B-Tech in EEE with 4 years of experience as a Testing and Commissioning Engineer
SUMMARY
Planning the site activities and implementing the project within the scheduled period of time.
Modification of drawings/ schemes as per the site requirement and preparing the as built drawings.
Functional checking of Switchgear panel, Control and Relay panels, ATS & MTS checking.
Leading the team with proper safety procedures.
Handling of test equipment’s such as Omicron CMC 356/353/256, Freja 300, CPC 300, Megger Insulation resistance Kit.
Calculation of settings for the numerical relays such as distance, differential protection relays.
Handling of relays software such as Micom S1 agile, Micom s1 studio, GE enervista, PCM 600, MRsuite.
Testing of numerical relays such as Feeder management, Distance, Differential, Auto reclosure, Sychronising check of various make (ALSTOM, GE, ABB, TAPCON-AVR)
SKILLS
Team liaison Self-motivated
Strong Communication Team leadership
Process Implementation
EMPLOYMENT DETAILS
Since Oct 2016:Mana S Al-Khamsan EST for Contracting, KSA as Testing & Commissioning Engineer, Electrical – Protection Department
Scheduling the activities and reporting the work progress to the client.
Scheme checking of switchgear panel, Control and protection panels for various voltage levels.
Modification of drawings and preparing the as built drawings
Visual inspection of switchgear panels.
Commissioning of power factor control panel.
ATS & MTS Checking
Testing of Energy meters Nexus and Landis + Gyr.
Configuring and testing of numerical protection relays.
May 2014 – Aug 2016: Grenel Powers Private Limited as Testing & Commissioning Engineer - Electrical
Planning and scheduling the work to be done.
Leading the team and guiding them to work with proper safety procedures.
Scheme checking of control and protection panels of various voltages levels 33/66/110/220/400/765KV substations.
Modification of drawings as per client requirement.
Troubleshooting the circuit of control and protection equipments.
Retrofitting of old relays with new numerical relays.
Calculation of settings for the numerical relays.
Configuring the numerical protection relays as per the approved drawing.
Testing of numerical protection relays such as Feeder management relays, Distance, Differential, Autoreclosure, Sychronising check relays.
KNOWLEGDE IN RELAYS
ALSTOM Relays: Transformer Protection Relay (P642, P643), Line Distance Protection Relay (P442, P444), Line Differential Protection Relay (P543, P546), Feeder Management Relay (P14N, P14D, P141, P142, P143), O/C & E/F Relay (P120, P122, P127, P111).
Schneider Relay: Distance Protection relay(P444), Feeder Management relay(VAMP)
Siemens Relays: Line Distance Protection (7SA62, 7SA52), Line Differential Protection (7SD60, 7SD61, 7SD80).
ABB Relays: Line Distance Protection (REL 670), Line Differential Protection (RED 670), Transformer Differential Protection (RET 670), Feeder Protection (REF 615)
GE Relays: Line Distance Protection Relay (D60, D30), Line Differential Protection Relay (L90), Generator protection relay (SR489).
ACADEMIC DETAILS
Bachelor of Technology (Electrical & Electronics Engineering) - SASTRA University, Tanjore completed at 2013 with 66.6%.
Higher Secondary education – Sri Ramakrishna Matric Hr Sec School, Perambalur completed at 2009 with 81.08%.
High school- Infant Jesus Matric Hr Sec School, Annavasal completed at 2007 with 62.02%.
PERSONAL DETAILS
Date of Birth : 02/05/1992
Languages Known : English, Tamil
Marital Status : Single
Projects Handled:
PROJECTS HANDLED IN KINGDOM OF SAUDI ARABIA
CLIENT
TIEPCO
LOCATION
DAMMAM INDUSTRIAL AREA 2, KSA
PROJECT
FACTORY TESTING
RESPONSIBILITIES – RELAY TESTING
Configuration and Testing of Feeder Protection relay( ABB-REF630, Schneider P142, GE-MIF1), Line Differential Relay(Schneider-P546, Siemens-7SD522, ABBRED670).
CLIENT
TIEPCO
LOCATION
BAISH, KSA
PROJECT
33KV/13.8KV SWITCHGEAR,
RESPONSIBILITIES – TESTING
Scheme check.
CT, PT Primary injection Test.
Testing of Feeder Protection Relay GE-MIF1
CLIENT
MEEDCO - HYUNDAI HEAVY INDUSTRIES LIMITED
LOCATION
AL-SAMIR, JEDDAH, KSA
PROJECT
380KV/110KV/13.8KV BSP, AL-SAMIR
RESPONSIBILITIES – TESTING AND COMMISSIONING
Scheme checking for 13.8KV ABTS panel
13.8KV Circuit breaker tripping and closing interlock checks.
Interface cable checks.
CLIENT
MA’ADEN WA’AD AL SHAMAL PHOSPHATE PROJECT
LOCATION
TURAIF, KSA
PROJECT
4.16KV/480V SUBSTATION, TURAIF
RESPONSIBILITIES – COMMISSIONING
MTS and ATS check
Commissioning of LV blockset panel
Commissioning of Profibus & Modbus communication
Modifications for Additional signal
Commissioning of Power factor control panel
CLIENT
G E
LOCATION
ALGASSIM, KSA
PROJECT
GACAAIRPORT UPGRADATION
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and Configuration of GE F650 & SR489
Circuit breaker tripping and closing interlock checks.
PROJECTS HANDLED IN INDIA
CLIENT
KPTCL(KARNATAKA POWER TRANSMISSION CORPORATION LIMITED)
LOCATION
MYLAR, KARNATAKA
PROJECT
110/33KV SUBSTATION, MYLAR
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of ALSTOM make Distance protection relay P442, Differential Protection relay P642 and REF Protection relay P141.
CLIENT
PONDICHERRY ELECTRICITY BOARD
LOCATION
KALAPAT, PONDICHERRY
PROJECT
33/11KV SUBSTATION, KALAPAT
RESPONSIBILITIES – RETROFITTING
Retrofitting and Commissioning of ALSTOM P14N relays
CLIENT
KPTCL(KARNATAKA POWER TRANSMISSION CORPORATION LIMITED)
LOCATION
DEVARAHIPPARAGI, KARNATAKA
PROJECT
110/33KV SUBSTATION, ATHARGA
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of ALSTOM make Over current and earth fault protection relay P141.
CLIENT
KPTCL(KARNATAKA POWER TRANSMISSION CORPORATION LIMITED)
LOCATION
BELGAUM, KARNATAKA
PROJECT
110/11KV SUBSTATION, BELGAUM
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of ALSTOM make Transformer Differential protection relays P643, Backup Over current and earth fault protection relay P141.
CLIENT
KPTCL(KARNATAKA POWER TRANSMISSION CORPORATION LIMITED)
LOCATION
BANGLORE, KARNATAKA
PROJECT
66/11KV SUBSTATION, JIGINI
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of ALSTOM make Line Differential protection relays P543, Backup Over current and earth fault protection relay P14D.
CLIENT
TS TRANSCO(TELANGANA STATE TRANSMISSION CORPORATION LIMITED)
LOCATION
VADAPALLI, TELANGANA
PROJECT
132/33KV SUBSTATION, VADAPALLI
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of ALSTOM make Distance protection relay P442, Backup Over current and earth fault Protection relay P14D.
CLIENT
KPCL(KARNATAKA POWER CORPORATION LIMITED)
LOCATION
RAICHUR, KARNATAKA
PROJECT
400/220KV SUBSTATION, RTPS(RAICHUR THERMAL POWER STATION)
RESPONSIBILITIES – RETROFITTING
Retrofitting the old relays with new Alstom make Distance Protection relay P444, Backup protection P143, Auxiliary tripping relays.
CLIENT
WBSETCL(WEST BENGAL STATE ELECTRICITY TRANSMISSION CORPORATION LTD)
LOCATION
SILLIGURI, WEST BENGAL
PROJECT
132/33KV SUBSTATION UJANI
RESPONSIBILITIES – TESTING AND COMMISSIONING
Testing and commissioning of Distance protection relays ALSTOM P442, Differential protection relays ALSTOM P642, Over current, Earth fault relays ALSTOM CDD, P141 and REF protection relays ALSTOM P141.
CLIENT
KPCL(KARNATAKA POWER CORPORATION LIMITED)
LOCATION
JOG, KARNATAKA
PROJECT
220KV SGS(SHARAVATHY GENERATING STATION)
RESPONSIBILITIES – RETROFITTING
Retrofitting the old relays with new Alstom make Distance Protection relay P444, Backup protection P141.
CLIENT
PGCIL(POWER GRID CORPORATION OF INDIA LIMITED)
LOCATION
GOOTY, ANDHRA PRADESH
PROJECT
400/220KV SUBSTATION, GOOTY
RESPONSIBILITIES – TESTING AND COMMISSIONING
Adaptation and Commissioning of new relays for automation system( NTAMC-National Transmission Asset Management Center)
CLIENT
PGCIL(POWER GRID CORPORATION OF INDIA LIMITED)
LOCATION
MEERUT, UTTAR PRADESH
PROJECT
765/400/220KV SUBSTATION, DAURALA
RESPONSIBILITIES – TESTING AND COMMISSIONING
Adaptation and Commissioning of new relays for automation system( NTAMC-National Transmission Asset Management Center)
CLIENT
PGCIL(POWER GRID CORPORATION OF INDIA LIMITED)
LOCATION
MYSORE,KARNATAKA
PROJECT
400/220KV SUBSTATION, MYSORE
RESPONSIBILITIES – TESTING AND COMMISSIONING
Adaptation and Commissioning of new relays for automation system( NTAMC-National Transmission Asset Management Center)