POSITION: RELAY TESTING ENGINEER
Experience Highlights: 3years 5months
OBJECTIVE:
Looking for a position to utilize my skills and abilities in a professional organization that offers professional growth while being resourceful, innovative and flexible.
AREAS OF EXPERTISE
Testing and commissioning of Control & Relay Panels for Transformer Protection, Line Distance Protection, Line Differential Protection, Busbar Protection, Feeder Protection Numerical Relay testing.
Configuration as per schematic diagram & Testing of Protective Relays for various needs.
Testing of accessories relays such as Over Load Relays, Thermal Over Load Relays, Check Synchronizing Relay, Definite Time Relay, Under Voltage Relay, Over voltage relay, Timer Relay, TCS relay.
Inspection of Control and Relay Panel, preparation of Test Report for sub- station, Power plant, and Process plant.
Schematics - DC Logics Checking (ABB, SIEMENS, BHEL, GE, L&T, etc.)
Ferrule verification and updating in As Built Drawing.
Good understanding, analysis and interpretation skills on Protection.
PROFESSIONAL DETAILS:
oB.E., Electrical and Electronics Engineering from Vins Christian college of Engineering with 7.23 CGPA(2010-2014).
PROJECTS:
400/220kV NTPC TANDA THERMAL PP:
oTesting & commissioning of 4 line bays, 2 Station transformers, 2 ICT, 2 Generating transformers with Bus bar protection.
PGCIL_220/132kV PURNEA SUBSTATION:
oTesting and Commissioning of line bays in 132kV.
oNTAMC Integration of 7 bays in 132kV.
BSPTCL_220/132kV PURNEA SUBSSTAION:
oTesting and Commissioning of line bays in 132kV.
PGCIL_400/220kV MAITHON SUBSTATION:
oNTAMC Integration of 3 bays in 400kV.
PGCIL_400/220kV MUZAFFARPUR SUBSTAION:
oNTAMC Integration of 3 bays in 400kV.
oNTAMC Integration of 2 bays in 220kV.
PGCIL_220/132kV SILIGURI SUBSTAION:
oNTAMC Integration of 7 bays in 132kV.
PGCIL_400/220kV BARIPADA SUBSTATION:
oNTAMC Integration of 6 bays in 400kV.
PGCIL_220/132kV BIRPARA SUBSTATION:
oNTAMC Integration of 5 bays in 132kV.
PGCIL_400/220kV GAYA SUBSTATION:
oNTAMC Integration of 2 bays in 220kV.
PGCIL_400/220kV KISHANGANJ SUBSTATION:
oNTAMC Integration of 4 bays in 220kV.
oSCADA signals configuration & Testing.
Factory Testing in Siemens India Pvt.Ltd. Goa.
Scheme checking & Corrections.
Testing of Control & Relay Panels (Transformer,Line,TBC,BC,TIE) 6.6kV to 765kV Substation.
Bay Interlocks checking, SCADA Signals testing.
Megger Test, HV test upto 2kV.
Software Handled
ABB -PCM600(UptoLatestversion2.8)
SCHNEIDER -MicomS1 Studio
ALSTOM -Micom S1 Agile
SIEMENS -DIGSI 4, DIGSI 5,Reyrolle.
Experience with ABB
REL670–Line Distance Protection
RED670–Line Differential Protection
Experience with Alstom
P444 –Line Distance Protection
P543–Line Differential Protection
Experience with SIEMENS
7SJ80X : Over Current Protection.
7VK6 : LBB relay.
7UT6X : Transformer Protection
7SA52 : Line Protection
7SJ6X : Multifunction Protection.
7SS52 : Bus bar protection.
6MD86, 6MD85 : Bay control unit.
7SD52 : Cable differential Protection.
7UM85 : Generator protection.
7SRXX : Over current & Differential Protection.
Test Kit Handled
OMICRON (CMC-256,CMC-356)
DOBLE F6150
PRESENT& PREVIOUS EMPLOYER
Period
Designation
Company Name
NOV 2014- to NOV-2015
Graduate Engineering Apprentices.
Avalon Technology Pvt Ltd.,Chennai.
JUNE 2016 TO Dec-2018
Relay Testing Engineer
Sun & Jay Engineering Pvt Ltd.,Chennai.
CERTIFICATION:
Diploma in Electrical CADD.
AutoCAD Electrical, AutoCAD 2D.
PERSONAL INFORMATION:
NAME :Senthilkumar.
DATE OF BIRTH :10.05.1993.
GENDER :Male.
LANGUAGES KNOWN :Tamil and English.
ADDRESS :C12/7, TNHB Colony,
Maharajanagar.
Tirunelveli.-627 011.
DECLARATION:
I hereby declare that all the particulars furnished above are true and correct to the best of my knowledge and belief.
Place: Yours Faithfully,
Date: (SENTHILKUMAR)