PROCESS CHEMIST
G.GNANA KANNI RAJA
Thanavala nallur,
Viragalur (PO) Lalkudi (TK)
Trichy (DT), TamilNadu (state) Passport Number: T2739991
India. PIN NO: 621772 Mobile No: +968-******** E-mail: *************@*****.*** Mobile No: +919*********
PROCESS CHEMIST AT POWER AND WATER DESALINATION PLANT
YEAR OF EXPERINCE: 12 years
DESIGNATION : Process Chemist Power & Water Treatment Plant (O&M)
Gulf Experience
Name Of Company
Location
Power plant Capacity
Desalination Water Plant Capacity
Duration
Global Chemicals and Maintenance System L.L.C
RAECO-Al Duqm
150MW
8000 M3/Day
01.02.2019 to Present
Sogex Oman LLC
Barka ıı Power And Desalination Plant ENGIE Sueız-Tractable O&M Oman
Companied Cycling Boiler(GT+HRSG+ST) 678 MW
120000 M3/Day
19 November 2014 To 08 December 2016
Honfincons
Quesscorp Limited
Chettinad Cement Ariyalur
15*3 =45 MW
42 M3/Hrs.
10may 2017 Working Still
Desin O&M Plt
Dalmia Power Plant
27 + 18 = 45mw
30 M3/Hrs.
7april2010to7october 2014
Oeg India Plt
Sabari Industries (P) Ltd
6 Mw
5 M3/Hrs.
June15th 2009 To7april2010
Enmas Operation& Maintains Service
RR.Energy,Raigerh, Chhattisgarh
15 MW
50m3/Hrs.
August 21st 2008 To June2009
Enmas Operation& Maintains Service
Arrbindo Aggro Power Limited
8 MW
8 M3/Hrs.
May 2007 To August 2008
Previous Experience
ACADEMIC RECORDS
Course
Institution
Board/ university
Year of passing
% of marks
PG DIPLOMA IN QUALITY MANAGMENT
School of Quality Management
Bharathidasan University
2007-2008
75
B.Sc., (Chemistry)
E.V.R College, Trichy
Bharathidasan University
2004-2007
59.9
Higher Secondary
ST.PetersHigher Sec School Trichy
State board
2002-2003
57
OPERATION.
DCS, SCADA operation & Manual plant operation of water treatment plant –DMF, MF, UF, RO desalination plant, DM plant, Re-mineralization, cooling tower, STP, ETB.
Companied cycling Boiler (HRSG), AFBC Boiler water dosing, Boiler water treatment, Lab test analysis, chemical preparation, Quality (QC/QA) maintains.
Save water, chemical cost, Energy saving.
Safety environment
TEST& ANALYSIS
Pre-treatment plant Test – PH, conductivity, chlorine, Particle condor analyzer, Turbidity (NTU), SDI, Jar test, algee meter.
RO- plant- Analysis of Feed water, permit, ORP, PH, TDS, Boron, and Reject water out fall analysis AAS (Atomic absorption spectroscopy).
Re-mineralization – PH, conductivity, Free chlorine(ppm),Fluoride(ppm), NTU,LSI,
Total hardness (ppm), chloride (ppm), CO2
Demineralization—(SAC, SBA, MB) PH, SC, Silica, ferric ion (ppm) spectrophotometer.
Boiler water analysis - . PH, SC, cation conductivity, Dissolved oxygen, N2H4, NH3, Sio2, Fe3, phosphate, copper, spectrophotometer & Online swan meter calibration.
Oil, coal, Lignite, bed material analysis Test of (GC, Viscosity, Bomb calorimeter, GCV, TM%, Ash%, FC %, Bulk density) Lab equipment usage.
Received chemical quality analysis and daily chemical consumption report record submit. Monthly, daily, shift analysis report prepared to submit department & management.
BOILER WATER TREATMENT LAB ANALYSIS OF OPERATION PARAMETER MAINTAINS.
Tract removable corrosion and scale formation. Specification of all Parameter according within quality maintains to dosing system reporting update record submit.
Determine online meter (pH, SC, CC), swan meter, Sodium analyzer, flower meter, calibration maintains to ppm. Cat-ion conductivity column regeneration and maintains µS/cm calculation.
LP Dosing (Hydrazine) (Ammonia), LP-HP Drum Dosing chemical (Tri-sodium phosphate) prepared dosing stock adjusted. LP, HP Drum CBD, IBDgiven.
MCW, CCW- cooling tower water parameter analysis added to inhibitor chemical maintains.
Determine feed water analysis, Drum (CBD flow), saturate steam, Main stream, Condensate water test in lab. All parameter with in specification limit maintains.
GT/HRSGmaintains the CEMS- system of parameter (NOx, Sox, CO, O2).Noise monitoring.
DESALINATION PLANT OPWRATION OF LAB ANALYSIS PARAMETER MAINTAINS;
Raw water removed (NOM) natural organic material Shock dosing (chlorination), Fecl3 H2SO4,Dual media filter (DMF), MMF, Ultrafiltration (UF), Microfiltration (MF) operation to SMBS (Dechlorination), ORB, dual media filter rate, Turbidity, SDI maintain.
Determine sea water and out fall sample AAS method report submit.
RO-First pass, second pass feed water, permit, reject,% of Recovery flow, salt pass, rejection, calculation, differential pressure, Fouling monitoring .
RO- membranes, UF, MF alkaline &acid effective chemical (CIP- STPP, EDTA, citric, DPNPA) cleaning, Micron filter replace and serves.
Portable water adds chemical are preparation Nalco, NaF, CO2, Lime dosing (ppm) parameter test analysis of stander method in lab.
Co2plant monoethanolamin (MEA), potassium permanganate, % of CO2Purity maintain.
DEMINERALIZATION PLANT OPERATION QUALITY MAINTAINS:
DM plant SAC, SBA, Mixer bed, regeneration, quality of pH, sc,sio2online and labanalysis parameter test.Neutralization pit maintain pH add acid and caustic soda.
DCS control room operation properly. DCS system make ABB.
Plant operation and regeneration, SAC, SBA and MB, Resin replays & top up.
Sewage Treatment Plant, Wastewater Treatment all pH according to specification maintains.
HCL, lye, Alum, polymer, Coagulant, Flocculent – stock maintains to requirement.
COOLING TOWER;
Water analysis & maintains, COC- Concentrate of cycling, FRC, LSI maintains, Makeup water, bled water, evaporation loss maintains. Incubator of corrosion, Scale formation remove chemical prepared.
EXTRA CURRICULAR ACTIVITES
MS-Office Type write
Microsoft Excel
Microsoft Outlook
PERSONAL PROFILE:
Father’s Name : S. GNANADURI
Date of Birth : 15.02.1985
Sex : Male
Nationality : Indian
Mother Tongue : Tamil
Languages Known : Tamil, English & Hindi
DECLARTION
I here declare that the above information is true and correct to the best of my knowledge and belie.
Place:
Date: (G.GNANAKANN RAJA)