Post Job Free
Sign in

Quality Assurance Technician

Location:
Titusville, FL
Posted:
March 04, 2014

Contact this candidate

Resume:

STEWART L. JONES

**** *** ******** **.

Titusville, Fl. 32780

Home 321-***-****

Cell 321-***-****

E-mail *************@*****.***

OBJECTIVE

Seeking position as a Non- Destructive Testing Technician/ Supervisor/ Quality Specialist

SUMMARY OF QUALIFICATIONS

Twelve years of experience as a Non- Destructive Technician, along with several years of

experience in a supervisory position to include Quality Supervisor. All certifications are

according to NAS 410, SNT-TC-1A, and CP189 and mil standards in Level II PT, MT, UT, and

RT methods, ET can be obtained. Previously held certification in flight safety standards, along

with hardness testing and conductivity testing. Two years of experience as a Maintenance

supervisor. Previously held and can obtain a security clearance. Former Internal ISO 9000,

AS9100 auditor. Can obtain Level III PT, RT, MT certifications.

EMPLOYMENT HISTORY

Inspector UT Immersion testing Level II October, 2013 to Present

Uniteck Radford, Va.

Perform UT inspection using immersion testing systems certified through BAE systems and to

NAS 410, SNTC-1A. Perform inspection on explosive materials to a given standard. Calibrate

equipment to maintain correct amplitude requirements. This is a contract Job.

Quality Specialist/ Lead Level II RT Tech September 2008 to October, 2013

Kaman Precision Products Inc. Orlando, FL

Performed duties as Lead level II RT real time/ Digital inspector/ film interpreter. Responsible

for all accept/ reject criteria for real time X-Ray procedures and training for 3 trainees to Level I

certification. Responsible for the scheduling of work for the calibration, tool and Gage personnel.

Assigned duties to 4 team members, such as training on measuring devices and performing

calibration tasks. Assisted in failure analysis boards to help determine root cause and corrective

actions. Maintained the calibration department to keep within NIST traceable standards. MRB

Chair for incoming parts from the suppliers. Non conformance monitor (made sure NC's were

closed with an acceptable cause corrective action). Internal ISO9000, AS9100, NADCAP, 5S

auditor. Assisted in Failure investigations. Performed periodic production floor surveillance

audits. Maintained a good working relationship with DCMA and customers, along with

suppliers. Worked hand to hand with customers and potential customers to meet Quality

requirements.

NDT Tech March 2007 to September 2008

WYLE Labs Kennedy Space Center, FL (NASA)

With 3000+ hours in most methods, I performed Ultrasonic, Level II in UTT, Radiography,

Penetrant, Magnetic particle, and Eddy Current inspections for different programs and different

type of metals at different stages of assembly. Determined thickness and conductivity along with

the different types of indication on the Space Shuttle and all ground support equipment and

lifting devices. Work was done in a lab setting, and also on–site, along with some travel to other

sites. Knowledgeable use of GAMMA and X-RAY devices for inspection.

EMPLOYMENT HISTORY CONTINUED

NDT Tech April 2006 to February 2007

LSI Elizabeth City, NC

With 3000+ hours in most methods, I performed Level II Ultrasonic, Radiography, Penetrant,

Magnetic particle, and Eddy Current inspections for different programs and different types of

aircraft such as Dassault Falcon jet and C-130 planes and several models of helicopters, along

with inspections on manufactured and machined parts. Determined thickness and conductivity,

along with the different types of indication on Helicopters and Fixed Wing Aircraft. Work was

done in a lab setting, also on-site along with some travel to other sites.

Engineer Tech III August 2004 to March 2006

General Dynamics Marion, VA

Performed Level II Ultrasonic Testing and Radiographic imaging of composite materials for

different programs at different stages of assembly. Determined thickness and conductivity along

with the different types of indications such as delams, unbonds, porosity and foreign material

that can happen while parts are in assembly. Worked with Quality Assurance, ISO 9001 and

1004.

NDT Technician January 2003 to August 2004

Sikorsky Aircraft Stratford, CT

Performed Magnetic Particle and Liquid Penetrant inspection on production, used or overhauled

parts. Performed Rockwell hardness on steel and aluminum, as well as conductivity. Held Level

II certification in MT, PT and flight safety part Inspector to include critical characteristic parts. I

also performed and documented new techniques for new parts. Worked with Quality Control and

Product Integrity under NADCAP, ISO 9001 and 1004.

Supervisor/ NDT Tech January 1995 to January 2003

U.S. Army

Maintained and operated all NDT Equipment while being responsible for the professional and

personal needs of personnel in my section. Monitored and scheduled all maintenance and

inspections done in my shop or on-site. Maintained a commendable performance level on all

safety practices, along with developing a radiation safety program for the RT inspections done in

the hangar. Monitored and passed out work schedules for NDT inspections and maintenance

work. Performed track and balance with AVA equipment on Uh-60, CH 47 and UH-1 rotary wing

aircraft (68D20N2 MOS).

EDUCATION

Certificate in Non Destructive testing- Pensacola Naval Air Station, FL, 2001

Certificate in Aviation Safety- Sinai, Egypt, 2001

General studies- University Of Maryland, Sinai Egypt, 2002.

General studies- Sacred Heart University, West Haven, CT, 2004

Level II Eddy Current- Hellier NDT School, Oct, 2006

Radiation Safety course- Wyle Labs (NASA), 2007

Digital Radiographic 40 Training- NSI, 2013

References, prior clearances held and salaries available upon request.