Post Job Free
Sign in

Power Plant Water Treatment

Location:
Tamil Nadu, India
Posted:
September 03, 2019

Contact this candidate

Resume:

PROCESS CHEMIST

G.GNANA KANNI RAJA

Thanavala nallur,

Viragalur (PO) Lalkudi (TK)

Trichy (DT), TamilNadu (state) Passport Number: T2739991

India. PIN NO: 621772 Mobile No: +968-******** E-mail: *************@*****.*** Mobile No: +919*********

PROCESS CHEMIST AT POWER AND WATER DESALINATION PLANT

YEAR OF EXPERINCE: 12 years

DESIGNATION : Process Chemist Power & Water Treatment Plant (O&M)

Gulf Experience

Name Of Company

Location

Power plant Capacity

Desalination Water Plant Capacity

Duration

Global Chemicals and Maintenance System L.L.C

RAECO-Al Duqm

150MW

8000 M3/Day

01.02.2019 to Present

Sogex Oman LLC

Barka ıı Power And Desalination Plant ENGIE Sueız-Tractable O&M Oman

Companied Cycling Boiler(GT+HRSG+ST) 678 MW

120000 M3/Day

19 November 2014 To 08 December 2016

Honfincons

Quesscorp Limited

Chettinad Cement Ariyalur

15*3 =45 MW

42 M3/Hrs.

10may 2017 Working Still

Desin O&M Plt

Dalmia Power Plant

27 + 18 = 45mw

30 M3/Hrs.

7april2010to7october 2014

Oeg India Plt

Sabari Industries (P) Ltd

6 Mw

5 M3/Hrs.

June15th 2009 To7april2010

Enmas Operation& Maintains Service

RR.Energy,Raigerh, Chhattisgarh

15 MW

50m3/Hrs.

August 21st 2008 To June2009

Enmas Operation& Maintains Service

Arrbindo Aggro Power Limited

8 MW

8 M3/Hrs.

May 2007 To August 2008

Previous Experience

ACADEMIC RECORDS

Course

Institution

Board/ university

Year of passing

% of marks

PG DIPLOMA IN QUALITY MANAGMENT

School of Quality Management

Bharathidasan University

2007-2008

75

B.Sc., (Chemistry)

E.V.R College, Trichy

Bharathidasan University

2004-2007

59.9

Higher Secondary

ST.PetersHigher Sec School Trichy

State board

2002-2003

57

OPERATION.

DCS, SCADA operation & Manual plant operation of water treatment plant –DMF, MF, UF, RO desalination plant, DM plant, Re-mineralization, cooling tower, STP, ETB.

Companied cycling Boiler (HRSG), AFBC Boiler water dosing, Boiler water treatment, Lab test analysis, chemical preparation, Quality (QC/QA) maintains.

Save water, chemical cost, Energy saving.

Safety environment

TEST& ANALYSIS

Pre-treatment plant Test – PH, conductivity, chlorine, Particle condor analyzer, Turbidity (NTU), SDI, Jar test, algee meter.

RO- plant- Analysis of Feed water, permit, ORP, PH, TDS, Boron, and Reject water out fall analysis AAS (Atomic absorption spectroscopy).

Re-mineralization – PH, conductivity, Free chlorine(ppm),Fluoride(ppm), NTU,LSI,

Total hardness (ppm), chloride (ppm), CO2

Demineralization—(SAC, SBA, MB) PH, SC, Silica, ferric ion (ppm) spectrophotometer.

Boiler water analysis - . PH, SC, cation conductivity, Dissolved oxygen, N2H4, NH3, Sio2, Fe3, phosphate, copper, spectrophotometer & Online swan meter calibration.

Oil, coal, Lignite, bed material analysis Test of (GC, Viscosity, Bomb calorimeter, GCV, TM%, Ash%, FC %, Bulk density) Lab equipment usage.

Received chemical quality analysis and daily chemical consumption report record submit. Monthly, daily, shift analysis report prepared to submit department & management.

BOILER WATER TREATMENT LAB ANALYSIS OF OPERATION PARAMETER MAINTAINS.

Tract removable corrosion and scale formation. Specification of all Parameter according within quality maintains to dosing system reporting update record submit.

Determine online meter (pH, SC, CC), swan meter, Sodium analyzer, flower meter, calibration maintains to ppm. Cat-ion conductivity column regeneration and maintains µS/cm calculation.

LP Dosing (Hydrazine) (Ammonia), LP-HP Drum Dosing chemical (Tri-sodium phosphate) prepared dosing stock adjusted. LP, HP Drum CBD, IBDgiven.

MCW, CCW- cooling tower water parameter analysis added to inhibitor chemical maintains.

Determine feed water analysis, Drum (CBD flow), saturate steam, Main stream, Condensate water test in lab. All parameter with in specification limit maintains.

GT/HRSGmaintains the CEMS- system of parameter (NOx, Sox, CO, O2).Noise monitoring.

DESALINATION PLANT OPWRATION OF LAB ANALYSIS PARAMETER MAINTAINS;

Raw water removed (NOM) natural organic material Shock dosing (chlorination), Fecl3 H2SO4,Dual media filter (DMF), MMF, Ultrafiltration (UF), Microfiltration (MF) operation to SMBS (Dechlorination), ORB, dual media filter rate, Turbidity, SDI maintain.

Determine sea water and out fall sample AAS method report submit.

RO-First pass, second pass feed water, permit, reject,% of Recovery flow, salt pass, rejection, calculation, differential pressure, Fouling monitoring .

RO- membranes, UF, MF alkaline &acid effective chemical (CIP- STPP, EDTA, citric, DPNPA) cleaning, Micron filter replace and serves.

Portable water adds chemical are preparation Nalco, NaF, CO2, Lime dosing (ppm) parameter test analysis of stander method in lab.

Co2plant monoethanolamin (MEA), potassium permanganate, % of CO2Purity maintain.

DEMINERALIZATION PLANT OPERATION QUALITY MAINTAINS:

DM plant SAC, SBA, Mixer bed, regeneration, quality of pH, sc,sio2online and labanalysis parameter test.Neutralization pit maintain pH add acid and caustic soda.

DCS control room operation properly. DCS system make ABB.

Plant operation and regeneration, SAC, SBA and MB, Resin replays & top up.

Sewage Treatment Plant, Wastewater Treatment all pH according to specification maintains.

HCL, lye, Alum, polymer, Coagulant, Flocculent – stock maintains to requirement.

COOLING TOWER;

Water analysis & maintains, COC- Concentrate of cycling, FRC, LSI maintains, Makeup water, bled water, evaporation loss maintains. Incubator of corrosion, Scale formation remove chemical prepared.

EXTRA CURRICULAR ACTIVITES

MS-Office Type write

Microsoft Excel

Microsoft Outlook

PERSONAL PROFILE:

Father’s Name : S. GNANADURI

Date of Birth : 15.02.1985

Sex : Male

Nationality : Indian

Mother Tongue : Tamil

Languages Known : Tamil, English & Hindi

DECLARTION

I here declare that the above information is true and correct to the best of my knowledge and belie.

Place:

Date: (G.GNANAKANN RAJA)



Contact this candidate