience
certificate is attached with. Request you to state the following few lines for your kind consideration.
Name
Saroj Kumar Swain
Father's name Date of binh
Mr. Shyam swain 30th June 1973
Nationality Religion
Indian
Sex
Hindu
Marital status
Male
Married
Address for Plot No- AE-48, At- VSS Nagar, Po- Sahid Nagar,
communication Bhubaneswar, Khurda- 751007 Mobile-+964**********,
+919*********, +91-889*******, +91-943*******
At-Kuansol,Po-Bhagabanpur,Via-Lemalo Dist-Cuttack,P.s.-
Permanent Address Salipur,Orissa-754293 Mobile- +964**********,
+919*********, +91-889*******, +91-943*******
J8017389
Passport no.
03-06-2013
Date of Issue:
Date of Exp.: 02-06-2023
Driving license no 8323/04-05
Language known English, Hindi,Oriya & Bengali
Educational
H.S.C. (B.SC)
Qualification
TECHNICAL QUALIFICATION
BARC ASNT
LEVEL II(RT) (Radiography Testing)
ASNT ASNT
ASNTLEVEL LEVEL II(UT) (Ultrasonic Testing)
II(RT)
LEVEL II(MT) (Magentic Particle Testing)
Site I/C(Govt.
of India LEVEL II(LPT) (Liquid Particle Testing )
Mumbai)
SUMMERY OF WORK EXPERIENCE
15 years experience in Oil and Gas industries, Fertilizer and cross country pipeline both in India & overseas
in onshore & offshore division during this period my work activity is industrial X-ray RT,UT,MT,PT, all type
of N.D.T work. At Mumbai working in OTIS(I) Pvt. Ltd as a site in charge.
Industrial X-ray or Radiography testing of pressure vessels, piping structures Napatha, Ammonia and
Oil Storage Tanks Boilers Casting and Forgings etc.
Ultrasonic examination of Raw materials, cled and plain plates. Buttwelds, full penetration joints,
various offshore structures and piping jobs and Thickness Survey of pressure vessels, piping,
reactors etc.
BY-EX-10, Ex-100, Epoch-4B, D1SISCAM DS-1,
Interpretation of Radiographs of weldments, castings and forgings against various codes and
standards.
Magnetic particle Testing of piping, pressure vessels AMMONIA, STORAGE TANKS, Offshore
structures and extension deck by using DRY, WET FLO URL SCENT AND NON FLOURESCANT
METHODS WITH YOKE AND PROD TECHNIQUE
Liquid penetrate tastings of weldments of offshore piping pressure vessels, structures by using
solvent removable water washable method with FLOURESCANT and NON- FLOURESCANT
method.
JOB HANDLED IN INDIA WITFI VARIOUS ORGANISATION.
Offshore projects for ONGC, HYUNDAI, SAMSUNG, ESSARL & T,IPCC, BPCL, KAPP, TAPP,
RPL Jamnagar, ENRON, MDL, KAVARNER, MIS AMC, (GGCLGujurat) cross count VSPL
project with Punjliyod ltd. and DVPL project with punjliyod ltd., MKPLwith ABAN and capability of
handling site individually.
JOB WITH OVERSEES ORGANISATION
Through Cooper heat working in Kuwait National Petroleum Company (KNPC) as NDT
TECHNICIAN, with UT,MT, PT. Worked in Qatar offshore under Hyundai heavy industries for
MAERSK oil, (Qatar Oil Field) during this period job activity as an NDT Co-Ordination. With
specially UT job on piping weld joint and structural old joint. And as an NDT Tech in Yemen with HTC
INTERNATIONAL LTD. FOR (CANADIAN NEXEN and TOTAL OIL F1LD IN YEMEN. At that
time my job was by JME Crawler internal X-Ray. But now am doing individually job by own
instrument of RT, UT, MPT & ST also.
TYPES OF JOB EQUIPMENT USED IN INDUSTRIAL X-RAY
Types Of Job Equipment Used
1. Radiography Testing lr 192 Gama Equipments Techopes
(INDUSTRIAL X-RAY) SPEC-2T ROLY, TELETRON,
X-RAY MACHINE -ICM,
TRONEX, ANDREX .
t
2. ULTRASONIC TESTING
5
(On Piping And Structural)
.
EX 10,EX 100, EPOCH 4B
L
DIGISCAN, DS-1,
i
q
u
i
d
3. CRAWLER JOB
P
(I) J.ME.(MADE IN
e
UK
PIPE Ø n
6"to 60" e
(II) IPSI t
(MADE IN r
FRANCE Ø) a
t
e
4 K
A
T
e
s
t
i
n
g
6
.
H
a
r
d
n
e
s
s
T
e
s
t
i
n
g
7
.
F
e
r
r
i
8.PMI
9 Holiday Detection
D
CODES AND STANDARDS
& FAMILIARITY
Experience Codes Such As
API 1104, ASME Sec VIII
ANSI B, AWS Dl.l
WORK EXPERIENCE
DETAILS
Presently working in
Leighton project at Iraq Oil
& Gas field pipeline jobs as
NDT Technician/ Crawler
Operator & Interpretater,
using by IPSI crawler with
GFS World.
Period
January 2009 to Till Date.
Designation
Proprietor (NDT TECH )
Organisation
IQIS under GDCL, BHEL,
NCTPS,
NTPC, JINDAL, BALCO
Site
BHEL,
NCTPS, NTPC, JINDAL Site,
BALCO, VISSA,
GAIL etc.
Inspection
EIL,
TENB etc.
Job profile
Internal X-ray and
External X-ray with
N
All
NEX
type of
N.
Radiograph
y, MPI, UT,
LPT,
And (S/R) Stress Relieving
Jobs.
Period
October 2004 to March
2005.
Designation
NDT TECH (INDUSTRIAL
X-RAY )
HTC Yemen
INTERNATIONAL LTD
(Yemen)
S Inspe
ction
Job
Profi
le
CAN
ADI
AN
NEX
EN
AND
TOT
AL
NEX
N
and
TOT
AL
Inter
nal
X-
ray
and
Exter
nal
X-
ray
N ordina
tor
June (with
2003 UT)
P to PUN J
D
Sept LIYO
S
emb D
I er LTD,
2003 (INDI
NDT A)
P supe Dahej
S
I rviso vijapu
J r r
HY pipeli
UD ne
AI projec
HEA t
VY (Gujur
IND at)
UST EIL
RIE INTE
S, RNA
QAT L X-
AR. RAY
Qata of 150
r Oil km
Field cross
(offs countr
hore) y
BVI pipeli
S ne(D
UT VPL
jobs projec
on t SP II
pipin At
g Gujrat
proc )
ess
platf
orm P nation
and Organi
com sation
press Site
or
Mod Inspec
ule. tion
Job
Octo profile
ber
2003
to
Nov
emb
er
2003
J joint
at
S
V km P Februa
E 10 Ø ry
E O
cross 2002
S
count To
ry March
I
pipel 2002
ine UT
(VSP TECH
L NICIA
N
proje
AND
ct
CRA
SP-
WLE
V at)
R
OPER
ATOR
Punj
liyod
ltd,
(INDI
A)
Ambol
i to
Jhago
dia
cross
countr
y
Pipeli
ne
(GGC
L,
GUJU
RAT)
BAXC
OUNS
EL
UT on
Tiein
joint
and
Intern
al X-
ray by
crawl
ear
(22km
12" Ø)
Organi
P
sation
D
Octo u
ber
S
2001
I To Februa
Janu ry
ary 2001
2002 To
NDT April
TEC 2002
HNI CRAW
CIA ELER,
N OPRE
AL ATOR
-RA (X-
SHE RAY
D TECH)
COO Hyund
PER ai
HE Heavy
AT( Industr
KU ial
WAI Bomba
T) y High
Kuw (ONG
ait C)
Nati WIPR
onal P
Petro submar
lium ine
Com pipelin
pany e
(KN project
PC, on
KU barage
WAI - HD
T) 289
KNP EIL
C Interna
inspe l X-
ction ray
Dept cralar
. unit
UT, and 6"
MT, Ø, 10"
PT Ø, 12"
on Ø,
pipin under
g, water
tanke pipelin
s, e.
and
Thic
knes
s
meas
Period
Period
January 2000 To may 2000
June 2001 To Sept 2002
Designation :
Designation
Site incharge and UT
Crawler Opreator.
technician
Organisation
Organisation :
Chenington Drilling
Kvaerner Energy.
Services.
Site-
Site
Bombay High South Revamp
URAN (MUMBAI)
Project on
Inspection
Navajo barge
(ONGC
EIL. (IOCL)
offshore)
Job profile
Inspection
3km. and 10" Ø,cross
:
country pipeline x-ray
by internal
EIL
crawler
Job profile
unit.
UT, RT, MT on pipeing
Period
structure and inside
of Turbine
October 2000 To November
Generatio
2000
n
Desigination
Period
NDT TECHNICIAN
Organisation
September 1999 To October
1999
OHCS (INDIA) PVT.LTD.
Designation
Site
Bombay high (ONGC Multi NDT Technician.
offshor) WIN Organisation
platform.
Inspection M/s AMC Singapore.
Site-
EIL
Job profile
Bombay high. (ONGC
offshore BHN
Radiography, MT, PT on
platform)
water injection platform, Inspection
sound
Electro- DNV
Chlorinatio
Job profile
n
Refurbisme
RT, MT, PT on 32" Ø NF
nt
RISER Pipeline
Programme.
Replacem
ent on
(Barage
sermax Mumbai,BPCL,Jamnagar
2000) RPL Negothane
IPCL
Period
EIL
BACTA
November 1999 To March
L
1999
RT,
Designation
MT,UT,
PT of
Site-incharge with (specially
piping
UT technician)
and
Organisation
inspecti
on
HYUNDAI HEAVY
refin
INDUSTRY
eries
Site-
Heat
Exchan
Bombay High (ONGC
ger.
offshore BCP-B platform)
Inspection
January
EIL
1998
Job profile
To June
1998
RT,UT,MT PT, of piping
NDT
modification creation
TECH
and high
NICIA
Thick.
N
Radiograph
L&T
y job
Bomba
material
y high
DSS, SDSS
(ONG
and
C
Incloid
Offshor,Cloid with
e
cuni- on
HRA,H
barge
RG,
HHI 2500
HRC
and sarmex-
platfor
2000
m)
EIL
Period
May 1998 To RT
December 1998 interpra
Designation tator
and
MT
NDT TECHNICIAN,PT,job
Organisation
at
piping
Various Refineries
weld
(RPL,IPCL,BPCL)
joint
Site-
on( Bar
ge
GAL
Dece
mber
1997
To
Janua
ry
1998
NDT
TEC
HNIC
IAN
L&T
Bomb
ay
high
(ONG
C
offsh
ore )
EIL
RT
MT
PT
and
RT
interp
rtatio
n for
HX-
HY
modi
ficati
ons
Inspe
ction
of
pipin
g job
on
(Barg
e
GAL
Const
ructor
)
Janua
ry
1997
To
Dece
mbar
Site
Period
OFFSHORE ENRON
OIL FIELD OF
December 1996To Feb.
TAPTI
1997
PLATFORM.
Designation
Inspection
NDT TECHNICIAN
EIL
Organisation
Job profile
OHCS (I) PVT.LTD
Radiography of
Site
piping weld joint.
Bombay High (ONGC
Period
offshore)
Inspection
EIL
Dec. 1995 To April
Job profile
1996
RT,MT,PT on BPA-
Designation
BPB,BA,BB,HG platform
of piping
NDT TECHNICIAN
modification
and irection. Organisation
OHCS (I) PVT.LTD.
Site
Period
Bombay High (ONGC
August 1996 To Nov. 1996
offshore)
Designation Inspection
Radiographer
EIL
Job profile
Organisation
BPCL, Mumbai
Radiography of piping
Site
weld joint
BPCL, Mumbai
Inspection
Period
EIL
Job profile
May 1995 To Nov.
Radiography of
1995
piping weld joint.
Designation
Period
Radiographer
Organisation
May 1996 To July
1996
OHCS (I) PVT.LTD.
Designation
Site
Radiographer
OHCS fabrication
Organisation
yard mumbai and
B
OHCS (I) PVT.LTD om
bay
H 1200 barge of HOOK
i up
g
SBHT to be
h
project of piping
O
and structurally
N
G joint.
C
o I d o hereby solemnly declare
ff
that all the information provide
s
are true and correct to the best
h
of my knowledge and belief.
o
r
e
)
I
n
s
p
e
c
ti
o
n
E
I
L
Job profile
RT,MT PT at
offshore platform on
piping
and structural Joint
Period
Jan. 1 995 To April
1995
Designation
NDT TECHNICIAN
Organisation
Hyundai Heavy
Industries
Site
Bomay High
(ONGC offshore )
on HHI
1200 barge.
Inspection
EIL
Job profile
RT MT PT on HHI