Laksh Jain
B.O.E e-Mail: ******.****@*****.***
B.Tech-Electrical Mobile: +91-839*******, +91-981******* Professional Synopsis:
• A Certified Boiler Operation Engineer by Directorate of Steam Boilers, Department of labour, Government of Maharashtra with 7 years 8 months of experience in Power Plant Operations.
• Presently working with M/s Lalitpur Power Generation Company Limited (3x660 MW), Lalitpur,Uttar Pradesh as Deputy Manager (O&M-operations) Since Sep-2015.
• Had worked with M/s Adani Power Maharashtra Limited, Tirora, Maharashtra (5x660 MW) as Assistant Manager (O&M-operations) from September 2011- September 2015. Experience Summary:
• Unit Controller & Strong functional knowledge of Desk operations.
• Conversant with various DCS viz Metso DNA, Foxboro (Invensys) DCS v10.2.2. Roles & Responsibilities:
• Experienced in handling day -to- day operations of power plant and deftly handling overall plant operation including BOP in capacity of Unit Controller.
• Proficiency in streamlining the working procedures (PTW) through SAP, preparing SOPs (Standard Operating Procedures) enhancing safe & reliable operations.
• Successfully handled restoration of power from black outs in minimum time possible and most of the emergencies thereby ensuring smooth flow of operations.
• Successfully handled the operation of power plant with safety and maximum PLF & availability, with focus on reduced APC, SOC & SHR.
• Participation in preparing SOPs for operation of turbine, boiler and their auxiliaries.
• Maintaining generation as per the requirement of grid according to availability based tariff..
• To oversee various operational parameters of the previous 24 hours and ensure proper response to any deviation or abnormalities.
• To follow up for recorded defects using SAP.
• Training of engineers and field operators about normal and abnormal operations in thermal power plant.
• To log all shift activities / events, important parameters and report to SCE.
• To provide data for preparation of Plant Daily Generation Report. Awards & Recognition:
• Awarded “Extra Miler Award” by Unit Head (L.P.G.C.L) for my contribution during hydrogen leakage from generator.
• Awarded “SPOT RECOGNITION” by PLANT HEAD (A.P.M.L) for saving the unit from tripping due to Primary air Fan Stalling
Professional Qualification:
• PGDC (Year of passing -2011) :
Passed 1 year Post Graduate Diploma In Thermal Power Plant Engineering from National Power Training Institute, Nangal (Punjab), with 76.14% marks.
• B.Tech ( Year of Passing -2010 ) :
Passed Electrical & Electronics Engineering from Kanpur Institute of Technology, Kanpur (U.P.) affiliated by Uttar Pradesh Technical University, Lucknow with 65.08% marks. Academic Qualifications:
• Intermediate ( Year of Passing – 2006 ) :
Passed Intermediate from CBSE Board, with 69.40% marks.
• High School ( Year of Passing – 2004 ) :
Passed High School from ICSE Board, with 68.67% marks. Professional Trainings:
• 12 days “Training of Trainers” program by Power sector skill council under Ministry of Power.
• Two weeks Simulator training at NPTI Faridabad on 500 MW simulator. Declaration:
I hereby declare that all the particulars provided by me are true to the best of my knowledge and belief. Date:
Place: (Laksh Jain)