SHAMSHAD AHMAD

Mobil no: 009***********

ac7lo1@r.postjobfree.com

Holding Valid UAE Driving License

Career Objective

Intend to build a career with leading corporate of high-tech involvement with committed and dedicated people who will help me to explore myself fully and realize my potential, willingly to work as key player in challenging and creative environment.

Academic Qualification

B. Tech in Electrical Engineering [ J.R.N. Rajasthan University]

DAE Electrical (Diploma of Associate Engineer) [AL-Kabir Polytechnic]

HSC Examination [Karim City College]

Matriculation Examination [Kabir Memorial High School]

Other Qualification

Auto Cad

Adobe Photoshop

Automation and Control System (PLC, Drive, SCADA)

Dan Foss drive training from Dubai

Fundamental and control and Integrated building management from Johnson control Dubai [UAE]

Profile Summary

As Electrical Supervisor total seventeen {17} years’ experience in manufacturing and utility industry having depth knowledge of Installation, testing, operation and maintenance work.

Professional Experience:

Company name: GRS, ACCIONA, GHELLA, Joint Venture Solar Power Plant [200MW]

Duration [2017 – 2018]- 1 Year’s

Jobs Responsibility:

Maintenance of Transformer, Inverter, DC Disconnector Switch, DC Box, Monitoring box, Trackers, PV modules, and all types of power and control panel.

Maintenance of CB and Switch gear.

Maintenance of PV Module

Testing of PV Module Strings (Voc).

IR Testing of DC cables.

Maintenance of T-Box and COM Box.

Executing the all work as per schematic drawing.

Depth knowledge of all types of electrical SLD

Professional Experience

Company name: Dubai Electricity and Water Authority

Duration: [14.12.2010 - 22.08.2017] - 7 Year’s

Designation: Sr. Electrical Supervisor

Jobs Responsibility:

Having working experience in Operation, Maintenance and Testing of 33/11 KV (DEWA) Substation

The following equipment covered under the Preventive, Corrective, and Routine Maintenance, Trouble Shooting and Testing:

Transformer – 80 MVA, 33/11kv.

Vacuum Circuit Breaker (Siemens) 33 KV, 2000Amps, Air circuit breaker

Double Break Isolator and its Operating Mechanism.

Current Transformer, Potential Transformer.

Auxiliary Transformer 63 KVA, 6600/440 Volts.

Lighting Transformer 25 KVA, 440/230 Volts.

Induction motor up to rating of 55 KW.

Maintenance of other auxiliaries like, LCDB, MCCB, PCC, MCC & other Low Voltage Electrical Systems.

I am familiar with the following testing sets used for testing of different electrical systems.

H.V Testing Set used to test the leakage of current at power frequency.

Primary Injection Set and secondary injection set.

Time Testing Set used to measure the closing and opening time of a breaker.

Contact Resistance Meter used to measure contact resistance between two contacts.

Leaking Current Analyzer used to measure Winding Resistance of a Transformer.

Winding Resistance Meter us1ed to measure Winding Resistance of a Transformer.

Turn Ratio Meter used to measure the Turn Ratio of a Transformer.

Having working knowledge of BD test of transformer.

Megger both motorized and hand-driven.

Earth Resistance Tester.

Working knowledge of complete Overhauling of Power Transformer and its accessories like, OLTC (On load tap changer), Buchholtz Relay, WTI, OTI Cooling Fan, Breather etc.

I am fully conversant in electrical safety system

Professional Experience

Company Name: Abu Dhabi Gas Liquefaction Company [ADGAD]

Duration [14.12.2006-18.10.2010] - 4 Year’s

Designation: Electrical supervisor

Jobs Responsibility:

I have working knowledge of Testing, Preventive, Corrective Maintenance and Fault finding and repair of following equipment Induction Motor rating up to 500 KW. (Siemens, Armstrong, TECO, York, ABB)Having working experience of Installation and Testing of Circuit Breaker – Air Circuit Breaker, Vacuum Circuit Breaker, rating up to 1600 Amps (ABB, TAMCO) Having working experience of Trouble Shooting and Maintenance of Automation and Controls Panel (PLC, DDC – FX Controller) Having sound knowledge of AC Drive Parameter setting and operation. I have sound knowledge of Electrical Drawings (Schematic, Single-Line and Control Drawings) Working knowledge of Electrical Side of Air Handling Units, Packaged Units, Chiller Units and other different centralized air conditioning systems. Operation, Maintenance and Trouble Shooting through Schematic and Control Diagram – MCC (Motor Control Center), PCC (Power Control Center), MDB (Main Distribution Board), LDB (Lighting Distribution Board) and JB (Junction Board).

Professional Experience

Company Name: Usha Martin . [Usha Alloys and Steel Division] -India

Duration : [05.10.2001- 08.11.2006]- 5 years

Designation: Electrical Engineer

Jobs Responsibility:

The following equipment covered under the Preventive, Routine and Corrective Maintenance, Trouble Shooting and Testing: Transformer – 150 MVA, Transformer 132/33. SF6 Circuit Breaker 132 KV, 2500Amp & 33KV, 200Amp Siemens, ABB make. Vacuum Circuit Breaker (Siemens) 33 KV, 2000Amps.Double Break Isolator and its Operating Mechanism. Current Transformer, Potential Transformer, Lightening Arrestor. Auxiliary Transformer 63 KVA, 6600/440 Volts. Lighting Transformer 25 KVA, 440/230 Volts . Induction Motor up to rating of 55 kw. Working knowledge of Testing of Current Transformer, Potential Transformer, Lightening Arrestor, SF6 Circuit Breaker, Vacuum Circuit Breaker, Air Circuit Breaker and Power Transformer. Maintenance of other auxiliaries like, LCDB, MCCB, PCC, MCC & other Low Voltage Electrical Systems. knowledge of Electrical Drawings (Schematic, Single-Line and Control Drawings)

Personal Information

Fathers Name : Late Abdul Aziz Khan

Date of Birth : 16/10/1976

Place of Birth : India, Jamshedpur [TATA]

Marital Status : Married

Religion : Muslim

Nationality : Indian

Passport No : N-1268756.

Declaration:

I hereby declare that the above stated information are true and correct to the best of my knowledge and belief.



Contact this candidate