Post Job Free
Sign in

NDT INSPECTOR

Location:
Fereej Ibn Dirhem, Qatar
Posted:
January 14, 2019

Contact this candidate

Resume:

CURRICULUM VITAE

K. SURESH,

Killukkottai (Po),

Kulathur – Tk,

Pudukkottai – Dt. Mobile : +91-957*******

E.mail : ***********@*****.*** 0091 782-***-****

Objective:

To secure a career in Quality control and Assurance in a reputed organization, which appreciates professional approach and hard work, where I can utilize my knowledge, various skills & experience in contribution towards fulfilling the company’s growth objectives, develop my career and excel in the related field. Of Non-destructive testing technician.

QUALIFICATION:

Academic qualification : S.S.L.C

Technical qualification : DME

PROFESSIONAL QUALIFICATION:

ASNT Level II in, Ultrasonic Testing, Liquid Penetrant Testing, Magnetic Particles Testing, Radiographic Testing.

COMPUTER PROFICIENCY:

MS – Office (Word, Excel, Windows, Internet, Etc.)

SUMMARY

Over 12 years experiences in the field of Nondestructive Testing.

On-stream & Off-stream activity experience at RAS GAS

On-stream & Off-stream activity experience at DOLPHIN PROJECT

On-stream & Off-stream activity experience at QATAR GAS

On-stream & Off-stream activity experience at (ADCO) ASAP FFD PROJECT ABUDHABI .

On-stream & Off-stream activity experience at (ADCO) HABSAN PROJECT ABUDHABI .

On-stream & Off-stream activity experience at (QChem) Qatar Chemicals.

Knowledge about application of codes and standards like ASME sect. IX, sect. VIII, sect. V, AWS D1.1, ASME B31.3 and API 1104.

EQUIPMENTS HANDELED :

Ultrasonic Flaw Detectors : USM35a,USM25,USM-GO,Einstein IITFT,

SONATEST D20 & D50

Thickness Meters : PenametricDL26, DM4/DL/3/2E, DMS2.

Magnetic Yokes : MAGNA FLAX.

PT : Visible Method & Floruscent

Hardness : Krautkramer Mic – 10, ECOUTIP

PMI : Niton Analyzers, InnovXsystem

Boroscopic : Pearpoint - P340+ Flexiprobe

RT : Roll, Tech-ops 660, Spec-2T,Teltron,Delta 880

with Ir 192 SE 75 Isotope Source. X ray

(crawler&external) IPSI

SHUTDOWN EXPERIENCE:

COMPANY NAME : APPLUS VELOSI

CLIENT : QATAR CHEMICAL COMPANY

DESIGNATION : MULTI NDT TECHNICIAN, PMI & BOROSCOPY DURATION : FEB 1 st 2015 TO MARCH 3rd 2015 (30 DAYS)

COMPANY NAME : APPLUS VELOSI

CLIENT : QATAR CHEMICAL COMPANY

DESIGNATION : NDT INCHARGE

DURATION : JAN 21 st 2017 TO MARCH 11th 2017 (50 DAYS)

COMPANY NAME : ALMANSOORI INSPECTION SERVICES

CLIENT : ADMA-OPCO ZIRKU NORTH ARTIFICIAL ISLAD

DESIGNATION : NDT INSPECTOR

DURATION : OCTOBER 2017 TO DECEMBER 2017

Employment History

COMPANY NAME : FRONTIER CERTIFICATION INTERNATIONAL L.L.C

CLIENT : HAMAD PORT PROJECT QATAR

DESIGNATION : NDT INSPECTOR

DURATION : SEP 2018 TILL DATE

COMPANY NAME : NATIONAL INSPECTION SERVICES

CLIENT : BHEL

DESIGNATION : NDT INSPECTOR

DURATION : JAN 2018 TO AUG 2018

COMPANY NAME : APPLUS VELOSI

CLIENT : QATAR CHEMICAL COMPANY

DESIGNATION : MULTI NDT TECHNICIAN DURATION : APRIL 2014 TO MAY 2017

COMPANY NAME : LONESTAR TECHNICAL INSPECTION SERVICES. UAE,ABUDHABI CLIENT : ADCO.

DESIGNATION : SENIOR NDT INSPECTOR

DURATION : JULY 2010 to FEB 2013

COMPANY NAME : GB ENGINEERING INDIA CLIENT : BHEL

DESIGNATION : MULTI NDT TECHNICIAN DURATION : AUGUST 2009 to JUNE 2010

COMPANY NAME : SIEVERT INTERNATIONAL INSPECTION CO. Qatar

CLIENTS : RAS GAS QATAR GAS DOLPHIN

PROJECT QATAR PETROLEUM

DESIGNATION : MULTI NDT TECHNICIAN

DURATION : JUNE 2007 to June 2009

COMPANY NAME : SUPER QUALITY SERVICES CLIENT : BHEL

DESIGNATION : MULTI NDT TECHNICIAN DURATION : APRIL 2005 to JUNE 2007

ACTIVITIES PERFORMED

Carried out Inspection before and after Welding and Inspecting through Visual Test and NDT for Air Pre heaters, Heat Exchangers, Pipes, Tubes, Pressure Vessels and Windmill Towers.

UT Scanning for all pipelines, vessels and columns welding joints.

NDT documents review and radiography film interpretation and reporting.

Corrosion survey & thickness gauging of in-service piping systems & pressure vessels.

MPI & DPI of weld joints, instrument lines, crane & drilling equipments.

Visual inspection of vessels, storage tanks, pipe supports, & piping.

Computerized report preparations by using MS word, excel & power point.

Radiography testing of all butts welds of piping & plates.

MPI and DPI of welds & castings.

Performed UT MT, PT and RT Work on Vessels, Boiler Drums, Heat Exchanged column, Boilers Pipe lines interpretations of welding, Economizer coils, Super heater coils, and Various Pipelines Reactor heads.

Performed UT, MT, PT Work on Windmill Towers and Valve Bodies, Water wall panels for PUNJLLOYDS, DNV, NTPC, ENMAS, and BHEL.

Performed Radiographic Testing on required joints of piping line and ammonia plant, sulfuric plant and urea plant.

Performed Radiographic Testing on required on heavy steam line super heater coils, Economize Coils, Boiler Drums and mill towers circular

Performed Magnetic Particle Testing on Heavy Pressure vessels.

Carried out RT, UT, MT, PT for all Boiler Components.

NDT Inspection (RT, MT, PT) methods on welded parts, Boiler drums as per Customer Quality Plan.

Visual Inspection of Vessels, Storage tanks, Pipe Supports & piping.

Liquid Penetrant Testing and Magnetic Particle Testing in fabrication parts.

Carried out PT on weld joints, water panels, Bow nets and nuclear components.

UT thickness gauging of test separators, oil storage tanks, vessels, scrubbers and receivers.

UT grid scanning & pit mapping of pressure vessels & weak links for internal wall loss.

Performed Ultrasonic Testing on Piping and nozzles in petro chemical, oil and gas filled refinery Tie-rods.

Performed Ultrasonic Testing on piping in detection of correction, Erosion and pitting.

Performed ultrasonic in Piping and raw materials of tubular towers.

Performed ultrasonic scanning in Piping and inconnel material.

Welding

Carryout daily fit-up and weld visual inspection by coordinating with subcontractor inspectors according to the applicable WPS and relevant drawings and offering joints for NDT as per requirement.

Conducting and Reviewing all the NDT/PWHT/Hardness/PMI according to standards/specification.

Conduct line checking and punch list items prior to hydro testing as per P&ID, General Arrangement Drawing, Isometric drawing, and support specification/drawings.

Painting

Carryout inspection for WFT, DFT and surface finish for primer/intermediate coat/final coat applications and touch-up repairs and sign off the reports.

In-service Inspection

Attend pressure tests (hydro test, pneumatic test & helium test) for the process piping and various equipment (Heat exchangers, Pressure vessels etc.) based on the service integrity requirements.

Witnessing Calibration of Pressure Relieving Devices in and ensure proper overhauling, repair and Calibration and updating the master list, and checking the due for calibration periodically.

Carry outCorrosion monitoring inspectionswith Plant inspector at TML/CML, Deadlegs, stagnant lines, Injection points etc. and reviewing/verifying the results with base line readings and drawing/datasheet.

Thorough inspection to identify Corrosion under insulation (CUI) for piping/equipment at susceptible locations. Coordinate with insulation contractor to open damaged insulation areas & monitor insulation & cladding fix-back after thickness measurement.

Conducting the Boroscopic/Hardness/PMI according to standards/specification.

Thickness survey on the piping and storage tanks and make isometric drawing for piping on plant.

Reporting

Uploading Inspection reports (IR) and periodic thickness readings (TML/CML) to Inspection Management (IM) & Thickness Management (TM) in MERIDIUM.

PERSONAL PROFILE :

Date of Birth : 04.05.1985 Nationality : Indian Marital Status : Married

PASSPORT DETAILS :

Passport Number : N 4641418

Date of Issue : 18.11.2015

Date of Expiry : 17.11.2025

DECLARATION

I hereby declare that the information furnished above is true to the best of my knowledge and belief.

Date :

Place :

(K. SURESH)



Contact this candidate