Post Job Free
Sign in

Medical Quality

Location:
Mohali, Punjab, India
Salary:
7000 $
Posted:
August 09, 2019

Contact this candidate

Resume:

Curriculumvitae

C.SARAVANAN. M.Sc.,

S/o V.Chinnadaikkan Villampatti,(pallivassel), Sathampadi(po),

Natham(tk), Dindugul(dt).Tamil Nadu, India.

Email: ac9086@r.postjobfree.com

ac9086@r.postjobfree.com

Objective:

Intend to build a career with leading corporate of hi-tech environment with Committed & dedicated people, which will help me to explore myself fully and realize my potential. Willing to work as a medical physicist in challenging

& creative environment.

To earn a full-time position as a Medical Physicist.

To work in a highly dynamic work environment, and be a contributing team member.

To experience hands-on experience and work right beside seasoned professionals.

To become integrated team member who is involved with an expanding range of Professional Assignments.

EDUCATION DETAILS:

April 2011

M.Sc (Medical physics) Bharathiar University, Coimbatore, Tamil Nadu,India June 2008

B.Sc (Physics) The American College, Madurai Tamil Nadu,India Working history:

Oct 2014-till date

MEDICAL PHYSICIST

Dept of Radiotherapy, dharamashila, Hospital & Research Centre, New Delhi – 110 092. Radiotherapy SET UP DETAILS: Elekta Units: synergy Linear Accelerator, for VMAT, IGRT,IMRT,SRS,SRT

Varian Clinac S- series Linear Accelerator, for 3DCRT,IMRT

Microselectron HDR V3 Brachytherapy

TPS: TREATMENT PLANNING SYSTEMS:

MONACO Treatment Planning System For IMRT,IGRT, V-MAT, SBRT, SRS, SRT

Eclipse Treatment Planning System for 3DCRT, IMRT

CMS XIO Treatment Planning System for 3DCRT, IMRT

Oncentra Master plan treatment planning system for BRACHYTHERAPY procedures like, tongue implants, Interstitial, Intracavitory DOSIMETRY DETAILS:

IBA 3D Radiation Field Analyzer

Arc Check For Patient Specific QA

IBA Dosimetry Equipments( Chambers and Electrometer) PROFESSIONAL CLINICAL EXPERIENCE:

Annual, monthly, and daily QA and calibration of linear accelerators as per TG-142

Dosimetry and Quality Assurance of Multi energy Elekta synergy and Varian Linear Accelerators.

Source strength calibration and Quality assurance of microSelectron HDR Remote Afterloading Brachytherapy unit

SRS, SRT Planning using Monaco and the associated QA.

IMRT, IGRT, VMAT, treatment planning using MONACO Treatment Planning system

TBI- (Total Body irradiation) Planning, QA and execution

Brachytherapy Treatment planning with Oncentra Master for BRACHYTHERAPY procedures like, Interstitial, Intracavitory

commissioning of new treatment planning software and version upgrades

(Eclipse version 13.6) and Monaco version 5.0.11)

Beam data Measurement of Various Linacs and treatment planning systems

Beam data Verification for treatment planning systems

Quality Assurance for treatment planning systems

patient specific QA for IMRT, IGRT, VMAT by using Arc Check

Quality assurance for MLC,DMLC

Quality assurance for CBCT and aSi based Portal Imaging

Patient management through Aria and Impac/Mosaiq record and verify systems

Simulation procedure with Various CT machines

Feb 2012–Oct 2014.

MEDICAL PHYSICIST

Dept of Radiotherapy, SHANMUGA HOSPITALS, Salem, Tamilnadu-india

.

Radiotherapy SET UP DETAILS: Elekta Units: synergy Linear Accelerator Triple photon & multiple electron energy

THERATRON 780-C cobalt unit.

Microselectron HDR V3 Brachytherapy

TPS: TREATMENT PLANNING SYSTEM S:

PRESICSE Treatment Planning System for 3DCRT

Oncentra Master plan for BRACHYTHERAPY

DOSIMETRY DETAILS:

Multidata 3D Radiation Field Analyzer

PTW Dosimetry Equipments( Chambers and Electrometer) PROFESSIONAL CLINICAL EXPERIENCE:

Annual, monthly, and daily QA and calibration of linear accelerator as per TG-142 Protocol

Dosimetry and Quality Assurance of Multi energy Elekta synergy Linear Accelerators.

Source strength calibration and Quality assurance of microSelectron HDR Remote Afterloading Brachytherapy unit

3DCRT, treatment planning using PRESICSE Treatment Planning system

Brachytherapy Treatment planning with Oncentra Master plan

Beam data Measurement of Elekta synergy and treatment planning systems

Quality Assurance for treatment planning systems

Quality assurance for MLC,

Patient management through Impac/Mosaiq record and verify systems

Simulation procedure with Various CT machines

June2011- Jan2012

MEDICAL PHYSICIST

Dept of Radiotherapy, MS RAMAIAH MEDICAL COLLEGE HOSPITALS, BANGLORE, KARNATAKA

SET UP DETAILS:

THERATRON 780-E cobalt unit.

LDR BRACHY THERAPY

TPS: TREATMENT PLANNING SYSTEM S:

ASHA Treatment Planning System

Post graduation Clinical radiotherapy Practice:

Undergone Clinical radiotherapy practice at department of radiation therapy GKNM Hospital, Coimbatore, during the course of period two years, setup equipped with Elekta Linac-3DCRT,IMRT. And Brachy Therapy, Telecobalt 60 Post Graduation Training:

Undergone one month “Training in Clinical and Radiation Therapy” in Mazhumdhar Cancer Institute, Narayana Hrudhalaya,Bangalore. Training Programme, Conferences & CME attended

23rd AROI state conference TN&PY chapter on 4thand 5th Oct 2008 at GKNM HOSPITAL,Coimbatore-01.

XV Annual Conference of AMPI TN&PY chapter on sept.19-20,2009 at Billroth, Hospital, Chennai (November2009)

Undergone three months Clinical Medical Physics Training at Department Of Radiation Therapy, GOVT RAJAJI HOSPITAL, at Madurai, during thetime of my project work.

Workshop on Radiological Safety for Medical Physicists on 9th and 10th April, 2010 conducted by Bharathidasan University,Tiruchirapalli-24. Personal profile:

Full Name : C.SARAVANAN

Father’s Name : V.CHINNADAIKKAN

Sex, Age and Date of Birth : Male, 26 and 14/05/1987 Nationality : Indian

Religion : Hindu

Residential address : C.SARAVANAN,

S/O V.Chinnadaikkan,Vilampatti

(pallivasel), Sathampadi (PO),

Natham (TK), Dindugul(dt).

Tamil Nadu,India

Email:ac9086@r.postjobfree.com

Mobile: +91-813*******

DECLARATION:

I hereby declare that all the data furnished above is true to the best of my knowledge.

Place: DELHI Yours truly

(C.SARAVANAN)



Contact this candidate