Substation Electrician

Experienced construction and power maintenance station electrician.

Maintaining Substation Equipment, construct & assemble towers, switches,

transformers, cvt's, reactors, structures.

AREAS OF EXPERTISE

Substation Maintenance Circuit Interrupters

Familiar with Safety Codes Oil Sampling &Testing

Transformers Servicing and Inspecting Equipment

Updating substation logs and equipment Troubleshooting

records

Reading Schematic Diagrams Planning, Coordinating and Supervising

Projects

Protections Testing Breakers

Air Break Switches Rectifiers and Batteries, 48 - 129 VDC.

Confined Space Training (Supervisor &

Rescue) SF6 Gas Handling Training

Work Protection Emergency On-call Qualified

High Votlage Sub Station Switching Bucket Escape & Tower Rescue Qualified

Qualified Crew Supervisor (Foreman)

Supervisor Training Levels 1 & 2

Qualified to Run/Direct Crew, Time

Sheets, Order Materials, Order

Equipment (Man Lifts, Trucks, Oil

Press, Degassifiers, Vacuum Systems,

Cranes

EDUCATION & WORK HISTORY

HYDRO ONE, Hamilton 2007 - Present

Ontario, Canada

Sub Station Maintenance Electrician

Employment Experience:

Transformers 13.8 - 230 KV

. Oil Processing and Testing

. Tap Changers Inspection / Re Build

. Cooling Systems

. Bushing Replacement

. Oil Sampling

. Repair / Replace Buss work and LA's

Protections Testing

. Gas Relays

. Cooling Systems

. Fire Systems (HADS)

. Annunciation - Alarms, Taps, Temps

. Doble Testing, Sweep Frequency Test

Breakers

. Oil / Gas - FGK, GMA, KSO, SP, PM72 (SF6)

. Metal Clad - Vacuum, SF6, Solenoid, Spring Actuated

. TTR Testing

. Micro OHM

. Megger Testing,

. Pressure Switches and Alarms

. Rebuild Interrupters

. Recandle, Process Oil,

. Change Bushings

Air Break Switches

. Regular Maintenance & Setup

. Change Insulators and Inspect Drive Mechanism

Circuit Interruptions

. Time and Micro OHM, Verify Target Positions

Other Related Experience

. Aerial Work - 30' - 120' Towers, Buckets, Crane

. Voltages 13.8 - 230 KV

. 4 years HYRDO ONE Emergency response on call

. 4 years (UWPC) Work Protection Qualified

Ontario Power Generation (OPG) 2003 - 2007

Power Generation Station Electrician

Employment Experience:

. Nuclear and Hydro Generation Station Maintenance

Industrial Electrician

1991 - 2003

* Bethleham Steel - Buffalo, New York

. Working for contractors in substations,

. Transformers

. Generators

. SCR Banks

. Lines, Tower Steel Construction and Errection

. Electrical License Upgrade to 309A Construction Maintenance

Residential & Commercial Electrical apprenticeship 1985 - 1991

Community College

. Centennial College

. George Brown College

. Electrical License 309C Domestic / Rural

ADDITIONAL INFORMATION to note:

. US Citizen

. No Criminal History

. Florida Driver Licence

. Clean Drivers License History - Class "D" = 11,000KG

. Bilingual - Fluent French & English

. Native American Indian Status

. Relocating to Florida

. All Training records and certificates available upon request

. Kitesurf, mountain bike, road cycling, SUP



Contact this candidate