K. IYYAPPAN Mobile: +919*********
Ramapuram village E-mail_id:**********@*****.***
Madhurnthakam (Tk),
Kancheepuram (DT)-603201.
OBJECTIVE
To join an enterprise like yours so that it provides an opportunity for me to develop my engineering skills so that I can shine in my chosen field and to deliver my best to your company.
.
ACADEMIC
Bachelor of Engineering(EEE) with 6.3 CGPA from Adhiparasakthi College of Engineering, Kalavai, Anna University (2009 – 2012)
DIPLOMA.(EEE) with 74% from Adhiparasakathi polytechnic college, Melmaruvathur, (2008-2009)
HSC with 68%from Government Higher Secondary School, Vandavasi (2005-2006)
SSLC with 58.09% from Government Higher Secondary School, Vandavasi.(2003-2004)
SOFTWARE PROFICIENCY
AUTO CADD 2011
Packages: MS-office
Operating Systems: Windows XP, Windows 2007
AREA OF INTEREST
Power electronics
Protection and Switch Gear
Machines
PROJECT WORK
Title of the Project
Analysis And Design of Topological Structure For DC Solid state Circuit breaker
Domain
Electrical
Project Description
The aim of the project is to design a DC solid state circuit breaker(soft switching) without using mechanical circuit breaker(hard switching) in DC system. The proposed system makes full use of soft switching. The SSCB satisfy the requirements of fast Operation.
Components Used
Transformer, Step-down Transformer, Rectifier, Bridge rectifier, Voltage Regulator, SCR, Microcontroller, Hall effect current sensor, Liquid crystal display
ACHIEVEMENTS
Organizing secretary of the department.
One of the Organizers in college symposium.
Serviced as a student coordinator NSS in school days
TRAININGS UNDERGONE
Name of the Company
Place of Training
Tenure of Training
BHEL
Ranipet
one weeks in the month of December 2010
CAREER SUMMARY:
Over 5 years of professional experience in Electrical- Testing and Commissioning,
operation and Maintenance, in Power Plant, substations at various locations, GIS -Power system protection Relays and Control panels
WORKING EXPERIENCE IN BHAVINI
(Bharatiya Nabhikiya Vidyut Nigam LTD)-Kalpakam atomic energy
Working Experience in 500 Mega Watt atomic research plant 2013-2015
.
Working as Maintenance Engineer
MV Switchgear:
MV Breakers testing and commissioning
UAT (unit auxiliary transformer) Bus duct pre commissioning checks involved
6.6KV HT Breakers 3150A, 2500A, 1250A, Maintenance operating Work carried out.
Carried out Yearly preventive maintenance and testing of 6.6Kv VCB’s
Carried out Break down maintenance and Fault rectification of VCB’s, 6.6Kv Bus bar and connected HT motor loads.
Commissioning of feedback and commands from DGCP to SIP Panel and from SIP Panel to main control room panel
Panel wiring trouble shooting working 6.6kv Instrument chamber.
HTand LT Motors,BUSBAR and BUSDUCT
Involved in Stability testing and commissioning of HT motors
Pre Commissioning check in 10.7 MW Boiler feed pump motor.
Fuel core handling Robotic manipulator using LT motors pre Commissioning checks involved
HT and LT motors are take over the yearly preventive maintenance
Deficiency reports raised by Operation like not starting/tripping, protection logics, Relay problems were attended and cleared as soon as possible.
Carried out YPM checks on BUS BAR,and BUSDUCTS .
Daily log and Annual maintenance checklist preparation.
DIESEL GENERATOR SYNCHRONISATION AND MAINTENANCE AUXILIARIES:
The DG systems in 4x4.5 MVA,3.6 KVA 0.8 pf DG synchronization
Involved in yearly preventive maintenance of following equipments in four numbers of DG’s
LT Breakers
LT motors
Neutral grounding resistor panel
Phase side cubicle
Generator
Excitation Panels
Earthing panels
Revised and checked yearly preventive maintenance check list of DG system.
Numerical Relays and Meters: Carried out Calibration of Numerical relays testing for Feeder protection, Motor protection, Voltage protection, Alternator protection, Differential protection, Rotor earth fault protection relays
Working Experience 2015 August to 2017 April SBES Engineering Service's
Authorized for Schneider Electric
Working As a Testing and Service Engineer.
Service and testing Commissioning of
6.6Kv 11Kv and 33Kv.Breaker.
11KV and 6.6 Kv Breaker Retrofit and Testing Commissioning.
Customer complains we are Attend and terminate that problem in Various Place
Then all type of breakers service and spares changes in different make of breakers
VMX-type Breaker 78 nos Retrofit and commissioning at chennai,Hosur,Nagpoor ASHOK LEYLAND unit-1&2 plant.
VMX- HWX,PCOB,HVX_X, HWX-X type of Breaker yearly service and maintenance in our Client in KSEB,
DALMIYA CEMENT, JSW, NLC, Relaince,IOCL HLL Bhell, various location in overall south India .
Currently Working in
Name of the organization : VOLTECH Pvt ltd
Department : Operation & Maintenance.
Designation : Electrical maintenance Engineer
Location : Andrapradesh
Role and Responsibility:
220/33kv PSS Testing of Power Transformer, Circuit Breaker, Isolator, CTs, CVTs, Lighting Arrestor and
Earthing System.
Overall plant electrical equipment preventive maintenance work done
220kv substation operation maintenance work done
220/33kv - 80 MVA Power transformer yearly maintenance work done.
Monitoring and Controlling of SCADA operated 220/33 KV substation.
Operation & Maintenance of 220kV sub-station switchyard equipments, HT & LT equipments.
Responsible for handling the Preventive, and Breakdown maintenance.
Preparing generation and breakdown reports of Feeders
An effective team member with strong troubleshooting and problem solving of electrical and
Electronics parts of machine and utility of plant in engineering.
PERSONAL DETAILS
Full Name : K.Iyyappan
Date of Birth : 15th MAY 1989
Father’s Name : N.Kaniyappan
Mother’s Name : K.Jayanthi
Hobby : Swimming and listening music
Marital Status : Unmarried.
Languages Known : Tamil and English.
DECLARATION
I hereby declare that all the information mentioned above is true to the best of my knowledge.
Place:
Date: (K.IYYAPPAN)