Post Job Free

Resume

Sign in

Electrical Control

Location:
Karachi, Sindh, Pakistan
Salary:
5000US dollars
Posted:
November 03, 2013

Contact this candidate

Resume:

AHMED MUNIR

A*-***, Madina Blessing, Block **-A, Gulshan -e-Iqbal, Karachi.

Cell# +92-345-*******

Email: acaoby@r.postjobfree.com

OBJECTIVE:

Interested in being part of a progressive and reputed organization so that

my theoretical knowledge along managerial skills can be further supported

and strengthen.

EDUCATION:

* MS in Electrical Control from National university of Science &

Technology, Pakistan Navy Engineering College Karachi in September 2013

with CPGA 3.0

* Bachelor of Engineering in Electronics from NED University of

Engineering and Technology in December, 2009 with 3.4 CPGA or 73%

* Secured A-1 Grade/(907/1100 or 82.45%) in HSC examination headed by

Board of Intermediate Education Karachi in Pre-Engineering from GOVT

DEHLI COLLEGE, 2005

* Secured A-1 Grade/(717/850 or 84.35%) in SSC examination headed by Board

of Secondary Education Karachi in SCIENCE from PLACID HIGH SCHOOL, 2003

WORK EXPERIENCE:

Assistant Manager at SGTPS-II KESC (E & I/C): OHSAS

18001-2007 Certified (More than 3 years' experience

Dated: 9th of August 2010 till present

The SGTPS-II power plant is capable of producing 90MW with the help of 32

GE-Jenbacher 620 Gas Engines; each engine is capable of producing 3 MW each

but is set to produce 2.379 MW due to ambient conditions.

There are also five 25MW Gas Turbines of Hitachi. These turbines are of 5

Frame, one of them is used for Black Start Condition and others are not in

running conditions due to poor efficiencies and low gas pressure.

Responsibilities:

Administrative:

* Deeply involved in training of lower staffs by giving presentations with

basic knowledge and animation to enhance their understanding/knowledge

related to plant and equipment installed on engines

* Prepare SOP about reviewing previous faults which have been occurred for

electrical team in order to perform job safe and sound and according to

HSEQ standards.

* Do Tagging on electrical Equipment's in Control Panels of the control

room. This activity helps me to learn about the position of breakers and

contactors of motors, compressors, bus-ties etc.

* Prepare weekly activity report and assigned daily based activities to

workers

* Prepare key performance identification report for the department on

monthly basis which shows MAN Hour Utilization in Department and Response

time to corrective notifications.

* Maintain record of the spares used during troubleshooting and keep

history of previous alarms in order to reduce mean time of repair.

Technical/Maintenance:

Electrical Side:

* Prepare Maintenance schedule and take part in maintenance of GE Jenbacher

engines. The maintenance is scheduled according to the running hours of

the engines.

* Troubleshoot any electrical fault related to DC supply restoration,

solenoid operation for Ratcheting, and remote and local panel operation

of Hitachi frame 5 Gas Turbines. technical manuals and engineering

drawings.

* Note down the electrical faults from the daily activity log book and make

a record of fault frequency and spares replacement in order to prepare

list of electrical equipment's for budget

* Deeply involved in troubleshooting of AREVA 11KV (VCB), Low voltage 400 V

AREVA PANELS and ABB GIS / 132KV (SF6) breakers panels side which is more

than 30 years old.

* Generate Notification for Maintenance, prepare work permit and work order

for maintenance work on SAP module Plant Management.

* Take Vibration Measurement on ISO 2372 (10816) Standards with LEONOVA

Infinity instrument to evaluate vibration severity in GE JENBACHER 620

GAS engine which operates on 1500 rpm. This standard is for machines

operating in the 10 to 200 Hz (600 to 12,000 RPM) frequency range.

* Do Megger of Siemens, Hitachi 30MVA/2MAV/1800KVA transformer, and prepare

its record in regular basis.

* Perform Di-electric test of oil filled cable (alarming limit is less than

45 KV according to IEC 60156 Test Standard IEC 60422) and transformer

oil, keep its record. Recently this timely test help us to perform

Centrifuging on one of 30MVA Transformer (alarming limit is 40KV but test

result was 29 KV) after two days centrifuging this result increases to 63

KV.

* Siemens, ABB & Grundphos motors upto 14KW motors Maintenance

Instrument Control Side:

* ABB Total Flow Gas Chromatograph periodic maintenance and

troubleshooting.

* Monthly inspection and calibration of natural Gas Chromatograph of ABB,

TOTAL Flow NGC 8206 through PCC32 software.

* Troubleshooting of B & R PLC through Automation Studio 5.0 software and

logic verification.

* Siemens Simatic S7 200 CPU 222 PLC logic verification installed on Screw

Type Air Wuxi Air Compressor.

* GM BH Pressure Transmitter and Temperature transmitter yearly

calibration.

* Jenbacher 620 Dia NE XT, DCS controls through SERVER based System

* Actrix Gas flow meter Maintenance of Fluxi 2200 /TZ Dn 200

* Acvatic TCV calibration

* Temperature Gauges (Fantinelli) & Burdon Tube Pressure Gauges (Wiki)

yearly calibration. XPi3 calibrator

PROJECTS:

Restoration of DC/AC Control Supply for 32 years old BBC GIS System:

The 132KV GIS SF6 System of Site Gas Turbine Power Station is more than 32

older old and Site II feeder in this system is the backbone or central node

for all other 132KV SF6 bays in respect to control supply. The distribution

of control supply to other bays is first to terminate to it and then go to

DC & AC Supply Panels. After fire incident the Supply near its dead feeders

cause damaged to this feeder too. Its restoration was critical in order to

restore the complete Plant to normal. Major activities were performed

during its restoration as follows:

* As system was 32 years old so electrical drawings were not properly

maintained. First complete drawing regarding control supply and

protection were arranged from plant old scrap yard and other old grid

station in no time

* Complete Study of drawings regarding control supply, protection scheme.

* Damaged feeder isolated from healthy feeder in respect to control supply.

* Complete troubleshooting performed in isolating and restoration of DC

Supply

* Compare and point out all cables termination.

* Arrangement of man resources and new cables for replacement with the

damaged control cables from local power stations.

Testing of Protection Cables with SVERKER 750/780:

* After cables terminations, testing of protection schemes and cables with

SVERKER 750/780 millivolts and milliamps injector to verify that all

protection and tripping schemes are remains in contact and working.

Modification in Old Existing Fire Alarm with Local Spares:

The old fire alarm system of SGTPS plant comprises of 4 check points with

control panels and hotter at different places. There is leakage of voltages

in triggering cables which are laid complete in cemented trenches; this

leakage of voltages became severe during raining period or sewage leakage,

resulting in false triggering of fire alarm. The obvious solution with the

mentioned senior was to replace the cables, but this requires huge length

of cables approximately 1.5 km and large amount of man power to remove

cemented cables trenches.

Old Strategy:

Old control strategy was based on single push button and separate timer in

each panel, so when there is leakage in cable the fire alarm get trigger or

when fire alarm get tested the timer contact remain latched when the

operating time get over.

Modified One:

To reduce cost and man power, a new control strategy was designed, which

comprises of 4 control relays and one contactor and two timers with old

laid cables. All four relays installed in each 4 control panels with one

contactor in main control panel to handle one hooter and six lights. The

push button operate relays which trigger timer which in turn operate

contactor and put hooter and light on.

Counting and Sorting of IRON SHEETS using Atmel 89c52 for Pakistan Steel

Mill:

The project was to identify the faulty steel sheets among the correct

sheets, count them and track them to the three sections (one for faulty and

two for correct sheets) in order to sort out. The decision whether the

sheet was faulty or not, made on thickness and physical quality of sheets.

The whole control logic was built on assembly language and Atmel 89S51 was

used to meet controlling objectives. The counting result was continuously

displayed on 12 Seven Segments (4 for one section).

Intranet -SCADA using LABVIEW and Atmel 89S51 Microcontroller:

The project was about to measure the water level of Dam and Reservoir,

transmitting the measure data to LabVIEW by interfacing 89S51 serially with

LabVIEW and control the valve. Data obtained in LabVIEW was logged in the

local database and also sent to LAN's TCP server and an http server for

viewing as a webpage.

PUBLICATION:

* Ahmed Munir, Zahid Ali Siddiqui, M. Faizan Sherazi, S. M. Danish, Design

of Low Cost Embedded System for Automation of a Parallel Processing

Plant, Proceedings of the 2011 International Conference on Advanced

Mechatronic Systems, Zhengzhou, China, August 11-13, 2011

* A. Munir M.N. Ashraf, S.A.B. Khalid and M.S. Ahmed, Implementation of

Intranet-SCADA using LabVIEW based Data Acquisition and Management,

Proceedings of the International Conference of Computing in Engineering,

Science and Information, Fullerton, CA, USA, April 2009

WORKSHOPS:

* 3 days workshop on "Digital Chip Design using Verilog Hardware

Description Language (HDL)" by Mr. Mustafa Imran Ali(Senior Design

Engineer, Digitek Engineering) during 23-25 December 2007

* 4 days workshop on Machine Vision by Mr. Muhammad Zeeshan Zia (have

completed masters in Image Processing from Technical University of

Munich Germany) in December 2008

SKILLS AND ABILITIES:

TECHNICAL SKILLS:

Microcontroller: Atmel 89S51, 89C51, 89S51, 89C52

Programmable Logic Controller (PLC): Siemens Simatic PLC

Programming languages: Matlab, C, Ladder, Assembly, Verilog

(HDL)

Simulation software: ModelSim (Verilog /HDL), Proteus v6 and v7 (Atmel

8951, 8952)

FPGA Tool: Altera Quartus II

National Instruments Software: Multisim v10.0, LabVIEW v8.5

IC Design Software: Cadence

HONORS AND ACHIEVEMENTS:

* In charge of Speed Programming Competition in Student's Project

Exhibition and Competition (SPEC) held on 12thApril 2008, organized

under the supervision of Electronics Department of NEDUET.

* Participated in Science Fair conducted by Society for the promotion of

Science, Engineering & Technology (SENTEC) in June 2007

* Awarded a Certificate of Merit in Academics in 2006 for securing A-1

Grade in HSC examination headed by Board of Intermediate Education

Karachi by Government Delhi College

PERSONAL INFORMATION:

FATHER NAME: MUNEER AHMED DATE OF BIRTH: 05-06-

1988

NATIONALITY: PAKISTANI RELIGION: ISLAM

MARITAL STATUS: Married NIC: 421**-*******-

1

DOMICILE: KARACHI PTCL NO: 021-********

REFERENCE: Will be furnished on request.



Contact this candidate