SHUBHANKAR GHOSH (PGDC from NPTI/B.Tech - Electrical)
Contact Number: 075********/ 883-***-****
E-Mail: ac7b35@r.postjobfree.com, ac7b35@r.postjobfree.com
PLANT OPERATION AND PERFORMANCE
Total Experience-12 years
Presently associated with Essar Power MP Ltd., MP as Unit Controller in 1200 MW (2*600MW) PF fired power plant and designation is Manager.
Previously worked in Vedanta Aluminium Ltd at Jharsuguda and Lanjigarh in Operation as Shift incharge and Desk Engineer of 9*135MW CPP (PF fired) and 3*30 MW Co Generation Plant (PF Fired) respectively.
Organizational Experience
From year 2011 to Present:
Present responsibility is Unit Controller and reporting to Deputy GM and GM. The responsibility includes:
Unit Controlling of BTG from control room (Start up, Rolling, Loading, Shut down, Emergency Handling etc of 600 MW) including field activity monitoring.
Maintain the parameters within safe limits and optimise Auxiliary consumption upto design value.
Modification in various places for optimising process and saving cost of production.
Monitoring of daily operation and analysing the operation records of critical process parameters.
Regular monitoring of the plant heat rate and assessing the condition of unit and assessing the scope of improvement.
To ensure COC, Water chemistry, safety protections including fire, height and confined space checking.
To ensure proper recording of all operation related activities including DGR, Check List, Shift Routines, and PTW etc.
To ensure all defects are registered properly through SAP & liquidated on time.
Co-ordination with BOP (Fuel handling, Cooling Water Pump and Auxiliary boiler) area.
Grid Schedule maintaining and ensuring unit is on RGMO.
Coaching and maintaining safe environment in workplace.
From year 2007 to 2011:
In previous organisation, performed all Boiler, Turbine and Electrical system related desk operations in very smooth and safe way as shift in charge as well as desk operator:
Boiler desk related operation
Boiler light up and shutdown
Operation during emergency:
1.FD Fan, ID Fan, APH, PA Fan trip
2.Mill trip
3.Sudden decrease in boiler load
4.Tube failure
Routine checks
Turbo generator desk operation
Rolling and loading of turbine
Regular operation
Operation during emergency
Operation during Islanding
Synchronisation of generator
Planned shut down
Electrical system operation
System normalization after Black out
Load shedding operation during emergency
Others
Preparation of trip analysis report.
Permit issue through SAP by ensuring proper isolation and safety.
Guiding GETs about operation.
Appreciated & rewarded with bonus for achieving highest production.
Achieved successful and safe light up, rolling and planned shutdown each time.
Handled several emergencies keeping the required parameters unaffected in smooth and safe way as a desk engineer and as a shift in charge.
Arrange man power in different shifts.
Academic Qualifications
PGDC (Thermal Power Plant Engg) from of NATIONAL POWER TRANING INSTITUTE (E.R), Durgapur, passed in 2007, scored70%.
B.Tech (Electrical Engg) from West Bengal University of Technology, passed in 2006, scored 78%.
Training
1. Participated in 500 MW Simulator Training Course conducted by National Power Training Institute for 1 month in Feb 2007
2. Undergone two week project based training under C.E.T.E on micro controller in July 2005.
Software Knowledge
Conversant with Windows 8/7/Vista/XP, MS Office Applications (Word / Excel / PowerPoint) and E-Mail (Outlook 2013/2011/2010).
Personal Details
Date of Birth: 28th Sep 1983
Marital Status: Married (One Son)
Language: English, Hindi, Bengali
Father’s Name: Dr. Aloke Kumar Ghosh
Permanent Address: 140 B.K.Street, Sneha Apartment, Uttarpara, Dist-Hooghly (West Bengal), Pin- 712258
Passport: Available
Present CTC: Rs. 13,00,000 P.A